The relationship between intracranial pressure and obesity: an ultrasonographic evaluation of the optic nerve

被引:16
作者
Dip, Fernando [1 ]
Nguyen, David [1 ]
Sasson, Morris [1 ]
Lo Menzo, Emanuele [1 ]
Szomstein, Samuel [1 ]
Rosenthal, Raul [1 ]
机构
[1] Cleveland Clin Florida, Sect Minimally Invas Surg, Dept Gen Surg, Bariatr & Metab Inst, 2950 Cleveland Clin Blvd, Weston, FL 33331 USA
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2016年 / 30卷 / 06期
关键词
Abdominal; Bariatric; Obesity; INCREASED INTRAABDOMINAL PRESSURE; SAGITTAL ABDOMINAL DIAMETER; SHEATH DIAMETER; HYPERTENSION;
D O I
10.1007/s00464-015-4458-5
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Measurements of optic nerve sheath diameter (ONSD) with noninvasive ocular ultrasonography have been shown to be accurate in determining increased intracranial pressure. Obesity is associated with chronic increases in intraabdominal pressure that could consequently result in intracranial hypertension. By utilizing ONSD ultrasonographic measurements, we compare the difference that may exist between obese and non-obese patients. Study Design We prospectively collected data from patients who underwent laparoscopic procedures in the supine position between July 2013 and March 2014. Ophthalmic pathology was not present in any patient. Ultrasonographic measurement of the ONSD was obtained sagittally with a 12-MHz transducer 3 mm from its origin. The measurements were taken at 0, 15, and 30 min, and at the end of surgery. Results There were 62 subjects, 28 females (45.2 %) and 34 males (54.8 %), with a mean age of 44.22 +/- 10.44 years (range 23-66). Forty-eight percent of patients were non-obese, and 52 % of patients were obese. The mean body mass index was 30.70 +/- 7.61 kg/m(2) (range 20.0-59.5). The mean ONSD of non-obese and obese patients was 4.7 and 5.5 mm at baseline (p = 0.01), 5.4 and 6.2 mm at 15 min (p = 0.01), 5.8 and 6.6 mm at 30 min (p = 0.01), and 5.1 and 5.7 mm after deflation of pneumoperitoneum (p = 0.03), respectively. Conclusions Utilizing a noninvasive method to measure the ONSD, a chronic increase in intracranial pressure in obese patients was demonstrated. The increase in the ONSD during laparoscopic procedures reflects a temporary increase in the intracranial pressure from baseline.
引用
收藏
页码:2321 / 2325
页数:5
相关论文
共 26 条
[1]   Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging [J].
Baeuerle, Jochen ;
Schuchardt, Florian ;
Schroeder, Laure ;
Egger, Karl ;
Weigel, Matthias ;
Harloff, Andreas .
BMC NEUROLOGY, 2013, 13
[2]  
Ballantyne S A, 2002, Eur J Ultrasound, V15, P145, DOI 10.1016/S0929-8266(02)00036-8
[3]   Association of Benign Intracranial Hypertension and Spontaneous Encephalocele With Cerebrospinal Fluid Leak [J].
Brainard, Laura ;
Chen, Douglas A. ;
Aziz, Khaled M. ;
Hillman, Todd A. .
OTOLOGY & NEUROTOLOGY, 2012, 33 (09) :1621-1624
[4]   Optic nerve sheath diameter and lumbar puncture opening pressure in nontrauma patients suspected of elevated intracranial pressure [J].
Caffery, Terrell S. ;
Perret, J. Nelson ;
Musso, Mandi W. ;
Jones, Glenn N. .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2014, 32 (12) :1513-1515
[5]   CARDIOVASCULAR, PULMONARY, AND RENAL EFFECTS OF MASSIVELY INCREASED INTRA-ABDOMINAL PRESSURE IN CRITICALLY ILL PATIENTS [J].
CULLEN, DJ ;
COYLE, JP ;
TEPLICK, R ;
LONG, MC .
CRITICAL CARE MEDICINE, 1989, 17 (02) :118-121
[6]   Non-Invasive Intracranial Pressure Methods during Pneumoperitoneum in an Animal Model [J].
Dip, Fernando ;
Nguyen, David ;
Lomenzo, Emanuele ;
Szomstein, Samuel ;
Szetter, Eugenia ;
Rosenthal, Raul J. .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2014, 219 (03) :S62-S63
[7]   Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure [J].
Frumin, Erica ;
Schlang, Joelle ;
Wiechmann, Warren ;
Hata, Stacy ;
Rosen, Sasha ;
Anderson, Craig ;
Pare, Laura ;
Rosen, Mark ;
Fox, John Christian .
WESTERN JOURNAL OF EMERGENCY MEDICINE, 2014, 15 (02) :217-220
[8]   Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients [J].
Geeraerts, Thomas ;
Merceron, Sybille ;
Benhamou, Dan ;
Vigue, Bernard ;
Duranteau, Jacques .
INTENSIVE CARE MEDICINE, 2008, 34 (11) :2062-2067
[9]   Obesity [J].
Haslam, DW ;
James, WPT .
LANCET, 2005, 366 (9492) :1197-1209
[10]   Increase in Intracranial Pressure During Carbon Dioxide Pneumoperitoneum with Steep Trendelenburg Positioning Proven by Ultrasonographic Measurement of Optic Nerve Sheath Diameter [J].
Kim, Min-Soo ;
Bai, Sun-Joon ;
Lee, Jeong-Rim ;
Choi, Young Deuk ;
Kim, Yoon Jae ;
Choi, Seung Ho .
JOURNAL OF ENDOUROLOGY, 2014, 28 (07) :801-806