Strategy for Fabrication of Stable Tramadol Solid-Contact Ion-Selective Potentiometric Sensor Based on Polyaniline Nanoparticles

被引:36
|
作者
Elghobashy, Mohamed R. [1 ]
Mahmoud, Amr M. [1 ]
Rezk, Mamdouh R. [1 ]
El-Rahman, Mohamed K. Abd [1 ]
机构
[1] Cairo Univ, Fac Pharm, Dept Analyt Chem, ET-11562 Cairo, Egypt
关键词
ELECTRODES; LAYER;
D O I
10.1149/2.0161501jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A solid-state ion-selective electrode for detection of tramadol has been fabricated utilizing polyaniline nanoparticles as an ion-to-electron transducer layer. The polyaniline (PANI) nanoparticles were synthesized by the micellar emulsion chemical polymerization method and the mean particle size was similar to 8 nm. The inclusion of PANI nanoparticles as an ion-to-electron transducer layer between an ionophore-doped PVC membrane and solid contact electrodes was carried out to improve the stability of the electrical signal. Both short and long-term stability studies were performed and compared to PANI free electrodes. Furthermore, the electrode's stability at various pH levels was investigated. The formation of water at PANI/solid contact interface was studied. Results indicate an absence of the water layer at the interface. The PANI/solid contact electrodes had good piece-to-piece reproducibility and potential stability over 30 days. The fabricated electrodes were utilized for tramadol determination as a model pharmaceutical drug in the presence of all excipients; the linear range was 10(-6) to 10(-2) mol L-1, pH stability range was from 3-7 and the detection limit was calculated to be 3.9 x 10(-7) mol L-1. (C) 2014 The Electrochemical Society. All rights reserved.
引用
收藏
页码:H1 / H5
页数:5
相关论文
共 50 条
  • [1] Novel Solid-Contact Ion-Selective Microelectrodes for Localized Potentiometric Measurements
    Lamaka, Svetlana V.
    Taryba, Maryna G.
    Zheludkevich, Mikhail L.
    Ferreira, Mario G. S.
    ELECTROANALYSIS, 2009, 21 (22) : 2447 - 2453
  • [2] Solid-contact ion-selective electrodes for potentiometric determination of phenylethylamine in vitro
    Ma, Siyuan
    Wang, You
    Jiang, Lizi
    Hu, Ruifen
    Luo, Zhiyuan
    Li, Guang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (11)
  • [3] Solid-contact ion-selective electrode with stable internal electrode
    Vamvakaki, M
    Chaniotakis, NA
    ANALYTICA CHIMICA ACTA, 1996, 320 (01) : 53 - 61
  • [4] Microcavity based solid-contact ion-selective microelectrodes
    Sundfors, Fredrik
    Bereczki, Robert
    Bobacka, Johan
    Toth, Klara
    Ivaska, Ari
    Gyurcsanyi, Robert E.
    ELECTROANALYSIS, 2006, 18 (13-14) : 1372 - 1378
  • [5] Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva
    Urbanowicz, Marcin
    Sadowska, Kamila
    Pijanowska, Dorota G.
    Pomecko, Radoslaw
    Bochenska, Maria
    SENSORS, 2020, 20 (10)
  • [6] Calibration-free potentiometric sensing with solid-contact ion-selective electrodes
    Rousseau, Celeste R.
    Buhlmann, Philippe
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2021, 140
  • [7] Solid-contact bromide ion-selective electrode
    Stefanova, OK
    Alagova, ZS
    Khripun, GA
    RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 1995, 68 (08) : 1212 - 1213
  • [8] Solid-Contact Potentiometric Sensor Based on Polyaniline and Unsubstituted Pillar[5]Arene
    Stoikova, Ekaterina E.
    Sorvin, Michail I.
    Shurpik, Dmitry N.
    Budnikov, Herman C.
    Stoikov, Ivan I.
    Evtugyn, Gennady A.
    ELECTROANALYSIS, 2015, 27 (02) : 440 - 449
  • [9] Solid-Contact Ion-Selective Electrodes (ISEs) based on Ligand Functionalised Gold Nanoparticles
    Matzeu, Giusy
    Zuliani, Claudio
    Diamond, Dermot
    ELECTROCHIMICA ACTA, 2015, 159 : 158 - 165
  • [10] Potentiometric Determination of Dopamine Using a Solid-Contact Polymeric Membrane Ion-Selective Electrode
    Yin, Tanji
    Qin, Wei
    SENSOR LETTERS, 2013, 11 (03) : 607 - 612