In-stent-stenosis of a bare-metal stent 11 years after its implantation

被引:0
作者
Skarlos, A. C. [1 ]
Zahn, R. [1 ]
Zeymer, U. [1 ]
机构
[1] Herzzentrum Ludwigshafen, Med Klin B, Klinikum Stadt Ludwigshafen, D-67063 Ludwigshafen, Germany
关键词
very late in-stent-stenosis; bare-metal stent; percutaneous coronary intervention; ballon-angioplasty; CORONARY STENTS; MODERN-ERA; RESTENOSIS; THROMBOSIS; PATHOPHYSIOLOGY; TRIALS;
D O I
10.1055/s-0030-1253700
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
History and admission findings: A 52-year-old man was admitted to our hospital with unstable angina pectoris. A balloon angioplasty of his left anterior descending artery had been performed 12 years ago and two bare-metal stents had been implanted two months later for an early restenosis. Diagnostic procedures: Bicycle ergometry was stopped because the patient experienced angina pectoris and the electrocardiogram showed ST-segment depression in leads V4-V6. Treatment and outcome: A coronary angiography was performed and a single-vessel disease with a significant in-stent stenosis of the proximal left anterior descending artery was diagnosed. Another successful percutaneous coronary intervention was performed with implantation of a drug-eluting stent. The further hospital course was uneventful. Conclusion: Even after more than 11 years an in-stent stenosis of a bare-metal stent can occur without progression of coronary artery disease in the other coronary arteries.
引用
收藏
页码:1067 / 1070
页数:4
相关论文
共 50 条
  • [1] Very late stent thrombosis in a bare-metal stent, 9 years after implantation
    Almasswary, Adel A.
    SAUDI MEDICAL JOURNAL, 2009, 30 (06) : 847 - 850
  • [2] Bare-Metal Stent Thrombosis after Noncardiac Surgery Greater than 10 Years after Stent Implantation
    Willis, Nicholas
    Sachdeva, Rajesh
    Uretsky, Barry F.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (02) : 234 - 236
  • [3] Takayasu Arteritis: Stenosis after Bare-Metal and Drug-Eluting Stent Implantation
    Soeiro, Alexandre de Matos
    Pinto, Ana Luiza
    Henares, Bruna Bernardes
    Ribeiro, Henrique Barbosa
    Lima, Felipe Gallego
    Serrano, Carlos Vicente, Jr.
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2013, 100 (01) : E8 - E11
  • [4] Impact of stent diameter and length on in-stent restenosis after bare metal stent implantation
    Nita, Daniel
    Gurzun, Magdalena
    Chiriac, Liviu
    Cirstea, Adela Ileana
    Parepa, Raluca Irinel
    Barbilian, Adrian Gheorghe
    ROMANIAN BIOTECHNOLOGICAL LETTERS, 2017, 22 (02): : 12347 - 12351
  • [5] Calcified plaque rupture and very late stent thrombosis after bare-metal stent implantation
    Yumoto K.
    Anzai T.
    Aoki H.
    Inoue A.
    Funada S.
    Nishiyama H.
    Tanaka S.
    Kowase S.
    Shirai Y.
    Kurosaki K.
    Nogami A.
    Daida H.
    Kato K.
    Cardiovascular Intervention and Therapeutics, 2011, 26 (3) : 252 - 259
  • [6] Background incidence of late malapposition after bare-metal stent implantation
    Shah, VM
    Mintz, G
    Apple, S
    Weissman, NJ
    CIRCULATION, 2002, 106 (14) : 1753 - 1755
  • [7] Very late bare-metal stent thrombosis 10 years after the implantation: A case report
    Mboup, M. C.
    Moquet, B.
    Zabalawi, A.
    Delaunay, R.
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 2013, 62 (06): : 435 - 437
  • [8] Bare metal stent thrombosis 13 years after implantation
    Sarkees, Michael L.
    Bavry, Anthony A.
    Galla, John M.
    Bhatt, Deepak L.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2009, 10 (01) : 58 - 59
  • [9] The Myths of the Bare-Metal Stent
    Kereiakes, Dean J.
    JAMA CARDIOLOGY, 2018, 3 (11) : 1039 - 1040
  • [10] Antibody-mediated PCSK9 neutralization worsens outcome after bare-metal stent implantation in mice
    Puspitasari, Yustina M.
    Ministrini, Stefano
    Liberale, Luca
    Vukolic, Ana
    Baumann-Zumstein, Philine
    Holy, Erik W.
    Montecucco, Fabrizio
    Luescher, Thomas F.
    Camici, Giovanni G.
    VASCULAR PHARMACOLOGY, 2023, 153