A solid-state ion-selective electrode for detection of tramadol has been fabricated utilizing polyaniline nanoparticles as an ion-to-electron transducer layer. The polyaniline (PANI) nanoparticles were synthesized by the micellar emulsion chemical polymerization method and the mean particle size was similar to 8 nm. The inclusion of PANI nanoparticles as an ion-to-electron transducer layer between an ionophore-doped PVC membrane and solid contact electrodes was carried out to improve the stability of the electrical signal. Both short and long-term stability studies were performed and compared to PANI free electrodes. Furthermore, the electrode's stability at various pH levels was investigated. The formation of water at PANI/solid contact interface was studied. Results indicate an absence of the water layer at the interface. The PANI/solid contact electrodes had good piece-to-piece reproducibility and potential stability over 30 days. The fabricated electrodes were utilized for tramadol determination as a model pharmaceutical drug in the presence of all excipients; the linear range was 10(-6) to 10(-2) mol L-1, pH stability range was from 3-7 and the detection limit was calculated to be 3.9 x 10(-7) mol L-1. (C) 2014 The Electrochemical Society. All rights reserved.
引用
收藏
页码:H1 / H5
页数:5
相关论文
共 50 条
  • [21] Pulsed galvanostatic control of a solid-contact ion-selective electrode for potentiometric biosensing of microcystin-LR
    Yu, Nana
    Ding, Jiawang
    Wang, Wenwei
    Wang, Xuedong
    Qin, Wei
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 230 : 785 - 790
  • [22] Lead ion-selective polypyrrole solid-contact electrode based on crown ether
    Shim, Jihye
    Jang, Eun-Jung
    Chung, Koo-Chun
    ANALYTICAL LETTERS, 2007, 40 (16-18) : 3038 - 3049
  • [23] Recent advances in nanomaterial-based solid-contact ion-selective electrodes
    Mirabootalebi, Seyed Oveis
    Liu, Yang
    ANALYST, 2024, 149 (14) : 3694 - 3710
  • [24] Solid-contact potentiometric sensor for ascorbic acid based on cobalt phthalocyanine nanoparticles as ionophore
    Wang, K
    Xu, JJ
    Tang, KS
    Chen, HY
    TALANTA, 2005, 67 (04) : 798 - 805
  • [25] Solid-Contact Potentiometric Anion Sensing Based on Classic Silver/Silver Insoluble Salts Electrodes without Ion-Selective Membrane
    Liao, Chunxian
    Zhong, Lijie
    Tang, Yitian
    Sun, Zhonghui
    Lin, Kanglong
    Xu, Longbin
    Lyu, Yan
    He, Dequan
    He, Ying
    Ma, Yingming
    Bao, Yu
    Gan, Shiyu
    Niu, Li
    MEMBRANES, 2021, 11 (12)
  • [26] Transduction Mechanism of Carbon Nanotubes in Solid-Contact Ion-Selective Electrodes
    Crespo, Gaston A.
    Macho, Santiago
    Bobacka, Johan
    Rius, F. Xavier
    ANALYTICAL CHEMISTRY, 2009, 81 (02) : 676 - 681
  • [27] New Signal Readout Principle for Solid-Contact Ion-Selective Electrodes
    Vanamo, Ulriika
    Hupa, Elisa
    Yrjana, Ville
    Bobacka, Johan
    ANALYTICAL CHEMISTRY, 2016, 88 (08) : 4369 - 4374
  • [28] Ordered mesoporous carbon sphere-based solid-contact ion-selective electrodes
    Jiang, Zidengya
    Xi, Xin
    Qiu, Shi
    Wu, Dongqing
    Tang, Wei
    Guo, Xiaojun
    Su, Yuezeng
    Liu, Ruili
    JOURNAL OF MATERIALS SCIENCE, 2019, 54 (21) : 13674 - 13684
  • [29] Redox probe-based amperometric sensing for solid-contact ion-selective electrodes
    Sun, Xiaotong
    Yin, Tanji
    Zhang, Ziping
    Qin, Wei
    TALANTA, 2022, 239
  • [30] Ordered mesoporous carbon sphere-based solid-contact ion-selective electrodes
    Zidengya Jiang
    Xin Xi
    Shi Qiu
    Dongqing Wu
    Wei Tang
    Xiaojun Guo
    Yuezeng Su
    Ruili Liu
    Journal of Materials Science, 2019, 54 : 13674 - 13684