Signal processing and uncertainty in an isothermal titration calorimeter

被引:12
|
作者
Rodriguez de Rivera, M. [1 ]
Socorro, F. [1 ]
机构
[1] Univ Las Palmas, Dept Fis, Las Palmas Gran Canaria 35017, Spain
关键词
calibration; isothermal titration calorimetry; liquid mixtures; uncertainty;
D O I
10.1007/s10973-006-8104-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, it is made a study of the accuracy of an isothermal titration calorimeter in the operating mode of 'continuous injection'. The experimental equipment has been a TAM2277-201/2250 by Thermometric AB and the liquid mixtures used in the calibration have been the mixture cyclohexane+benzene and the mixture water+ethanol. The calibration contemplates different effects that affect the uncertainty in the determination of the sensitivity, the effect of the liquid injection, the treatment of the calorimetric signal, the variation of the experimental baseline and the different noises included in the calorimetric signal.
引用
收藏
页码:745 / 750
页数:6
相关论文
共 50 条
  • [1] Signal processing and uncertainty in an isothermal titration calorimeter
    M. Rodríguez de Rivera
    F. Socorro
    Journal of Thermal Analysis and Calorimetry, 2007, 88 : 745 - 750
  • [2] AN ISOTHERMAL TITRATION CALORIMETER
    CHRISTENSEN, JJ
    JOHNSTON, HD
    IZATT, RM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1968, 39 (09): : 1356 - +
  • [3] ISOTHERMAL TITRATION CALORIMETER
    HAWKES, CM
    JANATA, J
    ANALYTICAL LETTERS, 1973, 6 (02) : 163 - 169
  • [4] ISOTHERMAL JACKET TITRATION CALORIMETER
    DANIELSSON, I
    SUNNER, S
    WADSO, I
    NELANDER, B
    ACTA CHEMICA SCANDINAVICA, 1964, 18 (04): : 995 - &
  • [5] Injection effect on the sensitivity in an isothermal titration calorimeter
    de Rivera, M. Rodriguez
    Socorro, F.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2006, 85 (02) : 477 - 479
  • [6] Injection effect on the sensitivity in an isothermal titration calorimeter
    M Rodríguez de Rivera
    F. Socorro
    Journal of Thermal Analysis and Calorimetry, 2006, 85 : 477 - 479
  • [7] A calibration method and algorithm implementation for isothermal titration calorimeter
    Ge X.
    Gao Y.
    Li D.
    Ge G.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2021, 42 (02): : 1 - 9
  • [8] Conditions for calibration of an isothermal titration calorimeter using chemical reactions
    Sgarlata, Carmelo
    Zito, Valeria
    Arena, Giuseppe
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (2-3) : 1085 - 1094
  • [9] Conditions for calibration of an isothermal titration calorimeter using chemical reactions
    Carmelo Sgarlata
    Valeria Zito
    Giuseppe Arena
    Analytical and Bioanalytical Chemistry, 2013, 405 : 1085 - 1094
  • [10] The association of anionic surfactants with β-cyclodextrin.: An isothermal titration calorimeter study
    Eli, WJ
    Chen, WH
    Xue, QJ
    JOURNAL OF CHEMICAL THERMODYNAMICS, 1999, 31 (10): : 1283 - 1296