Validity and reliability of Veloflex to measure active cervical range of motion in asymptomatic and symptomatic subjects

被引:7
作者
Canovas-Ambit, German [1 ]
Garcia-Vidal, Jose A. [1 ]
Martin-San Agustin, Rodrigo [2 ]
Dalla-Vecchia, Aurelio Arenas [3 ]
Sanchez-Barbadora, Mariana [2 ]
Medina-Mirapeix, Francesc [1 ]
机构
[1] Univ Murcia, Dept Physiotherapy, Murcia, Spain
[2] Univ Valencia, Dept Physiotherapy, Valencia, Spain
[3] Univ Murcia, Dept Electromagnetism & Elect, Murcia, Spain
关键词
Cervical; Range of motion; Validity/reliability; Optoelectronic device;
D O I
10.7717/peerj.11228
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Neck pain has a high annual incidence and decreases the cervical active range of motion (ROM). Clinicians use various methods to evaluate cervical range of motion (CROM) that some of them have also been proposed to give instant feedback. Accordingly, this study aimed to examine the validity and reliability of Veloflex (VF) to measure the CROM by comparison with the cervical range of motion (CROM) device, and to examine their test-retest reliability. Methods: Thirty-eight healthy and 20 symptomatic participants were evaluated. Cervical flexion-extension, side bending, and rotations were tested in two sessions, first by the CROM and VF and in the second only with the VF. To evaluate the concurrent validity and agreement between CROM and VF, Pearson correlation coefficient (r) and Bland-Altmann plots were used. Reliability were evaluated using intra-class correlation (ICC), standard error of measurement (SEM) and minimal detectable change (MDC). Results: CROM and VF showed excellent correlation for all movements (r > 0.960). Both devices provided small mean 'bias' (<= 1.29%) in all movements regarding CROM measures. The intra-rater and inter-rater reliability of the VF was excellent (ICC > 0.98). SEMs ranging from 0.72% to 2.38% and the MDC ranging from 1.22 degrees to 2.60 degrees in all participants. The results support the validity and reliability of VF to measure CROM. For its use, with a basic training is enough to get reliable measurements.
引用
收藏
页数:15
相关论文
共 47 条
[1]  
Abramson Joseph H, 2011, Epidemiol Perspect Innov, V8, P1, DOI 10.1186/1742-5573-8-1
[2]  
[Anonymous], 2015, Reliability. Health Measurement Scales: A practical guide to their development and use
[3]   Validity and Between-Day Reliability of the Cervical Range of Motion (CROM) Device [J].
Audette, Isabel ;
Dumas, Jean-Pierre ;
Cote, Julie N. ;
De Serres, Sophie J. .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2010, 40 (05) :318-323
[4]  
Blanpied Peter R, 2017, J Orthop Sports Phys Ther, V47, pA1, DOI 10.2519/jospt.2017.0302
[5]  
Brosseau L, 1997, Physiother Res Int, V2, P150
[6]   Intra- and intertester reliability and criterion validity of the parallelogram and universal goniometers for measuring maximum active knee flexion and extension of patients with knee restrictions [J].
Brosseau, L ;
Balmer, S ;
Tousignant, M ;
O'Sullivan, JP ;
Goudreault, C ;
Goudreault, M ;
Gringras, S .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2001, 82 (03) :396-402
[7]   Short-term effects of the traction-manipulation protocol in dizziness intensity and disability in cervicogenic dizziness: a randomized controlled trial [J].
Carrasco-Uribarren, Andoni ;
Rodriguez-Sanz, Jacobo ;
Lopez-de-Celis, Carles ;
Perez-Guillen, Silvia ;
Tricas-Moreno, Jose Miguel ;
Cabanillas-Barea, Sara .
DISABILITY AND REHABILITATION, 2022, 44 (14) :3601-3609
[8]   COMPARISON BETWEEN NECK PAIN DISABILITY AND CERVICAL RANGE OF MOTION IN PATIENTS WITH EPISODIC AND CHRONIC MIGRAINE: A CROSS-SECTIONAL STUDY [J].
Carvalho, Gabriela F. ;
Chaves, Thais C. ;
Goncalves, Maria C. ;
Florencio, Lidiane L. ;
Braz, Carolina A. ;
Dach, Fabiola ;
de Las Penas, Cesar Fernandez ;
Bevilaqua-Grossi, Debora .
JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2014, 37 (09) :641-646
[9]   Neck pain: Clinical practice guidelines linked to the international classification of functioning, disability, and health from the orthopaedic section of the American physical therapy association [J].
Childs, John D. ;
Cleland, Joshua A. ;
Elliott, James M. ;
Teyhen, Deydre S. ;
Wainner, Robert S. ;
Whitman, Julie M. ;
Sopky, Bernard J. ;
Godges, Joseph J. ;
Flynn, Timothy W. .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2008, 38 (09) :A1-A34
[10]   Validity and Responsiveness of the Visual Vertigo Analogue Scale [J].
Dannenbaum, Elizabeth ;
Chilingarian, Gevorg ;
Fung, Joyce .
JOURNAL OF NEUROLOGIC PHYSICAL THERAPY, 2019, 43 (02) :117-121