Tear changes in contact lens wearers following overnight eye closure

被引:33
作者
Stapleton, F [1 ]
Willcox, MDP
Morris, CA
Sweeney, DF
机构
[1] Univ New S Wales, Cooperat Res Ctr Eye Res & Technol, Sydney, NSW 2052, Australia
[2] Univ New S Wales, Sch Optometry, Cornea & Contact Lens Res Unit, Sydney, NSW 2052, Australia
关键词
contact lenses; tears; eye closure; secretory IgA; complement;
D O I
10.1076/ceyr.17.2.183.5597
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. Tear protein composition alters during eye closure, by becoming rich in secretory IgA (sIgA) and certain complement proteins. This may reflect altered ocular defense mechanisms during eye closure. Since overnight wear of contact lenses (CLs) is associated with an increased risk of corneal infection and inflammation, this study aimed to quantify tear protein changes with overnight soft CL wear. Methods. Non-stimulated tears were collected from 9 CL wearers prior to CL wear (baseline), after daily CL wear, and after 8 h sleep. Lenses were removed following wear and were extracted in 80% urea at 95 degrees C. Secretory IgA, complement C3 and C4, were measured using ELISA and total protein using the Pierce BCA assay. Assays were performed on tear samples and CL extracts. Results. Baseline tear protein concentrations were: 0 total tear protein (9.37 +/- 2.97 mg/mL), C3 (4.4 +/- 2.1 mu g/mL), C4 (0.1 +/- 0.1 mu g/mL), and sIgA (0.84 +/- 0.34 mg/mL). There were no differences in any protein levels between daily CL wear and no CL wear (p > 0.05). Following sleep, protein concentrations were: total tear protein (43.64 +/- 24.30 mg/mL), C3 (72.5 +/- 49.9 mu g/mL), C4 (6.7 +/- 5.2 mu g/mL), and sIgA (5.53 +/- 5.15 mg/mL). Total protein extracted from CLs after daily wear was 90 +/- 27 mu g/CL and, after overnight wear, 152 +/- 24 mu g/CL. Negligible levels of C3, C4 and sIgA were recovered from CL extracts. Uncomplicated daily use of soft CLs does not appear to alter certain tear proteins compared with baseline levels. Uptake of these proteins by the CL does not appear to deplete the tear protein levels. Overnight levels of all tear proteins were increased, compared to daily CL wear.
引用
收藏
页码:183 / 188
页数:6
相关论文
共 50 条
[41]   Microbial contamination of contact lenses and lens care accessories of soft contact lens wearers (university students) in Hong Kong [J].
Yung, M. S. ;
Boost, M. ;
Cho, P. ;
Yap, M. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2007, 27 (01) :11-21
[42]   Tear Film Break-Up Time before and after Watching a VR Video: Comparison between Naked Eyes and Contact Lens Wearers [J].
Kim, Hyunjin ;
Gil, Minji ;
Kang, Hyungoo .
ELECTRONICS, 2024, 13 (13)
[43]   Tear proteins in health, disease, and contact lens wear [J].
Sariri, R. ;
Ghafoori, H. .
BIOCHEMISTRY-MOSCOW, 2008, 73 (04) :381-392
[44]   Tear proteins in health, disease, and contact lens wear [J].
R. Sariri ;
H. Ghafoori .
Biochemistry (Moscow), 2008, 73 :381-392
[45]   Tear film dynamics of a new soft contact lens [J].
Buch, John ;
Riederer, Donald ;
Scales, Charles ;
Xu, Jie .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2023, 43 (05) :1070-1078
[46]   Effects of contact lens wear on tear inflammatory biomarkers [J].
Pereira, Eduardo Insua ;
Sampaio, Ana Paula ;
Lira, Madalena .
CONTACT LENS & ANTERIOR EYE, 2022, 45 (05)
[47]   Potentially Pathogenic Free-Living Amoebae in Contact Lenses of the Asymptomatic Contact Lens Wearers [J].
Niyyati, Maryam ;
Rahimi, Firoozeh ;
Lasejerdi, Zohreh ;
Rezaeian, Mostafa .
IRANIAN JOURNAL OF PARASITOLOGY, 2014, 9 (01) :14-19
[48]   Tear film evaluation and management in soft contact lens wear: a systematic approach [J].
Downie, Laura E. ;
Craig, Jennifer P. .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2017, 100 (05) :438-458
[49]   The TFOS International Workshop on Contact Lens Discomfort: Report of the Contact Lens Interactions With the Tear Film Subcommittee [J].
Craig, Jennifer P. ;
Willcox, Mark D. P. ;
Argueeso, Pablo ;
Maissa, Cecile ;
Stahl, Ulrike ;
Tomlinson, Alan ;
Wang, Jianhua ;
Yokoi, Norihiko ;
Stapleton, Fiona .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (11) :123-156
[50]   Ocular and Visual Alterations in Computer Workers Contact Lens Wearers: Scoping Review [J].
Tauste Frances, Ana ;
Ronda-Perez, Elena ;
Segui Crespo, Maria del Mar .
REVISTA ESPANOLA DE SALUD PUBLICA, 2014, 88 (02) :203-215