Impact of annular and supra-annular CoreValve deployment locations on aortic and coronary artery hemodynamics

被引:41
作者
Kandail, Harkamaljot S. [1 ,2 ]
Trivedi, Setu D. [3 ]
Shaikh, Armaan C. [3 ]
Bajwa, Tanvir K. [3 ]
O'Hair, Daniel P. [3 ]
Jahangir, Arshad [3 ]
LaDisa, John F., Jr. [1 ,2 ,4 ]
机构
[1] Marquette Univ, Dept Biomed Engn, Milwaukee, WI 53233 USA
[2] Med Coll Wisconsin, Milwaukee, WI 53226 USA
[3] Aurora St Lukes Med Ctr, Aurora Cardiovasc Serv, Milwaukee, WI USA
[4] Med Coll Wisconsin, Dept Med, Div Cardiovasc Med, Milwaukee, WI 53226 USA
关键词
Transcatheter aortic valve replacement; Finite element analysis; Fluid-structure interaction; Computational fluid dynamics; Atherosclerosis; Aneurysm; Coronary artery disease; Cardiovascular disease; FLUID-STRUCTURE INTERACTION; PERCUTANEOUS TRANSCATHETER IMPLANTATION; IN-VALVE IMPLANTATION; BLOOD STASIS; PROSTHESIS; FLOW; REPLACEMENT; STENOSIS; SURGERY; MODEL;
D O I
10.1016/j.jmbbm.2018.06.032
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
CoreValve is widely used in transcatheter aortic valve replacement, but the impact of its deployment location on hemodynamics is unexplored despite a potential role in subsequent aortic and coronary artery pathologies. The objectives of this investigation were to perform fluid-structure interaction (FSI) simulations for a 29 mm CoreValve deployed in annular vs supra-annular locations, and characterize resulting hemodynamics including velocity and wall shear stress (WSS). Patient-specific geometry was reconstructed from computed tomography scans and CoreValve was deployed using a finite element approach. FSI simulations were then performed using a boundary conforming method and realistic boundary conditions. Results showed that CoreValve deployment location impacts hemodynamics in the ascending aorta and flow patterns in the coronary arteries. During peak systole, annularly deployed CoreValve produced a jet-like flow structure impinging on the outer-curvature of the ascending aorta. Supra-annularly deployed CoreValve having a lateral tilt of 10 led to a more centered jet impinging further downstream. At mid-systole, valve leaflets of the annularly deployed CoreValve closed asymmetrically leading to disorganized flow patterns in the ascending aorta vs those from the supra-annular position. Supra-annularly deployed CoreValve also led to high-velocity para-valvular flow supplying the coronary arteries. CoreValve in the supra-annular position significantly (P < 0.05) elevated WSS within the first few diameters of both coronary arteries as compared to the annular position for many time points quantified. These results afforded by the advanced simulation methods may have important clinical implications given the role of aortic hemodynamics in dilation and the pro-atherogenic nature of WSS alterations in the coronary arteries.
引用
收藏
页码:131 / 142
页数:12
相关论文
共 49 条
[1]   Incidence, feasibility and outcome of percutaneous coronary intervention after transcatheter aortic valve implantation with a self-expanding prosthesis. Results from a single center experience [J].
Allali, Abdelhakim ;
El-Mawardy, Mohamed ;
Schwarz, Bettina ;
Sato, Takao ;
Geist, Volker ;
Toelg, Ralph ;
Richardt, Gert ;
Abdel-Wahab, Mohamed .
CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2016, 17 (06) :391-398
[2]   Incidence and predictors of coronary obstruction following transcatheter aortic valve implantation in the real world [J].
Arai, Takahide ;
Lefevre, Thierry ;
Hovasse, Thomas ;
Garot, Philippe ;
Benamer, Hakim ;
Unterseeh, Thierry ;
Roy, Andrew K. ;
Romano, Mauro ;
Hayashida, Kentaro ;
Watanabe, Yusuke ;
Bouvier, Erik ;
Morice, Marie-Claude ;
Chevalier, Bernard .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (07) :1192-1197
[3]   Comparison of echocardiographic abnormalities in African-American, Hispanic, and white men and women aged &gt;60 years [J].
Aronow, WS ;
Ahn, C ;
Kronzon, I .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (09) :1131-1133
[4]  
Bach DS, 2007, J HEART VALVE DIS, V16, P362
[5]   Fluid-Structure Interaction Simulation of Prosthetic Aortic Valves: Comparison between Immersed Boundary and Arbitrary Lagrangian-Eulerian Techniques for the Mesh Representation [J].
Bavo, Alessandra M. ;
Rocatello, Giorgia ;
Iannaccone, Francesco ;
Degroote, Joris ;
Vierendeels, Jan ;
Segers, Patrick .
PLOS ONE, 2016, 11 (04)
[6]  
Benjamin EJ, 2018, CIRCULATION, V137, pE67, DOI [10.1161/CIR.0000000000000558, 10.1161/CIR.0000000000000485, 10.1161/CIR.0000000000000530]
[7]   LEFT MAIN CORONARY-ARTERY DISEASE - ASSESSMENT, DIAGNOSIS, AND THERAPY [J].
BERGELSON, BA ;
TOMMASO, CL .
AMERICAN HEART JOURNAL, 1995, 129 (02) :350-359
[8]   Blood flow and coherent vortices in the normal and aneurysmatic aortas: a fluid dynamical approach to intraluminal thrombus formation [J].
Biasetti, Jacopo ;
Hussain, Fazle ;
Gasser, T. Christian .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2011, 8 (63) :1449-1461
[9]   Challenges of coronary angiography and intervention in patients previously treated by TAVI [J].
Blumenstein, Johannes ;
Kim, Won-Keun ;
Liebetrau, Christoph ;
Gaede, Luise ;
Kempfert, Joerg ;
Walther, Thomas ;
Hamm, Christian ;
Moellmann, Helge .
CLINICAL RESEARCH IN CARDIOLOGY, 2015, 104 (08) :632-639