Effect of dissolved oxygen content on pin-on-disc wear Behavior of biomedical Co-Cr-Mo alloys in a like-on-like configuration in distilled water

被引:4
|
作者
Kumagai, Kazushige [1 ]
Nomura, Naoyuki
Chiba, Akihiko
机构
[1] Iwate Univ, Ctr Reg Collaborat Res & Educ, Morioka, Iwate 0208551, Japan
[2] Iwate Univ, Fac Engn, Dept Welfare Engn, Morioka, Iwate 0208551, Japan
[3] Tohoku Univ, Inst Mat Res, Sendai, Miyagi 9808557, Japan
关键词
biomaterial; medical implants; cobalt-chromium-molybdenum alloy; wear; wear behavior; wear mechanism; pin-on-disc; metal-on-metal; adhesion; oxidation; three-body abrasion;
D O I
10.2320/matertrans.MRA2007601
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The wear behavior of a forged Co-29Cr-6Mo alloy without any Ni and C added has been investigated by using a tribosystem consisting of a pin-on-disc type wear testing machine in distilled water containing different dissolved oxygen content. Dissolved oxygen content in the distilled water was controlled by aerating with oxygen or by deaerating with argon. Wear volume in the distilled water containing high oxygen content is approximately two times larger than in that containing low oxygen content. Accordingly, it is deduced that the overall wear volume is significantly affected by the dissolved oxygen content in the distilled water surrounding the tribosystem. Although abrasive wear, caused by wear debris, is operative as a wear mechanism in the present tribosystem irrespective of oxygen content, the transfer of the wear debris to sliding surfaces, as well its the aggregation of the wear debris on the sliding Surfaces, is more prone to occur during the wear process with the lower oxygen content. Therefore, in the present tribosystem with the lower oxygen content, since the transfer of the wear debris to the disc or the pin readily occurs, the generation of the wear debris does not directly contribute to the wear volume, leading to the apparently lower wear volume in the tribosystem with lower oxygen content than in that with higher oxygen content; the transfer of the wear debris is not counted as wear loss because the wear volume is estimated based on the loss in disc and pin weight that occurs during the wear test.
引用
收藏
页码:1511 / 1516
页数:6
相关论文
共 4 条
  • [1] Pin-on-disk wear behavior in a like-on-like configuration in a biological environment of high carbon cast and low carbon forged Co-29Cr-6Mo alloys
    Chiba, Akihiko
    Kumagai, Kazushige
    Nomura, Naoyuki
    Miyakawa, Satoru
    ACTA MATERIALIA, 2007, 55 (04) : 1309 - 1318
  • [2] Effects of Precipitates and Albumin in Simulated Body Fluids on Pin-on-Disk Wear Behavior of Biomedical Co-Cr-Mo Alloys
    Ueda, Kyosuke
    Kasamatsu, Motoka
    Tanno, Masanori
    Ueki, Kosuke
    Geringer, Jean
    Narushima, Takayuki
    MATERIALS TRANSACTIONS, 2016, 57 (12) : 2054 - 2059
  • [3] Mass Loss and Ion Elution of Biomedical Co-Cr-Mo Alloys during Pin-on-Disk Wear Tests
    Ueda, Kyosuke
    Nakaie, Kaori
    Namba, Shigenobu
    Yoneda, Takashi
    Ishimizu, Keita
    Narushima, Takayuki
    MATERIALS TRANSACTIONS, 2013, 54 (08) : 1281 - 1287
  • [4] Effect of Mo content on the passivation and localized corrosion behavior of laser engineered net shaped (LENS) Co-Cr-Mo alloys in a simulated physiological solution
    Narayanan, Deeparekha
    Liu, Michael
    Martinez, Alan
    Brooks, Ryan
    Kuttolamadom, Mathew
    Castaneda, Homero
    ADDITIVE MANUFACTURING, 2023, 77