共 42 条
Effect of the duplex length on the sensing performance of a displacement-based electrochemical nucleic acid sensor with an adjustable point mutation discrimination function
被引:14
作者:
Li, Fengqin
[1
]
Xu, Yanmei
[1
]
Yu, Xiang
[2
]
Yu, Zhigang
[1
]
Ji, Hongrui
[1
]
Song, Yongbin
[1
]
Yan, Hong
[1
]
Zhang, Guiling
[1
]
机构:
[1] Harbin Univ Sci & Technol, Coll Chem & Environm Engn, Harbin 150040, Peoples R China
[2] Guangdong Univ Petrochem Technol, Coll Chem & Environm Engn, Maoming 525000, Peoples R China
基金:
中国国家自然科学基金;
关键词:
Electrochemical sensor;
Nucleic acid sequence;
Point mutation discrimination;
Methylene blue;
SEQUENCE-SPECIFIC DETECTION;
STEM-LOOP PROBE;
DNA SENSOR;
SENSITIVE DETECTION;
REAGENTLESS;
TARGET;
BIOSENSOR;
ASSAY;
AMPLIFICATION;
NANOPARTICLE;
D O I:
10.1016/j.snb.2016.05.025
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
One "signal on" electrochemical DNA sensing system was established based on the competitive displacement and hybridization-induced conformation change. This sensing system is composed of two probes, one linear capturing probe (CP) and one stem-loop signaling probe (SP) which are co-immobilized to the surface of Au electrode. Before adding target DNA, a 4-14 base-pair duplex formed between two probes forces the redox methylene blue (MB) far away from Au electrode surface, thereby producing low background current; after adding target DNA, the more stable duplex formed between CP and target DNA undoes the former duplex to release the SP. The released SP recovers the original stem-loop structure which drives MB close to the electrode surface, thereby producing high detection signal. The effect of the duplex length (DL) on sensing performance was systematically investigated. The research results show that the DL can pose a big effect on the signal enhancement (SE), the sensing response speed, the sensitivity and the specificity, further affecting the comprehensive performance of sensing system involved. Using the short DL, such as 4 or 6, the duplex is not rigid enough to support two strand probes well; using the long ones, such as 12 or 14, the stability of the duplex is so high that the displacement reaction is not easy to carry out. Using 10 DL, the best comprehensive performance can be obtained. Under the optimized conditions, a short designated 17-base sequence could be quantified over the ranges from 0.001 to 1 nM with a linear correlation of r(2) = 0.9953 and a limit of detection (LOD) was confirmed to be similar to 1 pM for the proposed sensor. When used for the analysis of point mutation target, the sensor also features an excellent discrimination ability and its good adjustability. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:648 / 657
页数:10
相关论文