共 35 条
Accuracy and precision of manual segmentation of the maxillary sinus in MR images-a method study
被引:16
作者:
Andersen, Tobias N.
[1
,2
,3
]
Darvann, Tron A.
[2
,3
,4
]
Murakami, Shumei
[2
,3
,5
]
Larsen, Per
[2
,3
,5
]
Senda, Yurie
Bilde, Anders
[1
]
Buchwald, Christian V.
[1
]
Kreiborg, Sven
[2
,3
,5
,6
]
机构:
[1] Copenhagen Univ Hosp, Rigshosp, Dept Otorhinolaryngol Head & Neck Surg & Audiol, Copenhagen, Denmark
[2] Univ Copenhagen, Copenhagen Univ Hosp, Rigshosp, Craniofacial Image Res Lab 3D,Sch Dent, Copenhagen, Denmark
[3] Tech Univ Copenhagen, DTU Compute, Copenhagen, Denmark
[4] Copenhagen Univ Hosp, Rigshosp, Dept Oral & Maxillofacial Surg, Copenhagen, Denmark
[5] Osaka Univ, Grad Sch Dent, Dept Oral & Maxillofacial Radiol, Osaka, Japan
[6] Univ Copenhagen, Sch Dent, Dept Pediat Dent & Clin Genet, Copenhagen, Denmark
关键词:
CONE-BEAM CT;
PARANASAL SINUSES;
NASAL;
CHILDREN;
PNEUMATIZATION;
PREVALENCE;
D O I:
10.1259/bjr.20170663
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Objective: To assess the accuracy and precision of segmentation of the maxillary sinus in MR images to evaluate the potential usefulness of this modality in longitudinal studies of sinus development. Methods: A total of 15 healthy subjects who had been both craniofacial CT and MR scanned were included and the 30 maxillary sinus volumes were evaluated using segmentation. Two of the authors did segmentation of MRI and one of these authors did double segmentation. Agreement in results between CT and MRI as well as inter-and intraexaminer errors were evaluated by statistical and three-dimensional analysis. Results: The intraclass correlation coefficient for volume measurements for both method error, inter-and intraexaminer agreement were > 0.9 [maximal 95% confidence interval of 0.989-0.997, p < 0.001] and the limit of agreement for all parameters were < 5.1%. Segmentation errors were quantified in terms of overlap [Dice Coefficient (DICE) > 0.9 = excellent agreement] and border distance [95% percentile Hausdorff Distance (HD) < 2 mm = acceptableagreement]. The results were replicable and not influenced by systematic errors. Conclusion: We found a high accuracy and precision of manual segmentation of the maxillary sinus in MR images. The largest mean errors were found close to the orbit and the teeth. Advances in knowledge: MRI can be used for 3D models of the paranasal sinuses with equally good results as CT and allows longitudinal follow-up of sinus development.
引用
收藏
页数:7
相关论文