Magnetic ionic liquid-based dispersive liquid-liquid microextraction technique for preconcentration and ultra-trace determination of Cd in honey

被引:33
作者
Fiorentini, Emiliano F. [1 ]
Escudero, Leticia B. [1 ]
Wuilloud, Rodolfo G. [1 ]
机构
[1] Univ Nacl Cuyo, Inst Interdisciplinario Ciencias Basicas ICB, Fac Ciencias Exactas & Nat, Lab Analyt Chem Res & Dev QUIANID,UNCUYO CONICET, Padre J Contreras 1300, RA-5500 Mendoza, Argentina
关键词
Magnetic ionic liquids; Microextraction; Preconcentration; Cadmium; Honey; ATOMIC-ABSORPTION-SPECTROMETRY; PHASE MICROEXTRACTION; WATER SAMPLES; CADMIUM; LEAD; EXTRACTION; SOLVENTS; BEHAVIOR; PB;
D O I
10.1007/s00216-018-1050-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, highly efficient, batch, and centrifuge-less dispersive liquid-liquid microextraction method based on a magnetic ionic liquid (MIL-DLLME) and electrothermal atomic absorption spectrometry (ETAAS) detection was developed for ultra-trace Cd determination in honey. Initially, Cd(II) was chelated with ammonium diethyldithiophosphate (DDTP) at pH 0.5 followed by its extraction with the MIL trihexyl(tetradecyl)phosphonium tetrachloroferrate(III) ([P-6,P-6,P-6,P-14]FeCl4) and acetonitrile as dispersant. The MIL phase containing the analyte was separated from the aqueous phase using only a magnet. A back-extraction procedure was applied to recover Cd from the MIL phase using diluted HNO3 and this solution was directly injected into the graphite furnace of ETAAS instrument. An extraction efficiency of 93% and a sensitivity enhancement factor of 112 were obtained under optimal experimental conditions. The detection limit (LOD) was 0.4 ng L-1 Cd, while the relative standard deviation (RSD) was 3.8% (at 2 mu g L-1 Cd and n = 10), calculated from the peak height of absorbance signals. This work reports the first application of the MIL [P-6,P-6,P-6,P-14]FeCl4 along with the DLLME technique for the successful determination of Cd at trace levels in different honey samples.
引用
收藏
页码:4715 / 4723
页数:9
相关论文
共 30 条
[1]  
[Anonymous], 1972, WHO TECHNICAL REPORT, P32
[2]   Magnetomotive room temperature dicationic ionic liquid: A new concept toward centrifuge-less dispersive liquid-liquid microextraction [J].
Beiraghi, Asadollah ;
Shokri, Masood ;
Seidi, Shahram ;
Godajdar, Bijan Mombani .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1376 :1-8
[3]   Selective determination of inorganic cobalt in nutritional supplements by ultrasound-assisted temperature-controlled ionic liquid dispersive liquid phase microextraction and electrothermal atomic absorption spectrometry [J].
Berton, Paula ;
Martinis, Estefania M. ;
Martinez, Luis D. ;
Wuilloud, Rodolfo G. .
ANALYTICA CHIMICA ACTA, 2012, 713 :56-62
[4]   Hollow fiber liquid-phase microextraction of cadmium(II) using an ionic liquid as the extractant [J].
Chen, Hui ;
Han, Juan ;
Wang, Yun ;
Hu, Yutao ;
Ni, Liang ;
Liu, Yingying ;
Kang, Wenbing ;
Liu, Yan .
MICROCHIMICA ACTA, 2014, 181 (11-12) :1455-1461
[5]   Extraction of DNA by Magnetic Ionic Liquids: Tunable Solvents for Rapid and Selective DNA Analysis [J].
Clark, Kevin D. ;
Nacham, Omprakash ;
Yu, Honglian ;
Li, Tianhao ;
Yamsek, Melissa M. ;
Ronning, Donald R. ;
Anderson, Jared L. .
ANALYTICAL CHEMISTRY, 2015, 87 (03) :1552-1559
[6]   Structure and magnetic behavior of transition metal based ionic liquids [J].
Del Sesto, Rico E. ;
McCleskey, T. Mark ;
Burrell, Anthony K. ;
Baker, Gary A. ;
Thompson, Joe D. ;
Scott, Brian L. ;
Wilkes, John S. ;
Williams, Peg .
CHEMICAL COMMUNICATIONS, 2008, (04) :447-449
[7]   Geographical discrimination of Italian honey by multi-element analysis with a chemometric approach [J].
Di Bella, Giuseppa ;
Lo Turco, Vincenzo ;
Potorti, Angela Giorgia ;
Bua, Giuseppe Daniel ;
Fede, Maria Rita ;
Dugo, Giacomo .
JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2015, 44 :25-35
[8]   Comparison of palladium-magnesium nitrate and ammonium dihydrogenphosphate modifiers for cadmium determination in honey samples by electrothermal atomic absorption spectrometry [J].
García, JCR ;
García, JB ;
Latorre, CH ;
Rodríguez, MF ;
Martín, SG ;
Crecente, RMP .
TALANTA, 2003, 61 (04) :509-517
[9]   Dispersive liquid-liquid microextraction combined with graphite furnace atomic absorption spectrometry - Ultra trace determination of cadmium in water samples [J].
Jahromi, Elham Zeini ;
Bidari, Araz ;
Assadi, Yaghoub ;
Hosseini, Mohammad Reza Milani ;
Jamali, Mohammad Reza .
ANALYTICA CHIMICA ACTA, 2007, 585 (02) :305-311
[10]  
Khammas Z. A. A., 2012, International Journal of Chemical Sciences, V10, P1185