The effects of cementless femoral stem shape and proximal surface texture on 'fit-and-fill' characteristics and on bone remodeling

被引:64
作者
Laine, HJ [1 ]
Poulakka, TJS [1 ]
Moilanen, T [1 ]
Pajamäki, KJ [1 ]
Wirta, J [1 ]
Lehto, MUK [1 ]
机构
[1] Univ Tampere, Sch Med, Dept Surg, Div Orthopaed, Tampere 33521, Finland
关键词
D O I
10.1007/s002640000150
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We measured the post-operative radiological "fit and fill" of two different femoral stem designs, one with a straight proximally porous-coated (Bi-Metric, n=50) and the other with a proximally anatomic, hydroxyapatite-coated and distally over-reamed stem (ABG, n=26). A comparison was then made between the clinical and radiological 5-year follow-up data of these two series and also of the bone remodeling changes around the stems. The observed differences in "fit and fill" parameters in the metaphyseal region were minute. However, in the diaphyseal bone the straight stem had substantially mon cortical contact. The clinical results were excellent for both groups. Subsidence (>2 mm) was mon frequent with the anatomical ABG stems, although the ABG stems had better bone ingrowth in the lower metaphyseal area. The present results indicate that the anatomical design may improve the fit and fill of a femoral stem in the metaphysis. On the other hand, a looser fill of the diaphyseal bone made the stems of this type more susceptible to subsidence. The straight stem with tight diaphyseal fit showed excellent stability, but the good bone ingrowth and remodeling around the distal part of the stem indicates stress transfer through this region and increased stress shielding of the proximal metaphyseal femur.
引用
收藏
页码:184 / 190
页数:7
相关论文
共 53 条
[1]  
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[2]  
Araujo CG, 1998, J ARTHROPLASTY, V13, P660
[3]   MICROMOTION OF CEMENTED AND UNCEMENTED FEMORAL COMPONENTS [J].
BURKE, DW ;
OCONNOR, DO ;
ZALENSKI, EB ;
JASTY, M ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (01) :33-37
[4]   A femoral component inserted without cement in total hip arthroplasty - A study of the Tri-Lock component with an average ten-year duration of follow-up [J].
Burt, CF ;
Garvin, KL ;
Otterberg, ET ;
Jardon, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (07) :952-960
[5]   THE EFFECT OF FEMORAL STEM GEOMETRY ON INTERFACE MOTION IN UNCEMENTED POROUS-COATED TOTAL HIP PROSTHESES - COMPARISON OF STRAIGHT-STEM AND CURVED-STEM DESIGNS [J].
CALLAGHAN, JJ ;
FULGHUM, CS ;
GLISSON, RR ;
STRANNE, SK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (06) :839-848
[6]   EFFECT OF MOVEMENT ON BONDING OF POROUS METAL TO BONE [J].
CAMERON, HU ;
PILLIAR, RM ;
MACNAB, I .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1973, 7 (04) :301-311
[7]   Radiological and survival comparison of four methods of fixation of a proximal femoral stem [J].
Donnelly, WJ ;
Kobayashi, A ;
Freeman, MAR ;
Chin, TW ;
Yeo, H ;
West, M ;
Scott, G .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (03) :351-360
[8]   Long-term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty [J].
Engh, CA ;
Culpepper, WJ ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (02) :177-184
[9]  
Engh CA., 1990, CLIN ORTHOP RELAT R, V257, P107
[10]  
ENGH CA, 1990, CLIN ORTHOP RELAT R, V261, P63