Simultaneous molecular and anatomical imaging of the mouse in vivo

被引:67
作者
Goertzen, AL
Meadors, AK
Silverman, RW
Cherry, SR
机构
[1] Univ Calif Los Angeles, Crump Inst Mol Imaging, David Geffen Sch Med, Los Angeles, CA 90095 USA
[2] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
关键词
D O I
10.1088/0031-9155/47/24/301
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Non-invasive imaging technologies are opening up new windows into mouse biology. We have developed a mouse imaging system that integrates positron emission tomography (PET) with x-ray computed tomography (CT), allowing simultaneous anatomic and molecular imaging in vivo with the potential for precise registration of the two image volumes. The x-ray system consists of a compact mini-focal x-ray tube and an amorphous selenium flat panel x-ray detector with a low-noise CMOS readout. The PET system uses planar arrays of lutetium oxyorthosilicate scintillator coupled to position-sensitive photomultiplier tubes. We describe the design of this dual-modality imaging system and show, for the first time, simultaneously acquired PET and CT images in a phantom and in mice.
引用
收藏
页码:4315 / 4328
页数:14
相关论文
共 30 条
[1]   An integrated CMOS-selenium x-ray detector for digital mammography [J].
Andre, MP ;
Spivey, B ;
Martin, P ;
Morsell, L ;
Atlas, E ;
Pellegrino, T .
PHYSICS OF MEDICAL IMAGING, 1998, 3336 :204-209
[2]  
Beyer T, 2000, J NUCL MED, V41, P1369
[3]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .7. A TECHNIQUE TO REDUCE NOISE IN ACCIDENTAL COINCIDENCE MEASUREMENTS AND COINCIDENCE EFFICIENCY CALIBRATION [J].
CASEY, ME ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) :845-850
[4]   Detector development for microPET II:: a 1 μl resolution PET scanner for small animal imaging [J].
Chatziioannou, A ;
Tai, YC ;
Doshi, N ;
Cherry, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (11) :2899-2910
[5]   Principles of digital radiography with large-area, electronically readable detectors: A review of the basics [J].
Chotas, HG ;
Dobbins, JT ;
Ravin, CE .
RADIOLOGY, 1999, 210 (03) :595-599
[6]   Use of reporter genes for optical measurements of neoplastic disease in vivo [J].
Contag, CH ;
Jenkins, D ;
Contag, FR ;
Negrin, RS .
NEOPLASIA, 2000, 2 (1-2) :41-52
[7]  
Da Silva AJ, 2001, J NUCL MED, V42, P772
[8]   Exact and approximate rebinning algorithms for 3-D PET data [J].
Defrise, M ;
Kinahan, PE ;
Townsend, DW ;
Michel, C ;
Sibomana, M ;
Newport, DF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :145-158
[9]   Design and evaluation of an LSO PET detector for breast cancer imaging [J].
Doshi, NK ;
Shao, YP ;
Silverman, RW ;
Cherry, SR .
MEDICAL PHYSICS, 2000, 27 (07) :1535-1543
[10]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619