Effectiveness of neonatal pulse oximetry screening for detection of critical congenital heart disease in daily clinical routine-results from a prospective multicenter study

被引:169
|
作者
Riede, Frank Thomas [1 ]
Woerner, Cornelia [1 ]
Daehnert, Ingo [1 ]
Moeckel, Andreas [2 ]
Kostelka, Martin [1 ]
Schneider, Peter [1 ]
机构
[1] Univ Leipzig, Ctr Heart, D-04289 Leipzig, Germany
[2] Helios Klinikum Borna, Dept Pediat, D-04552 Borna, Germany
关键词
Prenatal ultrasound; Physical examination; Pulse oximetry screening; Newborn; Critical congenital heart disease; ASYMPTOMATIC NEWBORNS; OXYGEN-SATURATION; DEFECTS; DIAGNOSIS; MALFORMATIONS; DISCHARGE; FAILURE; INFANTS; AGE;
D O I
10.1007/s00431-010-1160-4
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Pulse oximetry screening (POS) has been proposed as an effective, noninvasive, inexpensive tool allowing earlier diagnosis of critical congenital heart disease (cCHD). Our aim was to test the hypothesis that POS can reduce the diagnostic gap in cCHD in daily clinical routine in the setting of tertiary, secondary and primary care centres. We conducted a prospective multicenter trial in Saxony, Germany. POS was performed in healthy term and post-term newborns at the age of 24-72 h. If an oxygen saturation (SpO(2)) of a parts per thousand currency sign95% was measured on lower extremities and confirmed after 1 h, complete clinical examination and echocardiography were performed. POS was defined as false-negative when a diagnosis of cCHD was made after POS in the participating hospitals/at our centre. From July 2006-June 2008, 42,240 newborns from 34 institutions have been included. Seventy-two children were excluded due to prenatal diagnosis (n = 54) or clinical signs of cCHD (n = 18) before POS. Seven hundred ninety-five newborns did not receive POS, mainly due to early discharge after birth (n = 727; 91%). In 41,445 newborns, POS was performed. POS was true positive in 14, false positive in 40, true negative in 41,384 and false negative in four children (three had been excluded for violation of study protocol). Sensitivity, specificity, positive and negative predictive value were 77.78%, 99.90%, 25.93% and 99.99%, respectively. With POS as an adjunct to prenatal diagnosis, physical examination and clinical observation, the percentage of newborns with late diagnosis of cCHD was 4.4%. POS can substantially reduce the postnatal diagnostic gap in cCHD, and false-positive results leading to unnecessary examinations of healthy newborns are rare. POS should be implemented in routine postnatal care.
引用
收藏
页码:975 / 981
页数:7
相关论文
共 50 条
  • [41] Combining Pulse Oximetry and Clinical Examination in Screening for Congenital Heart Disease
    A.F. Bakr
    H.S. Habib
    Pediatric Cardiology, 2005, 26 : 832 - 835
  • [42] Combining pulse oximetry and clinical examination in screening for congenital heart disease
    Bakr, AF
    Habib, HS
    PEDIATRIC CARDIOLOGY, 2005, 26 (06) : 832 - 835
  • [43] Pulse oximetry screening to detect cyanotic congenital heart disease in sick neonates in a neonatal intensive care unit
    Mathur, N. B.
    Gupta, A.
    Kurien, S.
    INDIAN PEDIATRICS, 2015, 52 (09) : 769 - 772
  • [44] Misinterpretation of Negative Pulse Oximetry Screening as Absence of Critical Congenital Heart Disease
    Krishna Dummula
    Vishal Pandey
    Pediatric Cardiology, 2012, 33 : 1477 - 1477
  • [45] Misinterpretation of Negative Pulse Oximetry Screening as Absence of Critical Congenital Heart Disease
    Dummula, Krishna
    Pandey, Vishal
    PEDIATRIC CARDIOLOGY, 2012, 33 (08) : 1477 - 1477
  • [46] Implementation of a Critical Congenital Heart Disease Pulse Oximetry Screening Program for Newborns
    Salazar, Mary Ann
    JOGNN-JOURNAL OF OBSTETRIC GYNECOLOGIC AND NEONATAL NURSING, 2013, 42 : S40 - S41
  • [47] Pulse Oximetry Screening for Critical Congenital Heart Disease: Bringing Evidence Into Practice
    Amsbaugh, Sarah
    Scott, Shannon D.
    Foss, Karen
    JOURNAL OF PEDIATRIC NURSING-NURSING CARE OF CHILDREN & FAMILIES, 2015, 30 (04): : 591 - 597
  • [48] Audit of pulse oximetry screening for critical congenital heart disease (CCHD) in newborns
    Lightfoot, Marnie
    Hough, Philip
    Hudak, Alan
    Gordon, Michelle
    Barker, Sarah
    Meeder, Robert
    Colpitts, Melanie
    Roberts, Gwendolyn
    Smith, William Gary
    PAEDIATRICS & CHILD HEALTH, 2017, 22 (06) : 305 - 306
  • [49] Current Postlaunch Implementation of State Mandates of Newborn Screening for Critical Congenital Heart Disease by Pulse Oximetry in US States and Hospitals
    Sakai-Bizmark, Rie
    Chang, Ruey-Kang R.
    Martin, Gerard R.
    Hom, Lisa A.
    Marr, Emily H.
    Ko, Jamie
    Goff, Donna A.
    Mena, Laurie A.
    von Kohler, Connie
    Bedel, Lauren E. M.
    Murillo, Mary
    Estevez, Dennys
    Hays, Ron D.
    AMERICAN JOURNAL OF PERINATOLOGY, 2024, 41 : e550 - e562
  • [50] Cost-effectiveness analysis of newborn pulse oximetry screening to detect critical congenital heart disease in Colombia
    Dario Londoño Trujillo
    Nestor Fernando Sandoval Reyes
    Alejandra Taborda Restrepo
    Cindy Lorena Chamorro Velasquez
    Maria Teresa Dominguez Torres
    Sandra Vanessa Romero Ducuara
    Gloria Amparo Troncoso Moreno
    Hernan Camilo Aranguren Bello
    Alejandra Fonseca Cuevas
    Pablo Andres Bermudez Hernandez
    Pablo Sandoval Trujillo
    Rodolfo Jose Dennis
    Cost Effectiveness and Resource Allocation, 17