Strategy for Fabrication of Stable Tramadol Solid-Contact Ion-Selective Potentiometric Sensor Based on Polyaniline Nanoparticles

被引:36
|
作者
Elghobashy, Mohamed R. [1 ]
Mahmoud, Amr M. [1 ]
Rezk, Mamdouh R. [1 ]
El-Rahman, Mohamed K. Abd [1 ]
机构
[1] Cairo Univ, Fac Pharm, Dept Analyt Chem, ET-11562 Cairo, Egypt
关键词
ELECTRODES; LAYER;
D O I
10.1149/2.0161501jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A solid-state ion-selective electrode for detection of tramadol has been fabricated utilizing polyaniline nanoparticles as an ion-to-electron transducer layer. The polyaniline (PANI) nanoparticles were synthesized by the micellar emulsion chemical polymerization method and the mean particle size was similar to 8 nm. The inclusion of PANI nanoparticles as an ion-to-electron transducer layer between an ionophore-doped PVC membrane and solid contact electrodes was carried out to improve the stability of the electrical signal. Both short and long-term stability studies were performed and compared to PANI free electrodes. Furthermore, the electrode's stability at various pH levels was investigated. The formation of water at PANI/solid contact interface was studied. Results indicate an absence of the water layer at the interface. The PANI/solid contact electrodes had good piece-to-piece reproducibility and potential stability over 30 days. The fabricated electrodes were utilized for tramadol determination as a model pharmaceutical drug in the presence of all excipients; the linear range was 10(-6) to 10(-2) mol L-1, pH stability range was from 3-7 and the detection limit was calculated to be 3.9 x 10(-7) mol L-1. (C) 2014 The Electrochemical Society. All rights reserved.
引用
收藏
页码:H1 / H5
页数:5
相关论文
共 50 条
  • [31] Solid-contact ion-selective electrodes for aromatic cations based on π-coordinating soft carriers
    Bobacka, J
    Alaviuhkola, T
    Hietapelto, V
    Koskinen, H
    Lewenstam, A
    Lämsä, M
    Pursiainen, J
    Ivaska, A
    TALANTA, 2002, 58 (02) : 341 - 349
  • [32] Solid-Contact Ion-Selective Electrodes with Copper Hexacyanoferrate in the Transducer Layer
    V. V. Timofeev
    M. B. Levin
    A. A. Starikova
    M. A. Trofimov
    S. M. Korneev
    K. N. Mikhelson
    Russian Journal of Electrochemistry, 2018, 54 : 400 - 408
  • [33] Solid-Contact Ion-Selective Electrodes with Copper Hexacyanoferrate in the Transducer Layer
    Timofeev, V. V.
    Levin, M. B.
    Starikova, A. A.
    Trofimov, M. A.
    Korneev, S. M.
    Mikhelson, K. N.
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2018, 54 (04) : 400 - 408
  • [34] Stable Pb(II) ion-selective electrodes with a low detection limit using silver nanoparticles/polyaniline as the solid contact
    Zeng, Xianghua
    Jiang, Wenwen
    Waterhouse, Geoffrey I. N.
    Jiang, Xiaohui
    Zhang, Zhiming
    Yu, Liangmin
    MICROCHIMICA ACTA, 2021, 188 (11)
  • [35] Stable Pb(II) ion-selective electrodes with a low detection limit using silver nanoparticles/polyaniline as the solid contact
    Xianghua Zeng
    Wenwen Jiang
    Geoffrey I. N. Waterhouse
    Xiaohui Jiang
    Zhiming Zhang
    Liangmin Yu
    Microchimica Acta, 2021, 188
  • [36] Influence of phosphate buffer and proteins on the potentiometric response of a polymeric membrane-based solid-contact Pb(II) ion-selective electrode
    Joon, Narender Kumar
    He, Ning
    Wagner, Michal
    Cardenas, Marite
    Bobacka, Johan
    Lisak, Grzegorz
    ELECTROCHIMICA ACTA, 2017, 252 : 490 - 497
  • [37] Alternative coulometric signal readout based on a solid-contact ion-selective electrode for detection of nitrate
    Wang, Hemin
    Yuan, Baiqing
    Yin, Tanji
    Qin, Wei
    ANALYTICA CHIMICA ACTA, 2020, 1129 : 136 - 142
  • [38] Novel thallium(III) solid-contact ion-selective electrode with electropolymerized transducer
    Kharitonov, Sergey V.
    Zarembo, Yana V.
    Zarembo, Viktor I.
    ELECTROANALYSIS, 2006, 18 (13-14) : 1354 - 1362
  • [39] Selective and sensitive lead (II) solid-contact potentiometric sensor based on naphthalene-sulfonamide derivative
    A. Kamal
    R. Tejpal
    V. Bhalla
    M. Kumar
    R. K. Mahajan
    International Journal of Environmental Science and Technology, 2015, 12 : 2567 - 2578
  • [40] Elimination of undesirable water layers in solid-contact polymeric ion-selective electrodes
    Veder, Jean-Pierre
    De Marco, Roland
    Clarke, Graeme
    Chester, Ryan
    Nelson, Andrew
    Prince, Kathryn
    Pretsch, Erno
    Bakkert, Eric
    ANALYTICAL CHEMISTRY, 2008, 80 (17) : 6731 - 6740