Strategy for Fabrication of Stable Tramadol Solid-Contact Ion-Selective Potentiometric Sensor Based on Polyaniline Nanoparticles

被引:39
作者
Elghobashy, Mohamed R. [1 ]
Mahmoud, Amr M. [1 ]
Rezk, Mamdouh R. [1 ]
El-Rahman, Mohamed K. Abd [1 ]
机构
[1] Cairo Univ, Fac Pharm, Dept Analyt Chem, ET-11562 Cairo, Egypt
关键词
ELECTRODES; LAYER;
D O I
10.1149/2.0161501jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A solid-state ion-selective electrode for detection of tramadol has been fabricated utilizing polyaniline nanoparticles as an ion-to-electron transducer layer. The polyaniline (PANI) nanoparticles were synthesized by the micellar emulsion chemical polymerization method and the mean particle size was similar to 8 nm. The inclusion of PANI nanoparticles as an ion-to-electron transducer layer between an ionophore-doped PVC membrane and solid contact electrodes was carried out to improve the stability of the electrical signal. Both short and long-term stability studies were performed and compared to PANI free electrodes. Furthermore, the electrode's stability at various pH levels was investigated. The formation of water at PANI/solid contact interface was studied. Results indicate an absence of the water layer at the interface. The PANI/solid contact electrodes had good piece-to-piece reproducibility and potential stability over 30 days. The fabricated electrodes were utilized for tramadol determination as a model pharmaceutical drug in the presence of all excipients; the linear range was 10(-6) to 10(-2) mol L-1, pH stability range was from 3-7 and the detection limit was calculated to be 3.9 x 10(-7) mol L-1. (C) 2014 The Electrochemical Society. All rights reserved.
引用
收藏
页码:H1 / H5
页数:5
相关论文
共 36 条
[1]   Kinetic spectrophotometric determination of tramadol hydrochloride in pharmaceutical formulation [J].
Abdellatef, HE .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 29 (05) :835-842
[2]  
Abu-Shawish A. H. M., 2010, PHARM ANAL ACTA, V1, P1
[3]   Improved determination of tramadol hydrochloride in biological fluids and pharmaceutical preparations utilizing a modified carbon paste electrode [J].
Abu-Shawish, Hazem M. ;
Abu Ghalwa, Nasser ;
Zaggout, Faried R. ;
Saadeh, Salman M. ;
Al-Dalou, Ayoub R. ;
Abou Assi, Anwar A. .
BIOCHEMICAL ENGINEERING JOURNAL, 2010, 48 (02) :237-245
[4]  
AG Z., 2003, LIHUA JIANYAN HUAX B, V39, P59
[5]  
[Anonymous], 2003, BRIT PHARMACOPOEIA, p[1868, A136]
[6]   Potentiometric sensors for trace-level analysis [J].
Bakker, E ;
Pretsch, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (03) :199-207
[7]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[8]   Potentiometric ion sensors [J].
Bobacka, Johan ;
Ivaska, Ari ;
Lewenstam, Andrzej .
CHEMICAL REVIEWS, 2008, 108 (02) :329-351
[9]  
Cao WD, 2002, ELECTROANAL, V14, P1571, DOI 10.1002/1521-4109(200211)14:22<1571::AID-ELAN1571>3.0.CO
[10]  
2-X