A novel method to ensure full recharge of a VRLA battery string

被引:0
|
作者
Suntio, T [1 ]
机构
[1] Univ Oulu, Elect Lab, FIN-90014 Oulu, Finland
来源
INTELEC(R): TWENTY-SECOND INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE | 2000年
关键词
D O I
10.1109/INTLEC.2000.884333
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
24-cells in series is most often used in Telecom applications to build a storage battery string. The individual cells are very seldom identical or they may even exhibit high inequalities in the beginning of usage. This may result in difficulties to ensure full charge. Many charge-control methods have been proposed based e.g. on battery voltage, recharge time, behavior of final charge current. Neither of these methods will ensure full charge in a reasonable time. This paper will describe a method based on the behavior of the block-voltage match error that can be effectively used as an evidence of full charge. It ran be used both in normal recharge and also in equalizing charge to ensure the recovery of full charge return. The uncertainty of full charge of every battery cells In series may also partly explain the unexpected short operational life of a VRLA battery.
引用
收藏
页码:755 / 760
页数:6
相关论文
共 50 条
  • [1] VRLA battery float, boost and recharge control using the battery string module (BSM)
    McAndrews, JM
    Jones, RH
    INTELEC 97 - 19TH INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE, PROCEEDINGS: POWER AND ENERGY SYSTEMS IN CONVERGING MARKETS, 1997, : 667 - 670
  • [2] The Novel Method for Estimating VRLA Battery State of Charge
    Tairov, Stanislav
    Stevanatto, Luiz Carlos
    2011 IEEE ELECTRONICS, ROBOTICS AND AUTOMOTIVE MECHANICS CONFERENCE (CERMA 2011), 2011, : 211 - 215
  • [3] Development of SOH monitoring system for industrial VRLA battery string
    Takahashi, K
    Watakabe, Y
    INTELEC'03: POWERING THE BROADBAND NETWORK, PROCEEDINGS, 2003, : 664 - 670
  • [4] A fault diagnosis method for VRLA battery in data center
    Li, Xinhan
    Yang, Wen
    Pang, Aiping
    Jiang, Congmei
    Zhao, Qianchuan
    Haider, Syed Naeem
    ENERGY REPORTS, 2022, 8 : 14220 - 14235
  • [5] Deterioration measuring method of VRLA battery used in UPS systems
    Takasaki, T
    Takano, K
    Ichimura, M
    INTELEC - EIGHTEENTH INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE, 1996, : 799 - 804
  • [6] A Novel Remote VRLA Battery Capacity Check Scheme for Transformer Substation
    Zhang, Wuyang
    Ding, Longyao
    Li, Yuan
    Lang, Bing
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 2027 - 2033
  • [7] Application of a New Testing Method in On-line Testing for VRLA Battery
    Zhao Yuefei
    Sun Fu
    Guo Huiguang
    ISTM/2009: 8TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, 2009, : 231 - 234
  • [8] Charge Equalized Module for Serially Connected VRLA Battery String using Quasi-resonant Flyback Converter
    Karnjanapiboon, C.
    Jirasereeamornkul, K.
    Monyakul, V
    ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 4, 2010, : 415 - +
  • [9] Corrosion resistant positive grids, novel separators, and negative plate additives for increased VRLA battery life
    Prengaman, RD
    Siegmund, A
    SIXTEENTH ANNUAL BATTERY CONFERENCE ON APPLICATIONS AND ADVANCES, 2001, : 201 - 205
  • [10] VRLA battery fault prediction for data center based on random forest model and feature enhancement method
    Li, Xinhan
    Pang, Aiping
    Yang, Wen
    Zhao, Qianchuan
    JOURNAL OF ENERGY STORAGE, 2023, 72