Assessment of sonographic venous peak systolic velocity in detecting hemodialysis arteriovenous graft stenosis

被引:6
作者
DeVita, MV
Ky, AJ
Fried, KO
Vogel, FE
Michelis, MF
机构
[1] Lenox Hill Hosp, Dept Med, Nephrol Sect, New York, NY 10021 USA
[2] Lenox Hill Hosp, Dept Surg, New York, NY 10021 USA
[3] Lenox Hill Hosp, Dept Radiol, New York, NY 10021 USA
关键词
peak systolic velocity (PSV); hemodialysis (HD) access;
D O I
10.1053/ajkd.2000.17669
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
There is no single effective means of assessing arteriovenous access function, although monitoring haemodialysis venous pressure (VP) or measuring access recirculation may be of some benefit. The present study assesses prospectively the efficacy of following the peak systolic velocity (PSV) as a single measure to detect arteriovenous graft (AVG) stenosis, PSV was measured in 12 patients after new AVG placement and at approximately 2-month intervals. Angiography was also performed after new graft placement and when PSV was elevated to greater than 200 cm/sec, hemodialysis access VP increased to greater than 150 mm Hg on three consecutive readings, or access recirculation increased to greater than 11%, PSV was then compared with results from angiography, VP monitoring, and access recirculation. The 12 patients underwent 34 PSV studies, followed by angiography on 25 occasions. Each patient underwent at least one angiogram, Each abnormal PSV value was confirmed with the finding of stenosis on angiogram, except for two patients with PSVs greater than 400 cm/sec and normal angiography results. VP and recirculation were not elevated. During this period, two patients developed thrombosis of the AVG, and two patients underwent angioplasty with improvement in PSV, We conclude that elevations in PSV measured at the venous anastomosis are an effective means of screening for AVG stenosis, AVG stenosis can occur early after AVG placement, and elevated VP and recirculation are late findings in AVG dysfunction. (C) 2000 by the National Kidney Foundation, Inc.
引用
收藏
页码:797 / 803
页数:7
相关论文
共 28 条
[1]  
[Anonymous], 1997, AM J KIDNEY DIS S, V30, pS160
[2]  
BAKER LD, 1976, T AM SOC ART INT ORG, V22, P382
[3]   PHYSICAL-EXAMINATION OF AV GRAFTS [J].
BEATHARD, GA .
SEMINARS IN DIALYSIS, 1992, 5 (01) :74-74
[4]  
BELL DD, 1988, ARCH SURG-CHICAGO, V123, P1169
[5]  
Besarab A, 1998, J AM SOC NEPHROL, V9, P284
[6]   CHRONIC HEMODIALYSIS USING VENIPUNCTURE AND A SURGICALLY CREATED ARTERIOVENOUS FISTULA [J].
BRESCIA, MJ ;
CIMINO, JE ;
APPEL, K ;
HURWICH, BJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1966, 275 (20) :1089-&
[7]   CORRELATION OF VENOGRAPHY, VENOUS-PRESSURE, AND HEMOACCESS FUNCTION [J].
CHOUDHURY, D ;
LEE, J ;
ELIVERA, HS ;
BALL, D ;
ROBERTS, AB ;
AHMED, Z .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1995, 25 (02) :269-275
[8]  
Dawson P, 1991, J Vasc Interv Radiol, V2, P125, DOI 10.1016/S1051-0443(91)72485-8
[9]   HEMODIALYSIS GRAFTS - COLOR DOPPLER FLOW IMAGING CORRELATED WITH DIGITAL SUBTRACTION ANGIOGRAPHY AND FUNCTIONAL STATUS [J].
DOUSSET, V ;
GRENIER, N ;
DOUWS, C ;
SENUITA, P ;
SASSOUSTE, G ;
ADA, L ;
POTAUX, L .
RADIOLOGY, 1991, 181 (01) :89-94
[10]   HEMODIALYSIS VASCULAR ACCESS MORBIDITY IN THE UNITED-STATES [J].
FELDMAN, HI ;
HELD, PJ ;
HUTCHINSON, JT ;
STOIBER, E ;
HARTIGAN, MF ;
BERLIN, JA .
KIDNEY INTERNATIONAL, 1993, 43 (05) :1091-1096