Diagnostic Detection of Human Lung Cancer-Associated Antigen Using a Gold Nanoparticle-Based Electrochemical Immunosensor

被引:156
作者
Ho, Ja-an Annie [1 ]
Chang, Heng-Chia [1 ]
Shih, Neng-Yao [2 ]
Wu, Li-Chen [3 ]
Chang, Ying-Feng [4 ]
Chen, Chii-Chang [5 ]
Chou, Chien [4 ]
机构
[1] Natl Tsing Hua Univ, Dept Chem, BioAnalyt Lab, Hsinchu 300, Taiwan
[2] Natl Hlth Res Inst, Natl Inst Canc Res, Tainan 704, Taiwan
[3] Natl Chi Nan Univ, Dept Appl Chem, Biochem Lab, Nantou 545, Taiwan
[4] Natl Cent Univ, Dept Opt & Photon, Jhongli 320, Taiwan
[5] Natl Yang Ming Univ, Inst Biophoton, Taipei 112, Taiwan
关键词
NEURON-SPECIFIC ENOLASE; CEREBROSPINAL-FLUID; MASS-SPECTROMETRY; TUMOR-MARKER; HUMAN-SERUM; ASSAY; IDENTIFICATION; ENHANCEMENT; STABILITY; PROTEINS;
D O I
10.1021/ac1001959
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of rapid and sensitive methods for the detection of immunogenic tumor-associated antigen is important not only for understanding their roles in cancer immunology but also for the development of clinical diagnostics. a-Enolase (ENO1), a p48 molecule, is widely distributed in a variety of tissues, whereas gamma-enolase (ENO2) and beta-enolase (ENO3) are found exclusively in neuron/neuroendocrine and muscle tissues, respectively. Because ENO1 has been correlated with small cell lung cancer, nonsmall cell lung cancer, and head and neck cancer, it can be used as a potential diagnostic marker for lung cancer. In this study, we developed a simple, yet novel and sensitive, electrochemical sandwich immunosensor for the detection of ENO1; it operates through physisorption of anti-ENO1 monoclonal antibody on polyethylene glycol-modified disposable screen-printed electrode as the detection platform, with polyclonal secondary anti-ENO1-tagged, gold nanoparticle (AuNP) congregates as electrochemical signal probes. The immunorecognition of the sample ENO1 by the congregated AuNP@antibody occurred on the surface of the electrodes; the electrochemical signal from the bound AuNP congregates was obtained after oxidizing them in 0.1 M HCl at 1.2 V for 120 s, followed by the reduction of AuCl4- in square wave voltammetry (SWV) mode. The resulting sigmoidally shaped dose response curves possessed a linear dynamic working range from 10(-8) to 10(-12) g/mL. This AuNP congregate-based assay provides an amplification approach for detecting ENO1 at trace levels, leading to a detection limit as low as 11.9 fg (equivalent to 5 mu L of a 2.38 pg/mL solution).
引用
收藏
页码:5944 / 5950
页数:7
相关论文
共 36 条
[1]   Labeless Immunosensor Assay for the Stroke Marker Protein Neuron Specific Enolase Based upon an Alternating Current Impedance Protocol [J].
Barton, Andrew C. ;
Davis, Frank ;
Higson, Seamus P. J. .
ANALYTICAL CHEMISTRY, 2008, 80 (24) :9411-9416
[2]  
BLAEDEL WJ, 1978, ANAL CHEM, V50, P1026, DOI 10.1021/ac50030a008
[3]   An electrochemical metalloimmunoassay based on a colloidal gold label [J].
Dequaire, M ;
Degrand, C ;
Limoges, B .
ANALYTICAL CHEMISTRY, 2000, 72 (22) :5521-5528
[4]  
FUJITA K, 1987, CANCER-AM CANCER SOC, V60, P362, DOI 10.1002/1097-0142(19870801)60:3<362::AID-CNCR2820600313>3.0.CO
[5]  
2-U
[6]  
Hage DS, 1999, ANAL CHEM, V71, p294R
[7]  
Hasek J, 2006, Z KRISTALLOGR, P613
[8]   Proteomics-based identification of α-enolase as a tumor antigen in non-small lung cancer [J].
He, Ping ;
Naka, Tetsuji ;
Serada, Satoshi ;
Fujimoto, Minoru ;
Tanaka, Toshio ;
Hashimoto, Shoji ;
Shima, Yoshihito ;
Yamadori, Tomoki ;
Suzuki, Hidekazu ;
Hirashima, Tomonori ;
Matsui, Kaoru ;
Shiono, Hiroyuki ;
Okumura, Meinoshin ;
Nishida, Toshiro ;
Tachibana, Isao ;
Norioka, Naoko ;
Norioka, Shigemi ;
Kawase, Ichiro .
CANCER SCIENCE, 2007, 98 (08) :1234-1240
[9]  
Ho J.-A.A., 2008, J NANOSCI NANOTECHNO, V8, P1
[10]   Application of a liposomal bioluminescent label in the development of a flow injection immunoanalytical system [J].
Ho, JA ;
Huang, MR .
ANALYTICAL CHEMISTRY, 2005, 77 (11) :3431-3436