Low voltage PWM inverter-fed motor insulation issues

被引:5
作者
Melfi, MJ [1 ]
机构
[1] Rockwell Automat, Richmond Hts, OH 44143 USA
来源
INDUSTRY APPLICATIONS SOCIETY 51ST ANNUAL PETROLEUM AND CHEMICAL INDUSTRY TECHNICAL CONFERENCE | 2004年
关键词
D O I
10.1109/PCICON.2004.1352790
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The topic of how low voltage IGBT-based PWM inverters create additional insulation stress through voltage reflections due to high dV/dt) has been documented for several years [1-5]. This paper first explains and summarizes the basic causes and effects of the high dV/dt environment. Second, the methodologies of various approaches to solutions are critically reviewed. Finally, standards (such as NEMA MG1, parts 30, 31) [6] have attempted to partially address this issue. However, there are still some areas which require important clarification. This paper makes the case for what can be done. to achieve the needed clarity. Testing of motor insulation systems to verify compliance with the proposed requirements is also covered.
引用
收藏
页码:137 / 142
页数:6
相关论文
共 6 条
[1]  
BELL S, 1996, IEEE PCIC C SEPT
[2]  
BONNETT AH, 1994, IEEE PULP P, P68
[3]  
MELFI M, 1997, IEEE IND APPL SOC C
[4]  
*NEMA, 2003, NEMA STANS PUBL MG, V1
[5]   TRANSIENT EFFECTS IN APPLICATION OF PWM INVERTERS TO INDUCTION-MOTORS [J].
PERSSON, E .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1992, 28 (05) :1095-1101
[6]  
SAUNDERS L, 1996, IEEE PCIC C SEPT