Tear changes in contact lens wearers following overnight eye closure

被引:33
作者
Stapleton, F [1 ]
Willcox, MDP
Morris, CA
Sweeney, DF
机构
[1] Univ New S Wales, Cooperat Res Ctr Eye Res & Technol, Sydney, NSW 2052, Australia
[2] Univ New S Wales, Sch Optometry, Cornea & Contact Lens Res Unit, Sydney, NSW 2052, Australia
关键词
contact lenses; tears; eye closure; secretory IgA; complement;
D O I
10.1076/ceyr.17.2.183.5597
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. Tear protein composition alters during eye closure, by becoming rich in secretory IgA (sIgA) and certain complement proteins. This may reflect altered ocular defense mechanisms during eye closure. Since overnight wear of contact lenses (CLs) is associated with an increased risk of corneal infection and inflammation, this study aimed to quantify tear protein changes with overnight soft CL wear. Methods. Non-stimulated tears were collected from 9 CL wearers prior to CL wear (baseline), after daily CL wear, and after 8 h sleep. Lenses were removed following wear and were extracted in 80% urea at 95 degrees C. Secretory IgA, complement C3 and C4, were measured using ELISA and total protein using the Pierce BCA assay. Assays were performed on tear samples and CL extracts. Results. Baseline tear protein concentrations were: 0 total tear protein (9.37 +/- 2.97 mg/mL), C3 (4.4 +/- 2.1 mu g/mL), C4 (0.1 +/- 0.1 mu g/mL), and sIgA (0.84 +/- 0.34 mg/mL). There were no differences in any protein levels between daily CL wear and no CL wear (p > 0.05). Following sleep, protein concentrations were: total tear protein (43.64 +/- 24.30 mg/mL), C3 (72.5 +/- 49.9 mu g/mL), C4 (6.7 +/- 5.2 mu g/mL), and sIgA (5.53 +/- 5.15 mg/mL). Total protein extracted from CLs after daily wear was 90 +/- 27 mu g/CL and, after overnight wear, 152 +/- 24 mu g/CL. Negligible levels of C3, C4 and sIgA were recovered from CL extracts. Uncomplicated daily use of soft CLs does not appear to alter certain tear proteins compared with baseline levels. Uptake of these proteins by the CL does not appear to deplete the tear protein levels. Overnight levels of all tear proteins were increased, compared to daily CL wear.
引用
收藏
页码:183 / 188
页数:6
相关论文
共 50 条
  • [21] A Survey of Presbyopic Contact Lens Wearers in a University Setting
    Rueff, Erin M.
    Varghese, Robin Joy
    Brack, Taylor M.
    Downard, Danica E.
    Bailey, Melissa D.
    OPTOMETRY AND VISION SCIENCE, 2016, 93 (08) : 848 - 854
  • [22] Mechanisms for the symptoms of dryness in soft contact lens wearers
    McMonnies, Charles W.
    EXPERT REVIEW OF OPHTHALMOLOGY, 2023, 18 (05) : 327 - 335
  • [23] Investigation of Delefilcon A Contact Lenses for Symptomatic Daily Disposable Contact Lens Wearers with Dry Eye Disease: A Prospective Comparative Study
    Guthrie, Sarah E.
    Luensmann, Doerte
    Schulze, Marc-Matthias
    Woods, Jill
    Jones, Lyndon
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 2999 - 3008
  • [24] Contact Lens-Induced Discomfort and Inflammatory Mediator Changes in Tears
    Masoudi, Simin
    Zhao, Zhenjun
    Stapleton, Fiona
    Willcox, Mark
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2017, 43 (01): : 40 - 45
  • [25] The effect of eye closure on protein and complement deposition on Group IV hydrogel contact lenses: Relationship to tear flow dynamics
    Sack, RA
    Sathe, S
    Hackworth, LA
    Willcox, MDP
    Holden, BA
    Morris, CA
    CURRENT EYE RESEARCH, 1996, 15 (11) : 1092 - 1100
  • [26] Differences between tears of contact lens wearers studied by photon correlation spectroscopy
    Picarazzi, S.
    Bergamaschi, D.
    Tavazzi, S.
    CONTACT LENS & ANTERIOR EYE, 2019, 42 (02) : 212 - 215
  • [27] A measure of tear inflow in habitual scleral lens wearers with and without midday fogging
    Skidmore, Kelsea, V
    Walker, Maria K.
    Marsack, Jason D.
    Bergmanson, Jan P. G.
    Miller, William L.
    CONTACT LENS & ANTERIOR EYE, 2019, 42 (01) : 36 - 42
  • [28] A multi-centre study of lapsed contact lens wearers
    Young, G
    Veys, J
    Pritchard, N
    Coleman, S
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2002, 22 (06) : 516 - 527
  • [29] Customer loyalty among daily disposable contact lens wearers
    Patel, Neelam I.
    Naroo, Shehzad A.
    Eperjesi, Frank
    Rumney, Nicholas J.
    CONTACT LENS & ANTERIOR EYE, 2015, 38 (01) : 15 - 20
  • [30] Preinflammatory Signs in Established Reusable and Disposable Contact Lens Wearers
    Chao, Cecilia
    Stapleton, Fiona
    Willcox, Mark D. P.
    Golebiowski, Blanka
    Richdale, Kathryn
    OPTOMETRY AND VISION SCIENCE, 2017, 94 (11) : 1003 - 1008