Backscattered radiation into a transmission ionization chamber: Measurement and Monte Carlo simulation

被引:1
作者
Yoshizumi, Maira T. [1 ]
Yoriyaz, Helio [1 ]
Caldas, Linda V. E. [1 ]
机构
[1] CNEN, IPEN, BR-05508000 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Transmission ionization chamber; X-radiation; Backscattered radiation; Monte Carlo simulation; BEAM MONITOR CHAMBER; SCATTERED RADIATION; COLLIMATORS;
D O I
10.1016/j.apradiso.2009.10.015
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Backscattered radiation (BSR) from field-defining collimators can affect the response of a monitor chamber in X-radiation fields. This contribution must be considered since this kind of chamber is used to monitor the equipment response. In this work, the dependence of a transmission ionization chamber response on the aperture diameter of the collimators was studied experimentally and using a Monte Carlo (MC) technique. According to the results, the BSR increases the chamber response of over 4.0% in the case of a totally closed collimator and 50 kV energy beam, using both techniques. The results from Monte Carlo simulation confirm the validity of the simulated geometry. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:586 / 588
页数:3
相关论文
共 11 条
[1]  
[Anonymous], 2000, MCNP GEN MONTE CARLO, DOI DOI 10.1016/J.CCLET.2011.04.015
[2]   THE VALIDITY OF MONTE-CARLO SIMULATION IN STUDIES OF SCATTERED RADIATION IN DIAGNOSTIC-RADIOLOGY [J].
CHAN, HP ;
DOI, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (02) :109-129
[3]   BACKSCATTER DOSE PERTURBATION IN KILOVOLTAGE PHOTON BEAMS AT HIGH ATOMIC-NUMBER INTERFACES [J].
DAS, IJ ;
CHOPRA, KL .
MEDICAL PHYSICS, 1995, 22 (06) :767-773
[4]   BACKSCATTER INTO THE BEAM MONITOR CHAMBER - IMPLICATIONS FOR DOSIMETRY OF ASYMMETRIC COLLIMATORS [J].
DUZENLI, C ;
MCCLEAN, B ;
FIELD, C .
MEDICAL PHYSICS, 1993, 20 (02) :363-367
[5]   Monitor chamber backscatter for intensity modulated radiation therapy using multileaf collimators [J].
Hounsell, AR .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (02) :445-454
[6]  
*IAEA, 2002, CAL RAD PROT MON INS
[7]  
*IEC, 1994, 1627 IEC
[8]   Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations [J].
Jarry, Genevieve ;
Graham, Sean A. ;
Moseley, Douglas J. ;
Jaffray, David J. ;
Siewerdsen, Jeffrey H. ;
Verhaegen, Frank .
MEDICAL PHYSICS, 2006, 33 (11) :4320-4329
[9]   Modeling photon output caused by backscattered radiation into the monitor chamber from collimator jaws using a Monte Carlo technique [J].
Liu, HH ;
Mackie, TR ;
McCullough, EC .
MEDICAL PHYSICS, 2000, 27 (04) :737-744
[10]   MONTE-CARLO SIMULATION OF DIAGNOSTIC-X-RAY SCATTER [J].
PAPIN, PJ ;
RIELLY, PS .
MEDICAL PHYSICS, 1988, 15 (06) :909-914