The effects of cementless femoral stem shape and proximal surface texture on 'fit-and-fill' characteristics and on bone remodeling

被引:63
作者
Laine, HJ [1 ]
Poulakka, TJS [1 ]
Moilanen, T [1 ]
Pajamäki, KJ [1 ]
Wirta, J [1 ]
Lehto, MUK [1 ]
机构
[1] Univ Tampere, Sch Med, Dept Surg, Div Orthopaed, Tampere 33521, Finland
关键词
D O I
10.1007/s002640000150
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We measured the post-operative radiological "fit and fill" of two different femoral stem designs, one with a straight proximally porous-coated (Bi-Metric, n=50) and the other with a proximally anatomic, hydroxyapatite-coated and distally over-reamed stem (ABG, n=26). A comparison was then made between the clinical and radiological 5-year follow-up data of these two series and also of the bone remodeling changes around the stems. The observed differences in "fit and fill" parameters in the metaphyseal region were minute. However, in the diaphyseal bone the straight stem had substantially mon cortical contact. The clinical results were excellent for both groups. Subsidence (>2 mm) was mon frequent with the anatomical ABG stems, although the ABG stems had better bone ingrowth in the lower metaphyseal area. The present results indicate that the anatomical design may improve the fit and fill of a femoral stem in the metaphysis. On the other hand, a looser fill of the diaphyseal bone made the stems of this type more susceptible to subsidence. The straight stem with tight diaphyseal fit showed excellent stability, but the good bone ingrowth and remodeling around the distal part of the stem indicates stress transfer through this region and increased stress shielding of the proximal metaphyseal femur.
引用
收藏
页码:184 / 190
页数:7
相关论文
共 53 条
[31]   Integral porous femoral stem - 5- to 8-year follow-up study [J].
Mauerhan, DR ;
Mesa, J ;
Gregory, AM ;
Mokris, JG .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :250-255
[32]  
MORREY BF, 1989, CLIN ORTHOP RELAT R, P169
[33]   Early radiographic results comparing cemented and cementless total hip arthroplasty [J].
Mulliken, BD ;
Nayak, N ;
Bourne, RB ;
Rorabeck, CH ;
Bullas, R .
JOURNAL OF ARTHROPLASTY, 1996, 11 (01) :24-33
[34]   Effect of a stemless femoral implant for total hip arthroplasty on the bone mineral density of the proximal femur - A prospective longitudinal study [J].
Munting, E ;
Smitz, P ;
VanSante, N ;
deDeuxchaisnes, CN ;
Vincent, A ;
Devogelaer, JP .
JOURNAL OF ARTHROPLASTY, 1997, 12 (04) :373-379
[35]  
Noble P.C., 1988, CLIN ORTHOP RELAT R, V235, P148
[36]   A COLLARLESS COBALT-CHROME FEMORAL COMPONENT IN UNCEMENTED TOTAL HIP-ARTHROPLASTY [J].
PELLEGRINI, VD ;
HUGHES, SS ;
EVARTS, CM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (06) :814-821
[37]  
PILLIAR RM, 1986, CLIN ORTHOP RELAT R, P108
[38]   Clinical and radiographic outcomes of total hip arthroplasty with insertion of an anatomically designed femoral component without cement for the treatment of primary osteoarthritis - A study with a minimum of six years of follow-up [J].
Ragab, AA ;
Kraay, MJ ;
Goldberg, VM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (02) :210-218
[39]  
Robertsen K, 1996, ORTHOPEDICS, V19, P673
[40]   DESIGN OF CUSTOM HIP STEM PROSTHESES USING 3-DIMENSIONAL CT MODELING [J].
ROBERTSON, DD ;
WALKER, PS ;
GRANHOLM, JW ;
NELSON, PC ;
WEISS, PJ ;
FISHMAN, EK ;
MAGID, D .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) :804-809