Unsupervised pseudo CT generation using heterogenous multicentric CT/MR images and CycleGAN: Dosimetric assessment for 3D conformal radiotherapy

被引:23
|
作者
Jabbarpour, Amir [1 ]
Mahdavi, Seied Rabi [1 ,2 ]
Sadr, Alireza Vafaei [3 ,9 ,10 ]
Esmaili, Golbarg [4 ]
Shiri, Isaac [5 ]
Zaidi, Habib [5 ,6 ,7 ,8 ]
机构
[1] Iran Univ Med Sci, Sch Med, Med Phys Dept, Tehran, Iran
[2] Iran Univ Med Sci, Radiat Biol Res Ctr, Tehran, Iran
[3] RWTH Aachen Univ Hosp, Inst Pathol, Aachen, Germany
[4] Pars Hosp, Tehran, Iran
[5] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, CH-1211 Geneva 4, Switzerland
[6] Univ Geneva, Neuroctr, Geneva, Switzerland
[7] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[8] Univ Southern Denmark, Dept Nucl Med, Odense, Denmark
[9] Univ Geneva, Dept Theoret Phys, Geneva, Switzerland
[10] Univ Geneva, Ctr Astroparticle Phys, Geneva, Switzerland
基金
瑞士国家科学基金会;
关键词
MRI-Only radiotherapy; Brain tumors; Unsupervised deep learning; CycleGAN; RADIATION-THERAPY; MRI; REGISTRATION;
D O I
10.1016/j.compbiomed.2022.105277
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: Absorbed dose calculation in magnetic resonance-guided radiation therapy (MRgRT) is commonly based on pseudo CT (pCT) images. This study investigated the feasibility of unsupervised pCT generation from MRI using a cycle generative adversarial network (CycleGAN) and a heterogenous multicentric dataset. A dosimetric analysis in three-dimensional conformal radiotherapy (3DCRT) planning was also performed. Material and methods: Overall, 87 T1-weighted and 102 T2-weighted MR images alongside with their corre-sponding computed tomography (CT) images of brain cancer patients from multiple centers were used. Initially, images underwent a number of preprocessing steps, including rigid registration, novel CT Masker, N4 bias field correction, resampling, resizing, and rescaling. To overcome the gradient vanishing problem, residual blocks and mean squared error (MSE) loss function were utilized in the generator and in both networks (generator and discriminator), respectively. The CycleGAN was trained and validated using 70 T1 and 80 T2 randomly selected patients in an unsupervised manner. The remaining patients were used as a holdout test set to report final evaluation metrics. The generated pCTs were validated in the context of 3DCRT. Results: The CycleGAN model using masked T2 images achieved better performance with a mean absolute error (MAE) of 61.87 +/- 22.58 HU, peak signal to noise ratio (PSNR) of 27.05 +/- 2.25 (dB), and structural similarity index metric (SSIM) of 0.84 +/- 0.05 on the test dataset. T1-weighted MR images used for dosimetric assessment revealed a gamma index of 3%, 3 mm, 2%, 2 mm and 1%, 1 mm with acceptance criteria of 98.96%+/- 1.1%, 95% +/- 3.68%, 90.1% +/- 6.05%, respectively. The DVH differences between CTs and pCTs were within 2%. Conclusions: A promising pCT generation model capable of handling heterogenous multicenteric datasets was proposed. All MR sequences performed competitively with no significant difference in pCT generation. The proposed CT Masker proved promising in improving the model accuracy and robustness. There was no significant difference between using T1-weighted and T2-weighted MR images for pCT generation.
引用
收藏
页数:12
相关论文
共 29 条
  • [21] Comparison of 3D quantitative osteoarthritis imaging biomarkers from paired CT and MR images: data from the IMI-APPROACH study
    Alan Brett
    Michael A. Bowes
    Philip G. Conaghan
    BMC Musculoskeletal Disorders, 24
  • [22] Comparison of 3D quantitative osteoarthritis imaging biomarkers from paired CT and MR images: data from the IMI-APPROACH study
    Brett, Alan
    Bowes, Michael A.
    Conaghan, Philip G.
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [23] Automatic Detection of Brain Tumor from CT and MRI Images using Wireframe model and 3D Alex-Net
    Rani, Shilpa
    Kumar, Sandeep
    Ghai, Deepika
    Prasad, K. M. V. V.
    2022 INTERNATIONAL CONFERENCE ON DECISION AID SCIENCES AND APPLICATIONS (DASA), 2022, : 1132 - 1138
  • [24] Organ at Risk Segmentation in Head and Neck CT Images Using a Two-Stage Segmentation Framework Based on 3D U-Net
    Wang, Yueyue
    Zhao, Liang
    Wang, Manning
    Song, Zhijian
    IEEE ACCESS, 2019, 7 : 144591 - 144602
  • [25] The 3D CT superimposition method using image fusion based on the maximum mutual information algorithm for the assessment of oral and maxillofacial surgery treatment results
    Lee, Jee-Ho
    Kim, Myung-Jin
    Kim, Soung-Min
    Kwon, Oh-Hyung
    Kim, Yong-Kyeom
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2012, 114 (02): : 167 - 174
  • [26] A pilot study in the 3D registration of structured-light facial data with spiral CT images of the facial defect A structured-light surface and spiral CT images have been superimposed successfully for the first time to create an accurate and complete 3D virtual head model of the facial defect with underlying skeletal structure using the registration method
    Qiu, Jing
    Sun, Jian
    Xiong, Yao-Yang
    Gu, Xiao-Yu
    Xi, Jun-Tong
    Zhang, Fu-Qiang
    VIRTUAL AND PHYSICAL PROTOTYPING, 2011, 6 (03) : 149 - 156
  • [27] 3D Oxygen-Enhanced MRI at 3T MR System: Comparison With Thin-Section CT of Quantitative Capability for Pulmonary Functional Loss Assessment and Clinical Stage Classification of COPD in Smokers
    Ohno, Yoshiharu
    Yui, Masao
    Yoshikawa, Takeshi
    Seki, Shinichiro
    Takenaka, Daisuke
    Kassai, Yoshimori
    Hattori, Hidekazu
    Murayama, Kazuhiro
    Toyama, Hiroshi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (04) : 1042 - 1051
  • [28] Quantification of liver-Lung shunt fraction on 3D SPECT/CT images for selective internal radiation therapy of liver cancer using CNN-based segmentations and non-rigid registration
    Luu, Manh Ha
    Mai, Hong Son
    Pham, Xuan Loc
    Le, Quoc Anh
    Le, Quoc Khanh
    van Walsum, Theo
    Le, Ngoc Ha
    Franklin, Daniel
    Le, Vu Ha
    Moelker, Adriaan
    Chu, Duc Trinh
    Trung, Nguyen Linh
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 233
  • [29] The Minimal Ablative Margin of Radiofrequency Ablation of Hepatocellular Carcinoma (> 2 and < 5 cm) Needed to Prevent Local Tumor Progression: 3D Quantitative Assessment Using CT Image Fusion
    Kim, Young-sun
    Lee, Won Jae
    Rhim, Hyunchul
    Lim, Hyo K.
    Choi, Dongil
    Lee, Ji Young
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 758 - 765