dental implants; frequency analysis; implant-supported overdenture; prosthetic complication; RETAINED MANDIBULAR OVERDENTURES; CONTROLLED CLINICAL-TRIAL; ASTRA TECH IMPLANTS; MAXILLARY OVERDENTURES; PATIENT SATISFACTION; PROSTHODONTIC MAINTENANCE; ENDOSSEOUS IMPLANTS; BRANEMARK IMPLANTS; TREATMENT OUTCOMES; BAR ATTACHMENTS;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate prosthetic maintenance requirements for implant-retained/supported overdentures via a review of the literature. Materials and Methods: Using the combined search terms "implant and overdenture," "implant-supported overdenture," "implant-retained overdenture," and "implant-anchored overdenture," along with specific inclusion and exclusion criteria, eligible articles between 1997 and 2008 (up to April 1) were retrieved from PubMed, EMBASE, OVID, the Cochrane Library databases, and seven journals by hand-searching. The initial search yielded 3,120 titles, and 287 articles were assigned to full-text analysis. Upon classification of the prosthetic complications with regard to the jaws treated and the attachment systems used, within- and between-group comparative frequency analyses were undertaken with the Kruskal-Wallis test or the Mann-Whitney U test at P < .05. Results: A total of 49 articles were included. Within- and between-group evaluations with regard to jaw treated as well as the attachment systems used showed that the frequency of complications did not change over time (P > .05). The differences detected were more matrix replacements after 5 years in the maxilla and mandible and more matrix replacements and patrix fractures after the first year in the mandible (P < .05). Among the attachment systems, a dislodged, worn, or loose matrix or its respective housing was more common in the ball-attachment group after the first year (P < .05). Prosthetic complications for all types of attachments were comparable (P > .05), except for the differences in peri-implant or interabutment mucosal enlargement rates after 1 year. Conclusions: Prosthetic maintenance requirements for overdentures on both jaws seem to be comparable. The impact of attachment system on the prosthetic outcome is negligible. INT J ORAL MAXILLOFAC IMPLANTS 2010; 25: 163-180
引用
收藏
页码:163 / 180
页数:18
相关论文
共 50 条
  • [41] Investigation of the implant-supported overdentures in completely edentulous mandibles
    Pan, Yu-Hwa
    Chen, Kuan-Wei
    Lin, Tai-Min
    Chang, Yang-Ming
    JOURNAL OF DENTAL SCIENCES, 2015, 10 (04) : 444 - 449
  • [42] A retrospective evaluation of treatments with implant-supported maxillary overdentures
    Widbom, C
    Söderfeldt, B
    Kronström, M
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2005, 7 (03) : 166 - 172
  • [43] Treatment outcomes with implant-supported overdentures: Clinical considerations
    Mericske-Stern, R
    JOURNAL OF PROSTHETIC DENTISTRY, 1998, 79 (01): : 66 - 73
  • [44] Prosthetic outcome of cement-retained implant-supported fixed dental restorations: a systematic review
    Chaar, M. S.
    Att, W.
    Strub, J. R.
    JOURNAL OF ORAL REHABILITATION, 2011, 38 (09) : 697 - 711
  • [45] Prosthodontic Maintenance of Maxillary Implant Overdentures: A Systematic Literature Review
    Osman, Reham B.
    Payne, Alan G. T.
    Ma, Sunyoung
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (04) : 381 - 391
  • [46] Biomechanical behavior of the dental implant macrodesign in mandibular implant-supported overdentures
    Okkan, G. S.
    Kucukkurt, S.
    Terzioglu, H.
    Mollaoglu, N.
    JOURNAL OF OSSEOINTEGRATION, 2021, 13 (04) : 234 - 241
  • [47] Attachment systems for mandibular implant-supported overdentures: A systematic review and meta-analysis of randomized controlled trials
    Prasad, Soni
    Faverani, Leonardo P.
    Santiago, Joel Ferreira
    Sukotjo, Cortino
    Yuan, Judy Chia-Chun
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (02): : 354 - 368
  • [48] Efficacy of rehabilitation with different approaches of implant-supported full-arch prosthetic designs: A systematic review
    Ramanauskaite, Ausra
    Becker, Kathrin
    Wolfart, Stefan
    Lukman, Fanya
    Schwarz, Frank
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2022, 49 : 272 - 290
  • [49] Single-Tray Impression Technique for Implant-Supported Overdentures
    Alqahtani, Fawaz
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (05) : 609 - 611
  • [50] Fiber-reinforced composite framework for implant-supported overdentures
    Duncan, JP
    Freilich, MA
    Latvis, CJ
    JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (02): : 200 - 204