Endotracheal Intubation Comparing a Prototype Storz CMAC and a GlideScope Videolaryngoscope in a Medical Transport Helicopter - A Pilot Study

被引:7
作者
Boedeker, Ben H. [1 ,2 ,3 ,4 ]
Berg, Benjamin W. [5 ]
Bernhagen, Mary A. [4 ]
Murray, W. Bosseau [6 ]
机构
[1] Univ Nebraska Med Ctr, Dept Anesthesiol, 4101 Woolworth Ave, Omaha, NE 68105 USA
[2] Univ Nebraska Med Ctr, Omaha, NE USA
[3] TATRC, Fort Detrick, MD USA
[4] Omaha VA Med Ctr, Omaha, NE USA
[5] Univ Hawaii, John A Burns Sch Med, Honolulu, HI 96822 USA
[6] Penn State Univ, Coll Med, Simulat Dev Lab, Hershey, PA USA
来源
MEDICINE MEETS VIRTUAL REALITY 17 - NEXTMED: DESIGN FOR/THE WELL BEING | 2009年 / 142卷
关键词
Videolaryngoscopy; intubation; airway management; teaching; indirect laryngoscopy; virtual image; VIDEO LARYNGOSCOPE;
D O I
10.3233/978-1-58603-964-6-37
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this pilot study, experienced medical helicopter personnel evaluated and compared the prototype Storz CMAC and GlideScope (GS) videolaryngoscopes in intubating a Laerdal Difficult Airway Manikin in a helicopter. No significant differences were found between the devices in the standard airway mode with 100% success rates for the intubations. In the difficult airway mode, there was a significant difference (p = 0.03) between the Cormack Lehane scores observed with Direct View (DV) (3.75 +/- 0.46 - average +/- standard deviation) compared to the view with the prototype CMAC (2.25 +/- 0.71). The view was 3.00 +/- 0.76 with GS In the difficult airway, there were significantly more participants who obtained a Grade 1 or 2 view when using the CMAC compared to when using the Mac 3 blade (DV) (p = 0.025; Fisher Exact Probability Test). The success rate for intubating the difficult airway was 0% with DV; compared to 63% with the CMAC and 50 with the GS (p = 0.03). The participants answered a post study questionnaire regarding the characteristics of the devices and indicated preference for the CMAC over the GS in intubation of the difficult airway.
引用
收藏
页码:37 / +
页数:2
相关论文
共 6 条
[1]   An evaluation of the GlideScope®, a new video laryngoscope for difficult airways:: A manikin study [J].
Benjamin, F. J. ;
Boon, D. ;
French, R. A. .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (06) :517-521
[2]  
Boedeker BH, 2008, STUD HEALTH TECHNOL, V132, P31
[3]  
Boedeker B, 2007, STUD HEALTH TECHNOL, V125, P49
[4]   Seeing is believing: the importance of video laryngoscopy in teaching and in managing the difficult airway [J].
Kaplan, MB ;
Ward, D ;
Hagberg, CA ;
Berci, G ;
Hagiike, M .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (Suppl 2) :479-483
[5]   A new video laryngoscope - An aid to intubation and teaching [J].
Kaplan, MB ;
Ward, DS ;
Berci, G .
JOURNAL OF CLINICAL ANESTHESIA, 2002, 14 (08) :620-626
[6]   Comparison of the GlideScope® with the Macintosh laryngoscope for tracheal intubation in patients with simulated difficult airway [J].
Lim, Y ;
Yeo, SW .
ANAESTHESIA AND INTENSIVE CARE, 2005, 33 (02) :243-247