Tear changes in contact lens wearers following overnight eye closure

被引:33
|
作者
Stapleton, F [1 ]
Willcox, MDP
Morris, CA
Sweeney, DF
机构
[1] Univ New S Wales, Cooperat Res Ctr Eye Res & Technol, Sydney, NSW 2052, Australia
[2] Univ New S Wales, Sch Optometry, Cornea & Contact Lens Res Unit, Sydney, NSW 2052, Australia
关键词
contact lenses; tears; eye closure; secretory IgA; complement;
D O I
10.1076/ceyr.17.2.183.5597
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. Tear protein composition alters during eye closure, by becoming rich in secretory IgA (sIgA) and certain complement proteins. This may reflect altered ocular defense mechanisms during eye closure. Since overnight wear of contact lenses (CLs) is associated with an increased risk of corneal infection and inflammation, this study aimed to quantify tear protein changes with overnight soft CL wear. Methods. Non-stimulated tears were collected from 9 CL wearers prior to CL wear (baseline), after daily CL wear, and after 8 h sleep. Lenses were removed following wear and were extracted in 80% urea at 95 degrees C. Secretory IgA, complement C3 and C4, were measured using ELISA and total protein using the Pierce BCA assay. Assays were performed on tear samples and CL extracts. Results. Baseline tear protein concentrations were: 0 total tear protein (9.37 +/- 2.97 mg/mL), C3 (4.4 +/- 2.1 mu g/mL), C4 (0.1 +/- 0.1 mu g/mL), and sIgA (0.84 +/- 0.34 mg/mL). There were no differences in any protein levels between daily CL wear and no CL wear (p > 0.05). Following sleep, protein concentrations were: total tear protein (43.64 +/- 24.30 mg/mL), C3 (72.5 +/- 49.9 mu g/mL), C4 (6.7 +/- 5.2 mu g/mL), and sIgA (5.53 +/- 5.15 mg/mL). Total protein extracted from CLs after daily wear was 90 +/- 27 mu g/CL and, after overnight wear, 152 +/- 24 mu g/CL. Negligible levels of C3, C4 and sIgA were recovered from CL extracts. Uncomplicated daily use of soft CLs does not appear to alter certain tear proteins compared with baseline levels. Uptake of these proteins by the CL does not appear to deplete the tear protein levels. Overnight levels of all tear proteins were increased, compared to daily CL wear.
引用
收藏
页码:183 / 188
页数:6
相关论文
共 50 条
  • [1] Decreased mucin concentrations in tear fluids of contact lens wearers
    Yasueda, S
    Yamakawa, K
    Nakanishi, Y
    Kinoshita, M
    Kakehi, K
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (1-2) : 187 - 195
  • [2] Dry Eye in Pediatric Contact Lens Wearers
    Greiner, Katie L.
    Walline, Jeffrey J.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2010, 36 (06): : 352 - 355
  • [3] Tear Menisci after Overnight Contact Lens Wear
    Tao, Aizhu
    Cai, Chunyan
    Shen, Meixiao
    Wang, Jianhua
    Chen, Zhao
    Xu, Suzhong
    Li, Ming
    Lu, Fan
    OPTOMETRY AND VISION SCIENCE, 2011, 88 (12) : 1433 - 1438
  • [4] Responses of contact lens wearers to a dry eye survey
    Begley, CG
    Caffery, B
    Nichols, KK
    Chalmers, R
    OPTOMETRY AND VISION SCIENCE, 2000, 77 (01) : 40 - 46
  • [5] Tear proteomic analysis of young glasses, orthokeratology, and soft contact lens wearers
    Qin, Guoting
    Chao, Cecilia
    Lattery, Lauren J.
    Lin, Hong
    Fu, Wenjiang
    Richdale, Kathryn
    Cai, Chengzhi
    JOURNAL OF PROTEOMICS, 2023, 270
  • [6] Immunoglobulin a antibodies against Pseudomonas aeruginosa in the tear fluid of contact lens wearers
    Cheng, KH
    Spanjaard, L
    Rutten, H
    Dankert, JI
    Polak, BCP
    Kijlstra, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (10) : 2081 - 2088
  • [7] The effect of eye closure on the post-lens tear film thickness during silicone hydrogel contact lens wear
    Nichols, JJ
    King-Smith, PE
    CORNEA, 2003, 22 (06) : 539 - 544
  • [8] Ocular surface and tear film status among contact lens wearers and non-wearers who use VDT at work: comparing three different lens types
    Tauste, Ana
    Ronda, Elena
    Baste, Valborg
    Bratveit, Magne
    Moen, Bente E.
    Segui Crespo, Maria-del-Mar
    INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2018, 91 (03) : 327 - 335
  • [9] Ocular surface and tear film status among contact lens wearers and non-wearers who use VDT at work: comparing three different lens types
    Ana Tauste
    Elena Ronda
    Valborg Baste
    Magne Bråtveit
    Bente E. Moen
    María-del-Mar Seguí Crespo
    International Archives of Occupational and Environmental Health, 2018, 91 : 327 - 335
  • [10] Association Between Ocular Surface Temperature and Tear Film Stability in Soft Contact Lens Wearers
    Itokawa, Takashi
    Okajima, Yukinobu
    Suzuki, Takashi
    Kakisu, Koji
    Iwashita, Hiroko
    Murakami, Yoshitaka
    Hori, Yuichi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (02) : 771 - 775