In Vivo 3-D Dose Verification Using PET/CT Images After Carbon-Ion Radiation Therapy

被引:4
作者
Sun, Lining [1 ,2 ]
Hu, Weigang [1 ,2 ]
Lai, Songtao [1 ,2 ]
Shi, Leijun [3 ]
Chen, Junchao [1 ,2 ]
机构
[1] Fudan Univ, Dept Radiat Oncol, Shanghai Canc Ctr, Shanghai, Peoples R China
[2] Fudan Univ, Shanghai Med Coll, Dept Oncol, Shanghai, Peoples R China
[3] Shanghai Proton & Heavy Ion Ctr, Dept Nucl Med, Shanghai, Peoples R China
来源
FRONTIERS IN ONCOLOGY | 2021年 / 11卷
关键词
carbon ion; radiation therapy; positron emission tomography; standard uptake value; dose verification; RANGE VERIFICATION; PROTON; BEAMS;
D O I
10.3389/fonc.2021.621394
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective To investigate the usefulness of positron emission tomography (PET) images obtained after carbon-ion irradiation for dose verification in carbon-ion radiotherapy. Methods and Materials An anthropomorphic head phantom was used in this study. Three cubes with volumes of 1, 4, and 10 ml were contoured as targets in the phantom CT through a treatment planning system. Treatment plans with six prescriptions from 2.5 to 10 Gy (2.5, 3, 5, 6, 8, and 10 Gy effective dose) were designed and delivered by 90 degrees fixed carbon-ion beams, respectively. After irradiation of the phantom, a PET/CT scan was performed to fuse the treatment-planning CT image with the PET/CT image. The relationship between target volume and the standard uptake value (SUV) in PET/CT was evaluated for corresponding plan prescription. The MIM Maestro software was used for the image fusion and data analysis. Results SUV in the target had an approximate linear relationship with the effective dose. The same effective dose could generate a roughly equal SUV for different target volumes (p < 0.05). Conclusions It is feasible to verify the actual 3-D dose distribution of carbon-ion radiotherapy by the approach in this study.
引用
收藏
页数:9
相关论文
共 19 条
  • [1] Comparing the biological washout of β+-activity induced in mice brain after 12C-ion and proton irradiation
    Ammar, C.
    Frey, K.
    Bauer, J.
    Melzig, C.
    Chiblak, S.
    Hildebrandt, M.
    Unholtz, D.
    Kurz, C.
    Brons, S.
    Debus, J.
    Abdollahi, A.
    Parodi, K.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (23) : 7229 - 7244
  • [2] Electronic portal imaging devices: a review and historical perspective of contemporary technologies and research
    Antonuk, LE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (06) : R31 - R65
  • [3] Extension and validation of an analytical model for in vivo PET verification of proton therapy-a phantom and clinical study
    Attanasi, F.
    Knopf, A.
    Parodi, K.
    Paganetti, H.
    Bortfeld, T.
    Rosso, V.
    Del Guerra, A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16) : 5079 - 5098
  • [4] Implementation and initial clinical experience of offline PET/CT-based verification of scanned carbon ion treatment
    Bauer, Julia
    Unholtz, Daniel
    Sommerer, Florian
    Kurz, Christopher
    Haberer, Thomas
    Herfarth, Klaus
    Welzel, Thomas
    Combs, Stephanie E.
    Debus, Juergen
    Parodi, Katia
    [J]. RADIOTHERAPY AND ONCOLOGY, 2013, 107 (02) : 218 - 226
  • [5] Usefulness of positron-emission tomographic images after proton therapy
    Hishikawa, Y
    Kagawa, K
    Murakami, M
    Sakai, H
    Akagi, T
    Abe, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05): : 1388 - 1391
  • [6] Positron camera for range verification of heavy-ion radiotherapy
    Iseki, Y
    Mizuno, H
    Futami, Y
    Tomitani, T
    Kanai, T
    Kanazawa, M
    Kitagawa, A
    Murakami, T
    Nishio, T
    Suda, M
    Urakabe, E
    Yunoki, A
    Sakai, H
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 515 (03) : 840 - 849
  • [7] Range verification methods in particle therapy: underlying physics and Monte Carlo modeling
    Kraan, Aafke Christine
    [J]. FRONTIERS IN ONCOLOGY, 2015, 5
  • [8] Initial clinical evaluation of PET-based ion beam therapy monitoring under consideration of organ motion
    Kurz, Christopher
    Bauer, Julia
    Unholtz, Daniel
    Richter, Daniel
    Herfarth, Klaus
    Debus, Juergen
    Parodi, Katia
    [J]. MEDICAL PHYSICS, 2016, 43 (02) : 975 - 982
  • [9] On-line monitoring of radiotherapy beams: Experimental results with proton beams
    Litzenberg, DW
    Roberts, DA
    Lee, MY
    Pham, K
    Molen, AMV
    Ronningen, R
    Becchetti, FD
    [J]. MEDICAL PHYSICS, 1999, 26 (06) : 992 - 1006
  • [10] Washout measurement of radioisotope implanted by radioactive beams in the rabbit
    Mizuno, H
    Tomitani, T
    Kanazawa, M
    Kitagawa, A
    Pawelke, J
    Iseki, Y
    Urakabe, E
    Suda, M
    Kawano, A
    Iritani, R
    Matsushita, S
    Inaniwa, T
    Nishio, T
    Furukawa, S
    Ando, K
    Nakamura, YK
    Kanai, T
    Ishii, K
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (15) : 2269 - 2281