In-stent-stenosis of a bare-metal stent 11 years after its implantation

被引:0
作者
Skarlos, A. C. [1 ]
Zahn, R. [1 ]
Zeymer, U. [1 ]
机构
[1] Herzzentrum Ludwigshafen, Med Klin B, Klinikum Stadt Ludwigshafen, D-67063 Ludwigshafen, Germany
关键词
very late in-stent-stenosis; bare-metal stent; percutaneous coronary intervention; ballon-angioplasty; CORONARY STENTS; MODERN-ERA; RESTENOSIS; THROMBOSIS; PATHOPHYSIOLOGY; TRIALS;
D O I
10.1055/s-0030-1253700
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
History and admission findings: A 52-year-old man was admitted to our hospital with unstable angina pectoris. A balloon angioplasty of his left anterior descending artery had been performed 12 years ago and two bare-metal stents had been implanted two months later for an early restenosis. Diagnostic procedures: Bicycle ergometry was stopped because the patient experienced angina pectoris and the electrocardiogram showed ST-segment depression in leads V4-V6. Treatment and outcome: A coronary angiography was performed and a single-vessel disease with a significant in-stent stenosis of the proximal left anterior descending artery was diagnosed. Another successful percutaneous coronary intervention was performed with implantation of a drug-eluting stent. The further hospital course was uneventful. Conclusion: Even after more than 11 years an in-stent stenosis of a bare-metal stent can occur without progression of coronary artery disease in the other coronary arteries.
引用
收藏
页码:1067 / 1070
页数:4
相关论文
共 50 条
  • [41] A case report of very late thrombosis of coronary bare-metal stent 10 years after stenting
    Katayama, Toshiro
    Yamamoto, Tadashi
    Iwasaki, Yoshihiro
    INTERNATIONAL HEART JOURNAL, 2007, 48 (04) : 547 - 552
  • [42] Efficacy and safety of drug-eluting stent implantation for the treatment of in-stent restenosis occurring within bare-metal stent and drug-eluting stent
    Ge, Heng
    Zhang, Qing
    Zhou, Wei
    He, Qing
    Han, Zhi-hua
    He, Ben
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B, 2010, 11 (08): : 553 - 560
  • [43] Incidence and very long- term outcomes of stent thrombosis after bare-metal or drug-eluting stent implantation: a retrospective analysis
    Pullara, A.
    Longo, G.
    Gonella, A.
    D'Ascenzo, F.
    Zoccai, G. Biondi
    Moretti, C.
    Sciuto, F.
    Omede, P. L.
    Bollati, M.
    Gaita, F.
    Sheiban, I.
    MINERVA CARDIOANGIOLOGICA, 2013, 61 (01): : 1 - 9
  • [44] Stent thrombosis following bare-metal stent implantation:: success of emergency percutaneous coronary intervention and predictors of adverse outcome
    Wenaweser, P
    Rey, C
    Eberli, FR
    Togni, M
    Tüller, D
    Locher, S
    Remondino, A
    Seiler, C
    Hess, OM
    Meier, B
    Windecker, S
    EUROPEAN HEART JOURNAL, 2005, 26 (12) : 1180 - 1187
  • [45] Eosinophil cationic protein and clinical outcome after bare metal stent implantation
    Niccoli, Giampaolo
    Sgueglia, Gregory A.
    Conte, Micaela
    Cosentino, Nicola
    Minelli, Silvia
    Belloni, Flavia
    Trani, Carlo
    Sabato, Vito
    Burzotta, Francesco
    Porto, Italo
    Leone, Antonio Maria
    Schiavino, Domenico
    Crea, Filippo
    ATHEROSCLEROSIS, 2011, 215 (01) : 166 - 169
  • [46] Acute myocardial infarction caused by rupture of minimal intrastent intimal hyperplasia after implantation of bare-metal stent
    Kang, Woong Chol
    Han, Seung Hwan
    Ahn, Tae Hoon
    Shin, Eak Kyun
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 120 (02) : E37 - E40
  • [47] Multimodality Visualization With 3-Dimensional Reconstruction of Neointimal Plaque Rupture After Bare-Metal Stent Implantation
    Sudo, Mitsumasa
    Hiro, Takafumi
    Takayama, Tadateru
    Iida, Korehito
    Nishida, Toshihiko
    Kawano, Taro
    Kanai, Takashi
    Higuchi, Yoshiharu
    Hirayama, Atsushi
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (10) : E163 - E165
  • [48] Bare metal stent implantation for in-stent restenosis with a drug-eluting stent
    Matsuoka, Hiroshi
    Kawakami, Hideo
    Ohshita, Akira
    Kohno, Tamami
    Shigemi, Susumu
    Okayama, Hideki
    Higaki, Jitsuo
    JOURNAL OF CARDIOLOGY, 2010, 55 (01) : 135 - 138
  • [49] Very Long-Term (15 to 20 Years) Clinical and Angiographic Outcome After Coronary Bare Metal Stent Implantation
    Yamaji, Kyohei
    Kimura, Takeshi
    Morimoto, Takeshi
    Nakagawa, Yoshihisa
    Inoue, Katsumi
    Soga, Yoshimitsu
    Arita, Takeshi
    Shirai, Shinichi
    Ando, Kenji
    Kondo, Katsuhiro
    Sakai, Koyu
    Goya, Masahiko
    Iwabuchi, Masashi
    Yokoi, Hiroyoshi
    Nosaka, Hideyuki
    Nobuyoshi, Masakiyo
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (05) : 468 - 475
  • [50] Role of Pioglitazone in the Prevention of Restenosis and Need for Revascularization After Bare-Metal Stent Implantation A Meta-Analysis
    Patel, Dhavalkumar
    Walitt, Brian
    Lindsay, Joseph
    Wilensky, Robert L.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (03) : 353 - 360