Characterization of petroleum using near-infrared spectroscopy: Quantitative modeling for the true boiling point curve and specific gravity

被引:89
作者
Pasquini, Cello
Bueno, Aerenton Ferreira
机构
[1] Univ Estadual Campinas, Inst Quim, BR-13084971 Campinas, SP, Brazil
[2] REVAP, Petrobras Refinaria Henrique Lage, BR-12223900 Sao Jose Dos Campos, Brazil
关键词
petroleum characterization; API gravity; true boiling point curve; near-infrared spectroscopy;
D O I
10.1016/j.fuel.2006.12.026
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This work describes a new approach to predict the true boiling point (TBP) curve and to estimate the API gravity in order to characterize the petroleum processed in refineries by using the information present in its absorbance spectrum obtained in the near-infrared region (NIR). The absorbance spectra were obtained in the range from 3700 to 10000 cm(-1) employing a CaF2 transmittance cell with a 0.5 mm light path. Three spectral regions were evaluated for modeling purpose: 5000-3900 cm(-1), 6000-3700 cm(-1), and 9000-700 cm(-1). The spectral region corresponding to the combination of C-H vibrations produces absorption spectra with very good quality while the region above 6500 cm(-1) is dominated by scattering of the radiation. The absorbance spectra of a total of 122 samples of petroleum and petroleum blends coming from various producing regions in Brazil and abroad were obtained and pre-processed to correct for base line shift and for the integrated area. Two approaches were employed to obtain the models: one using artificial neural networks (ANN) and the other using partial least squares (PLS). The results showed that PLS gives better predictions than ANN for the API gravity and the TBP curve. The best results were obtained using the 5000-3900 cm(-1) spectral range. In an external validation, the average RMSEP for the volume of distillate along the TBP curve employing PLS model was 1.13V% while that for API gravity was 0.24. A comparison between the results obtained by a simulator used by the refinery and the PLS model revealed a better performance for the model based on NIR spectrometry. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1927 / 1934
页数:8
相关论文
共 23 条
[11]  
Esbensen K. H., 2002, MULTIVARIATE DATA AN
[12]   Analysis of gasolines by FT-IR spectroscopy [J].
Fodor, GE ;
Kohl, KB ;
Mason, RL .
ANALYTICAL CHEMISTRY, 1996, 68 (01) :23-30
[13]  
FOULK SJ, 1992, PROCESS CONTR QUAL, V2, P69
[14]  
GUCHARDI R, 1998, J NEAR INFRARED SPEC, V6, P333
[15]   Quality characterisation of crude oils by partial least square calibration of NIR spectral profiles [J].
Hidajat, K ;
Chong, SM .
JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2000, 8 (01) :53-59
[16]  
INHO C, 2000, Patent No. 0039561
[17]   Crude oil model emulsion characterised by means of near infrared spectroscopy and multivariate techniques [J].
Kallevik, H ;
Hansen, SB ;
Sæther, O ;
Kvalheim, OM ;
Sjöblom, J .
JOURNAL OF DISPERSION SCIENCE AND TECHNOLOGY, 2000, 21 (03) :245-262
[18]   RAPID SPECTROSCOPIC DETERMINATION OF PER CENT AROMATICS, PER CENT SATURATES AND FREEZING-POINT OF JP-4 AVIATION FUEL [J].
LYSAGHT, MJ ;
KELLY, JJ ;
CALLIS, JB .
FUEL, 1993, 72 (05) :623-631
[19]   204 years of near infrared technology: 1800-2003 [J].
McClure, WF .
JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2003, 11 (06) :487-518
[20]   Near infrared spectroscopy: Fundamentals, practical aspects and analytical applications [J].
Pasquini, C .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2003, 14 (02) :198-219