Automated planning of breast radiotherapy using cone beam CT imaging

被引:16
作者
Amit, Guy [1 ]
Purdie, Thomas G. [1 ,2 ,3 ]
机构
[1] Princess Margaret Canc Ctr, Radiat Med Program, Toronto, ON M5G 2M9, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5S 3E2, Canada
[3] Univ Toronto, Univ Hlth Network, Techna Inst, Toronto, ON M5G 1P5, Canada
关键词
cone-beam computed tomography; breast cancer; radiotherapy planning; automation; image processing; COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; REGISTRATION; FEASIBILITY; ENHANCEMENT; QUALITY;
D O I
10.1118/1.4905111
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Develop and clinically validate a methodology for using cone beam computed tomography (CBCT) imaging in an automated treatment planning framework for breast IMRT. Methods: A technique for intensity correction of CBCT images was developed and evaluated. The technique is based on histogram matching of CBCT image sets, using information from "similar" planning CT image sets from a database of paired CBCT and CT image sets (n = 38). Automated treatment plans were generated for a testing subset (n = 15) on the planning CT and the corrected CBCT. The plans generated on the corrected CBCT were compared to the CT-based plans in terms of beam parameters, dosimetric indices, and dose distributions. Results: The corrected CBCT images showed considerable similarity to their corresponding planning CTs (average mutual information 1.0 +/- 0.1, average sum of absolute differences 185 +/- 38). The automated CBCT-based plans were clinically acceptable, as well as equivalent to the CT-based plans with average gantry angle difference of 0.99 degrees +/- 1.1 degrees, target volume overlap index (Dice) of 0.89 +/- 0.04 although with slightly higher maximum target doses (4482 +/- 90 vs 4560 +/- 84, P < 0.05). Gamma index analysis (3%, 3 mm) showed that the CBCT-based plans had the same dose distribution as plans calculated with the same beams on the registered planning CTs (average gamma index 0.12 +/- 0.04, gamma < 1 in 99.4% +/- 0.3%). Conclusions: The proposed method demonstrates the potential for a clinically feasible and efficient online adaptive breast IMRT planning method based on CBCT imaging, integrating automation. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:770 / 779
页数:10
相关论文
共 34 条
[1]   Feasibility of CBCT-based dose calculation: Comparative analysis of HU adjustment techniques [J].
Fotina, Irina ;
Hopfgartner, Johannes ;
Stock, Markus ;
Steininger, Thomas ;
Luetgendorf-Caucig, Carola ;
Georg, Dietmar .
RADIOTHERAPY AND ONCOLOGY, 2012, 104 (02) :249-256
[2]  
Gonzalez R.C., 2002, Digital Image Processing, V2nd
[3]   Three-dimensional multimodal brain warping using the demons algorithm and adaptive intensity corrections [J].
Guimond, A ;
Roche, A ;
Ayache, N ;
Meunier, J .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (01) :58-69
[4]   Cone beam computerized tomography: the effect of calibration of the Hounsfield unit number to electron density on dose calculation accuracy for adaptive radiation therapy [J].
Hatton, Joan ;
McCurdy, Boyd ;
Greer, Peter B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (15) :N329-N346
[5]   DETERMINING OPTICAL-FLOW [J].
HORN, BKP ;
SCHUNCK, BG .
ARTIFICIAL INTELLIGENCE, 1981, 17 (1-3) :185-203
[6]   Deformable planning CT to cone-beam CT image registration in head-and-neck cancer [J].
Hou, Jidong ;
Guerrero, Mariana ;
Chen, Wenjuan ;
D'Souza, Warren D. .
MEDICAL PHYSICS, 2011, 38 (04) :2088-2094
[7]   Adaptive radiation therapy for breast IMRT-simultaneously integrated boost: Three-year clinical experience [J].
Hurkmans, Coen W. ;
Dijckmans, Ingrid ;
Reijnen, Miranda ;
van der Leer, Jorien ;
van Vliet-Vroegindeweij, Corine ;
van der Sangen, Maurice .
RADIOTHERAPY AND ONCOLOGY, 2012, 103 (02) :183-187
[8]   Flat-panel cone-beam computed tomography for image-guided radiation therapy [J].
Jaffray, DA ;
Siewerdsen, JH ;
Wong, JW ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1337-1349
[9]   Inter-fraction motion and dosimetric consequences during breast intensity-modulated radiotherapy (IMRT) [J].
Jain, Popja ;
Marchant, Tom ;
Green, Melanie ;
Watkins, Gillian ;
Davies, Julie ;
McCarthy, Claire ;
Loncaster, Juliette ;
Stewart, Alan ;
Magee, Brian ;
Moore, Christopher ;
Price, Pat .
RADIOTHERAPY AND ONCOLOGY, 2009, 90 (01) :93-98
[10]   Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations [J].
Jarry, Genevieve ;
Graham, Sean A. ;
Moseley, Douglas J. ;
Jaffray, David J. ;
Siewerdsen, Jeffrey H. ;
Verhaegen, Frank .
MEDICAL PHYSICS, 2006, 33 (11) :4320-4329