The significance of repeat testing in Turkish blood donors screened with HBV, HCV and HIV immunoassays and the importance of S/CO ratios in the interpretation of HCV/HIV screening test results and as a determinant for further confirmatory testing

被引:20
作者
Acar, Ali [1 ]
Kemahli, Sabri [2 ]
Altunay, Husnu [3 ]
Kosan, Erdogan [3 ]
Oncul, Oral [1 ]
Gorenek, Levent [1 ]
Cavuslu, Saban [1 ]
机构
[1] Haydarpasa Training Hosp, Gulhane Mil Med Acad, Dept Infect Dis & Clin Microbiol, TR-34668 Istanbul, Turkey
[2] Ankara Univ, Fac Med, Dept Paediat Ped Haematol, TR-06100 Ankara, Turkey
[3] Capa Red Crescent Ctr, Istanbul, Turkey
关键词
blood donors; HBV; HCV; HIV; screening tests; REACTIVITY; ALGORITHMS; ASSAYS;
D O I
10.1111/j.1365-3148.2009.00987.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to investigate the intra-assay correlations amongst initial reactive and repeat screening results used in enzyme immunoassays (EIAs) for hepatitis B virus (HBV), hepatitis C virus (HCV) and HIV in blood donors. This study evaluated the value of using the power of the signal to cut-off (S/CO) ratio index for confirming anti-HCV/HIV reactive screening results, thereby touching upon the utility of S/CO indices in determining whether further confirmatory testing was necessary. Screening test results of the 72 695 blood donors were evaluated over a 1-year period. Correlation analysis among each initial test and retests was done by Pearson r test. Appropriate S/CO values to determine the need of the confirmation testing was investigated by ROC analyses. EIA intra-assay correlations were of statistical significance and were determined as follows: 0 center dot 948 for anti-HCV, 0 center dot 827 for anti-HIV and 0 center dot 948 for HBsAg. The threshold S/CO ratio values which predicted more than 95% of the confirmation test result were 3 center dot 8 for HCV and 5 center dot 6 for HIV. We were able to demonstrate a strong level of intra-assay correlation amongst EIAs, thereby eliminating the need for repetition of the screening test. Hence, we suggest that repeat screening should only be limited to HBV and HIV tests with low EIA S/CO ratios. Thus, using the power of the S/CO ratio in determining the need for HCV confirmation testing can be a cost-effective measure, especially if the S/CO value is >= 3 center dot 8.
引用
收藏
页码:152 / 159
页数:8
相关论文
共 13 条
[1]  
[Anonymous], 1991, MMWR Recomm Rep, V40, P1
[2]   Cost-effective analysis of different algorithms for the diagnosis of hepatitis C virus infection [J].
Barreto, A. M. E. C. ;
Takei, K. ;
Sabino, E. C. ;
Bellesa, M. A. O. ;
Salles, N. A. ;
Barreto, C. C. ;
Nishiya, A. S. ;
Chamone, D. F. .
BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2008, 41 (02) :126-134
[3]  
CDC, 2001, Morbidity and Mortality Weekly Report, V50, P1
[4]   Sensitivity and specificity of third-generation hepatitis C virus antibody detection assays: an analysis of the literature [J].
Colin, C ;
Lanoir, D ;
Touzet, S ;
Meyaud-Kraemer, L ;
Bailly, F ;
Trepo, C .
JOURNAL OF VIRAL HEPATITIS, 2001, 8 (02) :87-95
[5]   Hepatitis C antibody intraassay correlation:: is retest in duplicate necessary? [J].
Contreras, Ana M. ;
Tinoco, Erendi ;
Celis, Alfredo ;
Novelo, Babara ;
Romero, M. V. Patricia ;
Carrada, Etelvina ;
Jimenez-Mendez, Ricardo .
TRANSFUSION, 2007, 47 (09) :1686-1690
[6]   Results of HCV screening of volunteer blood donors with a chemiluminescent immunoassay and a second- or third-generation EIA: overlap of false-positive reactivity and its impact on donor management [J].
Kiely, P ;
Wilson, D .
TRANSFUSION, 2000, 40 (05) :580-584
[7]   Analysis of voluntary blood donors with biologic false reactivity on chemiluminescent immunoassays and implications for donor management [J].
Kiely, P ;
Stewart, Y ;
Castro, L .
TRANSFUSION, 2003, 43 (05) :584-590
[8]   Integration of nucleic acid amplification test results into hepatitis C virus supplemental serologic testing algorithms: implications for donor counseling and revision of existing algorithms [J].
Kleinman, SH ;
Stramer, SL ;
Brodsky, JP ;
Caglioti, S ;
Busch, MP .
TRANSFUSION, 2006, 46 (05) :695-702
[9]   Performance of three automated fourth-generation combined HIV antigen/antibody assays in large-scale screening of blood donors and clinical samples [J].
Malm, K. ;
von Sydow, M. ;
Andersson, S. .
TRANSFUSION MEDICINE, 2009, 19 (02) :78-88
[10]  
Mazurek G.H., 2003, MMWR RECOMM REP, V52, P15