MR tagging of human lungs using hyperpolarized 3He gas

被引:50
作者
Owers-Bradley, JR
Fichele, S
Bennattayalah, A
McGloin, CJS
Bowtell, RW
Morgan, PS
Moody, AR
机构
[1] Univ Nottingham, Sch Phys & Astron, Nottingham NG7 2RD, England
[2] Queens Med Ctr, Dept Acad Radiol, Nottingham NG7 2UH, England
关键词
hyperpolarized He-3; tagging; lungs; diffusion; ventilation;
D O I
10.1002/jmri.10226
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the use of spin-tagging in conjunction with hyperpolarized gas imaging for monitoring lung 1 ventilation and gas diffusion. Methods and Materials: Images were taken at 0.15 T using single shot RARE, with hyperpolarized He-3 gas prepared by the metastability exchange technique. Sinusoidal modulation of the longitudinal magnetization (tag) was produced by two 90-degree rf pulses separated by a gradient pulse. The diffusion of He-3 gas in the lungs was measured by monitoring the decay of the tags. This study was conducted on a 25-year-old, male, healthy volunteer. Results: Clear tags in hyperpolarized He-3 gas both in vivo and in vitro were generated. The relative movement of the lung compared to a static, partial breath-hold was measured following inspiration or expiration. The diffusion coefficient of 3 He in the lungs was found to be 0.02 +/- 0.005 cm(2) seconds(-1). Conclusion: The spin-tagging of hyperpolarized He-3 in the lungs is possible, and allows regional lung movements to be measured following inspiration and expiration. It also allows quantification of the diffusion of the He-3 gas.
引用
收藏
页码:142 / 146
页数:5
相关论文
共 23 条
[1]   MR IMAGING OF MOTION WITH SPATIAL MODULATION OF MAGNETIZATION [J].
AXEL, L ;
DOUGHERTY, L .
RADIOLOGY, 1989, 171 (03) :841-845
[2]  
Chen Q, 2001, MAGNET RESON MED, V45, P24, DOI 10.1002/1522-2594(200101)45:1<24::AID-MRM1004>3.0.CO
[3]  
2-6
[4]  
Chen XJ, 1999, MAGN RESON MED, V42, P729, DOI 10.1002/(SICI)1522-2594(199910)42:4<729::AID-MRM15>3.0.CO
[5]  
2-2
[6]  
CHRONIK B, 2002, P 10 ANN M ISMRM HON
[7]   POLARIZATION OF HE3 GAS BY OPTICAL PUMPING [J].
COLEGROVE, FD ;
SCHEARER, LD ;
WALTERS, GK .
PHYSICAL REVIEW, 1963, 132 (06) :2561-&
[8]   Low-field He-3 nuclear magnetic resonance in human lungs [J].
Darrasse, L ;
Guillot, G ;
Nacher, PJ ;
Tastevin, G .
COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE II FASCICULE B-MECANIQUE PHYSIQUE CHIMIE ASTRONOMIE, 1997, 324 (11) :691-700
[9]   Quantification of regional intrapulmonary oxygen partial pressure evolution during apnea by 3He MRI [J].
Deninger, AJ ;
Eberle, B ;
Ebert, M ;
Grossmann, T ;
Heil, W ;
Kauczor, HU ;
Lauer, L ;
Markstaller, K ;
Otten, E ;
Schmiedeskamp, J ;
Schreiber, W ;
Surkau, R ;
Thelen, M ;
Weiler, N .
JOURNAL OF MAGNETIC RESONANCE, 1999, 141 (02) :207-216
[10]   CPMG measurements and ultrafast imaging in human lungs with hyperpolarized helium-3 at low field (0.1 T). [J].
Durand, E ;
Guillot, G ;
Darrasse, L ;
Tastevin, G ;
Nacher, PJ ;
Vignaud, A ;
Vattolo, D ;
Bittoun, J .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (01) :75-81