System design for in vivo neutron activation analysis measurements of manganese in the human brain: based on Monte Carlo modeling

被引:15
作者
Arnold, ML [1 ]
McNeill, FE [1 ]
Prestwich, WV [1 ]
Chettle, DR [1 ]
机构
[1] McMaster Univ, Dept Phys & Astron, Med Phys & Radiat Sci Unit, Hamilton, ON L8S 4M1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
neutron activation analysis; manganese; in vivo; brain; Monte Carlo;
D O I
10.1016/S0969-8043(00)00199-8
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Manganese is an essential nutrient required by the human body, but conversely, over exposure to the element may cause central nervous system damage. The technique of in vivo neutron activation analysis, using the McMaster KN-accelerator, is being investigated as a possible method of noninvasively determining manganese concentrations within the human body. Since the brain is the primary target of damage from exposure it would be the ideal site for measurements. Thus, Monte Carlo simulations have been undertaken to define the optimum experimental parameters for such a measurement, examining the use of possible moderator, reflector and collimator materials. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:651 / 656
页数:6
相关论文
共 10 条
  • [1] Improvement of the prompt-gamma neutron activation facility at Brookhaven National Laboratory
    Dilmanian, FA
    Lidofsky, LJ
    Stamatelatos, I
    Kamen, Y
    Yasumura, S
    Vartsky, D
    Pierson, RN
    Weber, DA
    Moore, RI
    Ma, R
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (02) : 339 - 349
  • [2] Greger JL, 1999, NEUROTOXICOLOGY, V20, P205
  • [3] ICRP ( International Commission On Radiological Protection, 1975, 23 ICRP, V23
  • [4] LISKIEN H, 1975, NUCL DATA TABLES, V15, P57
  • [5] Total body-calcium measurements: comparison of two delayed-gamma neutron activation facilities
    Ma, R
    Ellis, KJ
    Yasumura, S
    Shypailo, RJ
    Pierson, RN
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (06) : N113 - N118
  • [6] Improvements to the in vivo measurement of cadmium in the kidney by neutron activation analysis
    McNeill, FE
    Chettle, DR
    [J]. APPLIED RADIATION AND ISOTOPES, 1998, 49 (5-6) : 699 - 700
  • [7] *NUCL DAT TABL, 1960, NUCL DAT TABL 3
  • [8] Pal PK, 1999, NEUROTOXICOLOGY, V20, P227
  • [9] SNYDER WS, 1969, J NUCL MED S, V3, P7
  • [10] ACCELERATOR-BASED EPITHERMAL NEUTRON BEAM DESIGN FOR NEUTRON-CAPTURE THERAPY
    YANCH, JC
    ZHOU, XL
    SHEFER, RE
    KLINKOWSTEIN, RE
    [J]. MEDICAL PHYSICS, 1992, 19 (03) : 709 - 721