Designs and methods for interfacing SFC with MS

被引:41
作者
Tarafder, Abhijit [1 ]
机构
[1] Waters Corp, Milford, MA 01757 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2018年 / 1091卷
关键词
Supercritical fluid chromatography; Mass spectrometry; SFC-MS; Interfacing; Coupling; Mobile-phase; Solvent; Compressible; Expansion; SUPERCRITICAL-FLUID CHROMATOGRAPHY; PRESSURE CHEMICAL-IONIZATION; TANDEM MASS-SPECTROMETRY; ELECTROSPRAY-IONIZATION; KETAMINE METABOLITES; ISOPYCNIC PLOTS; CARBON-DIOXIDE; MOBILE-PHASE; PERFORMANCE; INJECTION;
D O I
10.1016/j.jchromb.2018.05.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hyphenating SFC with MS is now routinely performed in analytical laboratories. Major instrument providers supply commercial solutions for coupling SFC and MS, which has facilitated wider adoption of the technology. The current status, however, could be achieved based on the work done by many researchers over decades. Interfacing SFC with MS posed some unique challenges, compared to interfacing MS with LC or GC, demanding special solutions. Several interface designs were tried and tested over the years before suitable solutions could be detected. Additional measures, such as (a) mixing SFC mobile-phase with an additional liquid solvent at the column outlet, and (b) heating the interfacing device, had to be adopted to address some specific challenges. Although such modifications and measures look diverse, there is one factor that drove most of them - compressibility of SFC mobile-phase. There are two objectives of this review - (1) to compile various insights which were reported on describing and optimizing SFC-MS interfacing processes, and (2) to link these insights with the fundamental issue of solvent compressibility.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 44 条
[1]   Effects of liquid post-column addition in electrospray ionization performance in supercritical fluid chromatography-mass spectrometry [J].
Akbal, Laura ;
Hopfgartner, Gerard .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1517 :176-184
[2]   RECENT DEVELOPMENTS IN SUPERCRITICAL-FLUID CHROMATOGRAPHY MASS-SPECTROMETRY COUPLING [J].
ARPINO, PJ ;
HAAS, P .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :479-488
[3]   REVIEWS ON RECENT TRENDS IN CHROMATOGRAPHY MASS-SPECTROMETRY COUPLING .4. REASONS WHY SUPERCRITICAL FLUID CHROMATOGRAPHY IS NOT SO EASILY COUPLED WITH MASS-SPECTROMETRY AS ORIGINALLY ASSESSED [J].
ARPINO, PJ ;
SADOUN, F ;
VIRELIZIER, H .
CHROMATOGRAPHIA, 1993, 36 :283-288
[4]   SUPERCRITICAL FLUID CHROMATOGRAPHY-MASS SPECTROMETRY COUPLING [J].
ARPINO, PJ ;
COUSIN, J ;
HIGGINS, J .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1987, 6 (03) :69-73
[5]   MEASUREMENT OF SOLUBILITY IN SUPERCRITICAL FLUIDS USING CHROMATOGRAPHIC RETENTION - THE SOLUBILITY OF FLUORENE, PHENANTHRENE, AND PYRENE IN CARBON-DIOXIDE [J].
BARTLE, KD ;
CLIFFORD, AA ;
JAFAR, SA .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 1990, 35 (03) :355-360
[6]   RPLC-HILIC and SFC with Mass Spectrometry: Polarity-Extended Organic Molecule Screening in Environmental (Water) Samples [J].
Bieber, Stefan ;
Greco, Giorgia ;
Grosse, Sylvia ;
Letzel, Thomas .
ANALYTICAL CHEMISTRY, 2017, 89 (15) :7907-7914
[7]  
Borovcova L, 2018, J SEP SCI
[8]   Determination of pressure-temperature coordinates of liquid-vapor critical loci by supercritical fluid flow injection analysis [J].
Chester, TL .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1037 (1-2) :393-403
[9]   Pressure-regulating fluid interface and phase behavior considerations in the coupling of packed-column supercritical fluid chromatography with low-pressure detectors [J].
Chester, TL ;
Pinkston, JD .
JOURNAL OF CHROMATOGRAPHY A, 1998, 807 (02) :265-273
[10]   CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY WITH FLAME-IONIZATION DETECTION - REDUCTION OF DETECTION ARTIFACTS AND EXTENSION OF DETECTABLE MOLECULAR-WEIGHT RANGE [J].
CHESTER, TL .
JOURNAL OF CHROMATOGRAPHY, 1984, 299 (02) :424-431