Design of a non-contact human body temperature measurement system

被引:0
|
作者
Deng, Xiaohong [1 ]
Su, Junhong [1 ]
机构
[1] Xian Technol Univ, Sch Optoelect Engn, Xian 710021, Shaanxi, Peoples R China
来源
FOURTH INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING | 2021年 / 11761卷
关键词
Human body temperature measurement system; sensor; microcontrollers; non-contact measurement;
D O I
10.1117/12.2586191
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This article uses AT89S51 single-chip microcomputer as the CPU of the human body temperature measurement system, uses the MLX90614 sensor to measure the body temperature, assists the use of the HC-SR04 ultrasonic module and the DS18B20 digital temperature sensor to measure the distance between the target and the system and the ambient temperature, and displays the temperature on the LCD system. It is suitable for non-contact measurement in public places, and can detect body temperature quickly and effectively with high accuracy.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Design of a Non-Contact Body Temperature Measurement System for Smart Campus
    Tang, Ho-Fai
    Hung, Kevin
    2016 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS-CHINA (ICCE-CHINA), 2016,
  • [2] Design of Non-contact measurement System
    Peng, Feng
    Wang, Zhuoer
    Peng, Bin
    Zheng, Liping
    2020 5TH INTERNATIONAL CONFERENCE ON MECHANICAL, CONTROL AND COMPUTER ENGINEERING (ICMCCE 2020), 2020, : 990 - 993
  • [3] Design of Non-contact Coordinate Measurement System
    Liu, Jingliang
    Pang, Chunchao
    Fang, Jianguo
    PROCEEDINGS OF THE 2015 6TH INTERNATIONAL CONFERENCE ON MANUFACTURING SCIENCE AND ENGINEERING, 2016, 32 : 1841 - 1844
  • [4] Non-contact temperature measurement
    Metallurgia, 1995, 62 (02):
  • [5] The design and realization of human body database management system based on non-contact 3D body measurement
    Pan, Li
    Yao, Tong
    Yao, Chong
    Wang, Jun
    ADVANCES IN TEXTILE ENGINEERING AND MATERIALS IV, 2014, 1048 : 545 - 549
  • [6] Non-contact temperature measurement
    不详
    INDUSTRIAL CERAMICS, 2001, 21 (01): : 56 - 56
  • [7] The Design and Implementation of a Non-contact Laser Measurement System
    ZHANG Ni ZHANG Yunwen LIU Weijun PU Xiongying China Agricultural University BeijingShenyang Institute of Automation Chinese Academy of SciencesShenyangChina
    微计算机信息, 2008, (22) : 7 - 9+162
  • [8] Development of Non-Contact Measurement System of Human Stepping
    Kurita, Koichi
    2008 PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-7, 2008, : 1031 - 1034
  • [9] Non-contact endoscopic temperature measurement
    Vilches, Sergio
    Ataman, Caglar
    Zappe, Hans
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XX, 2020, 11233
  • [10] Design And Development Of A Non-Contact Measurement System Applied For A Conveyor
    de Sousa, Joey Santos
    Silva, Francisco Hercules S.
    da Silva, Verilton Nunes
    Nobrega, Luiz Henrique Melo S.
    da Silva, Edleusom Saraiva
    Moreira, Jailton Ferreira
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 153 - 158