Does standing limb alignment after total knee arthroplasty predict dynamic alignment and knee loading during gait?

被引:29
作者
Riviere, Charles [1 ]
Ollivier, Matthieu [2 ]
Girerd, Damien [2 ]
Argenson, Jean Noel [2 ]
Parratte, Sebastien [2 ]
机构
[1] Imperial Coll London, Charing Cross Hosp, MSK Lab, Fulham Palace Rd, London W6 8RF, England
[2] Univ Aix Marseille, Hop St Marguerite, Serv Chirurg Orthoped, 270 Blvd St Marguerite, F-13009 Marseille, France
关键词
TKA; Alignment; HKA; Gait analysis; MECHANICAL AXIS ALIGNMENT; MEASURED IN-VIVO; PLANE; REPLACEMENTS; PROTOCOLS; SURVIVAL; JOINT;
D O I
10.1016/j.knee.2017.03.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A principle of MA is to achieve a neutral standing coronal alignment of the limb (HKA angle) to reduce risks of implant loosening, reduce polyethylene wear, and optimize patellar tracking. Several long-term studies have questioned this because the relationship between alignment and implant survivorship is weaker than previously reported. We hypothesize that standing HKA poorly predicts implant failure because it does not predict dynamic HKA, dynamic adduction moment, and loading of the knee during gait. Therefore, the aim of our study is to assess the relationship between the standing and the dynamic (gait activity) HKAs. Methods: A prospective study on a cohort of 35 patients treated with a posterior-stabilized TKA for primary osteoarthritis. Three months after surgery each patient had a long-leg radiograph and the limb was classified as neutrally aligned (17 patients), varus aligned (nine patients), or valgus aligned (four patients). Patients then performed a gait analysis for level walking. Results: Standing HKA has a moderate correlation with the peak dynamic varus (r = 0.318, p = 0.001) and the mean and peak adduction moments (r = 031 and r = -0.352 respectively). No significant correlation between standing HKA and the mean dynamic coronal alignment (r = 0.14, p = 0.449). No differences were found for dynamic frontal parameters (dynamic HKA and adduction moment) between patients defined as neutrally or varus aligned. Conclusions: The standing HKA after MA was of little value to predict dynamic behaviour of the limb during gait, this may explain why standing coronal alignment after TKA may have limited influence on long-term implant fixation and wear. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:627 / 633
页数:7
相关论文
共 26 条
[1]   Coronal alignment in total knee replacement HISTORICAL REVIEW, CONTEMPORARY ANALYSIS, AND FUTURE DIRECTION [J].
Abdel, M. P. ;
Oussedik, S. ;
Parratte, S. ;
Lustig, S. ;
Haddad, F. S. .
BONE & JOINT JOURNAL, 2014, 96B (07) :857-862
[2]   Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Zurakowski, D ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05) :682-687
[3]   Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo [J].
Benoit, Daniel L. ;
Ramsey, Dan K. ;
Lamontagne, Mario ;
Xu, Lanyi ;
Wretenberg, Per ;
Renstrom, Per .
GAIT & POSTURE, 2006, 24 (02) :152-164
[4]   The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years [J].
Bonner, T. J. ;
Eardley, W. G. P. ;
Patterson, P. ;
Gregg, P. J. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (09) :1217-1222
[5]   Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty [J].
Collier, Matthew B. ;
Engh, C. Anderson, Jr. ;
McAuley, James P. ;
Engh, Gerard A. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (06) :1306-1314
[6]  
Deep K, 2015, FRONT SURG, V2, DOI [10.3389/fsurg.2015.00062, 10.3389/tsurg.2C15.CC0G2]
[7]   Quantitative comparison of five current protocols in gait analysis [J].
Ferrari, Alberto ;
Benedetti, Maria Grazia ;
Pavan, Esteban ;
Frigo, Carlo ;
Bettinelli, Dario ;
Rabuffetti, Marco ;
Crenna, Paolo ;
Leardini, Alberto .
GAIT & POSTURE, 2008, 28 (02) :207-216
[8]   Influence of Limb Alignment on Mediolateral Loading in Total Knee Replacement [J].
Halder, Andreas ;
Kutzner, Ines ;
Graichen, Friedmar ;
Heinlein, Bernd ;
Beier, Alexander ;
Bergmann, Georg .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (11) :1023-1029
[9]   No influence of coronal laxity and alignment on lift-off after well-balanced and aligned total knee arthroplasty [J].
Hamai, Satoshi ;
Miura, Hiromasa ;
Okazaki, Ken ;
Shimoto, Takeshi ;
Higaki, Hidehiko ;
Iwamoto, Yukihide .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (08) :1799-1804
[10]   The Effect of Total Knee Arthroplasty on Knee Joint Kinematics and Kinetics During Gait [J].
Hatfield, Gillian L. ;
Hubley-Kozey, Cheryl L. ;
Wilson, Janie L. Astephen ;
Dunbar, Michael J. .
JOURNAL OF ARTHROPLASTY, 2011, 26 (02) :309-318