共 50 条
In-stent-stenosis of a bare-metal stent 11 years after its implantation
被引:0
作者:
Skarlos, A. C.
[1
]
Zahn, R.
[1
]
Zeymer, U.
[1
]
机构:
[1] Herzzentrum Ludwigshafen, Med Klin B, Klinikum Stadt Ludwigshafen, D-67063 Ludwigshafen, Germany
关键词:
very late in-stent-stenosis;
bare-metal stent;
percutaneous coronary intervention;
ballon-angioplasty;
CORONARY STENTS;
MODERN-ERA;
RESTENOSIS;
THROMBOSIS;
PATHOPHYSIOLOGY;
TRIALS;
D O I:
10.1055/s-0030-1253700
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
History and admission findings: A 52-year-old man was admitted to our hospital with unstable angina pectoris. A balloon angioplasty of his left anterior descending artery had been performed 12 years ago and two bare-metal stents had been implanted two months later for an early restenosis. Diagnostic procedures: Bicycle ergometry was stopped because the patient experienced angina pectoris and the electrocardiogram showed ST-segment depression in leads V4-V6. Treatment and outcome: A coronary angiography was performed and a single-vessel disease with a significant in-stent stenosis of the proximal left anterior descending artery was diagnosed. Another successful percutaneous coronary intervention was performed with implantation of a drug-eluting stent. The further hospital course was uneventful. Conclusion: Even after more than 11 years an in-stent stenosis of a bare-metal stent can occur without progression of coronary artery disease in the other coronary arteries.
引用
收藏
页码:1067 / 1070
页数:4
相关论文