Intracoronary radiation therapy improves the clinical and angiographic outcomes of diffuse in-stent restenotic lesions - Results of the Washington Radiation for In- Stent Restenosis Trial for long lesions (Long WRIST) studies

被引:75
|
作者
Waksman, R
Cheneau, E
Ajani, AE
White, RL
Pinnow, E
Torguson, R
Deible, R
Satler, LF
Pichard, AD
Kent, KM
Teirstein, PS
Lindsay, J
机构
[1] Washington Hosp Ctr, Washington, DC 20010 USA
[2] SCRIPPS Clin, La Jolla, CA USA
关键词
brachytherapy; restenosis; lesion; radiation;
D O I
10.1161/01.CIR.0000060497.91775.6D
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The Washington Radiation for In-Stent Restenosis Trial for long lesions (Long WRIST) was designed to determine the safety and efficacy of vascular brachytherapy for the treatment of diffuse in-stent restenosis. Methods and Results-A total of 120 patients with diffuse in-stent restenosis in native coronary arteries (lesion length, 36 to 80 mm) were randomized for either radiation with Ir-192 with 15 Gy at 2 mm from the source axis or placebo. After enrollment, 120 additional patients with the same inclusion criteria were treated with Ir-192 with 18 Gy and included in the Long WRIST High Dose registry. Antiplatelet therapy was initially prescribed for 1 month and was extended to 6 months in the last 60 patients of the Long WRIST High Dose registry. At 6 months, the binary angiographic restenosis rate was 73%, 45%, and 38% in the placebo, 15 Gy, and 18 Gy radiated groups, respectively (P<0.05). At 1 year, the primary clinical end point of major cardiac events was 63% in the placebo group and 42% in the radiated group with 15 Gy (P<0.05). The major cardiac event rate was further reduced with 18 Gy (22%; P<0.05 versus 15 Gy). Late thrombosis was 12%, 15%, and 9% in the placebo group, 15 Gy group with 1 month of antiplatelet therapy, and 18 Gy group with 6 months of antiplatelet therapy, respectively. Conclusions-Vascular brachytherapy with Ir-192 is safe and reduces the rate of recurrent restenosis in diffuse in-stent restenosis. The efficacy of vascular brachytherapy on angiographic and clinical outcomes is enhanced with a radiation dose of 18 Gy and prolonged antiplatelet therapy.
引用
收藏
页码:1744 / 1749
页数:6
相关论文
共 24 条
  • [1] Combined cutting balloon angioplasty and intracoronary beta radiation for treatment of in-stent restenosis: Clinical outcomes and effect of pullback radiation for long lesions
    Moustapha, A
    Salloum, J
    Saikia, S
    Awadallah, H
    Ghani, M
    Sdringola, S
    Schroth, G
    Assali, A
    Smalling, RW
    Anderson, HV
    Rosales, O
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 57 (03) : 325 - 329
  • [2] Serial intravascular ultrasound of intracoronary γ-radiation assessment of the efficacy therapy for preventing recurrence in very long, diffuse, in-stent restenosis lesions
    Ahmed, JM
    Mintz, GS
    Waksman, R
    Mehran, R
    Leiboff, B
    Pichard, AD
    Satler, LF
    Kent, KM
    Weissman, NJ
    CIRCULATION, 2001, 104 (08) : 856 - 859
  • [3] Impact of intracoronary radiation on in-stent restenosis involving ostial lesions
    Ajani, AE
    Waksman, R
    Cheneau, E
    Leborgne, L
    Pinnow, E
    Canos, DA
    Satler, LF
    Pichard, AD
    Kent, KM
    Lindsay, J
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (02) : 175 - 180
  • [4] Prolonged antiplatelet therapy to prevent late thrombosis after intracoronary γ-radiation in patients with in-stent restenosis -: Washington Radiation for In-Stent Restenosis Trial PLUS 6 months of clopidogrel (WRIST PLUS)
    Waksman, R
    Ajani, AE
    White, RL
    Pinnow, E
    Dieble, R
    Bui, AB
    Taaffe, M
    Gruberg, L
    Mintz, GS
    Satler, LF
    Pichard, AD
    Kent, KK
    Lindsay, J
    CIRCULATION, 2001, 103 (19) : 2332 - 2335
  • [5] Intracoronary radiation therapy using a novel beta emitter for in-stent restenosis Tungsten WRIST
    Dilcher, Christian
    Satler, Lowell F.
    Pichard, Augusto D.
    Kent, Kenneth M.
    Porrazzo, Michael
    Chan, Rosanna
    Torguson, Rebecca
    Canos, Daniel A.
    Waksman, Ron
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2005, 6 (02) : 52 - 57
  • [6] Gamma radiation for in-stent restenosis: Effect of lesion length on angiographic and clinical outcomes
    Mehran, R
    Dangas, G
    Lansky, AJ
    Stone, GW
    Mintz, GS
    Kent, KM
    Pichard, AD
    Satler, LF
    Fahy, M
    Leon, MB
    Waksman, R
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 61 (03) : 354 - 359
  • [7] Twelve versus six months of clopidogrel to reduce major cardiac events in patients undergoing γ-radiation therapy for in-stent restenosis -: Washington radiation for in-stent restenosis trial (WRIST) 12 versus WRIST PLUS
    Waksman, R
    Ajani, AE
    Pinnow, E
    Cheneau, E
    Leborgne, L
    Dieble, R
    Bui, AB
    Satler, LF
    Pichard, AD
    Kent, KK
    Lindsay, J
    CIRCULATION, 2002, 106 (07) : 776 - 778
  • [8] Favorable effect of γ-radiation for in-stent restenosis:: Effect of diabetes on angiographic and clinical outcomes
    Iakovou, L
    Mehran, R
    Dangas, G
    Lansky, AJ
    Stone, GW
    Mintz, GS
    Aymong, E
    Ashby, DT
    Pichard, AD
    Satler, LF
    Kent, K
    Leon, MB
    Waksman, R
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 62 (03) : 303 - 307
  • [9] Intracoronary radiation therapy for multi-drug resistant in-stent restenosis: Initial clinical experience
    Price, Matthew J.
    Giap, Huan
    Teirstein, Paul S.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (01) : 132 - 134
  • [10] Treatment of in-stent restenosis using a paclitaxel-eluting stent:: acute results and long-term follow-up of a matched-pair comparison with intracoronary β-radiation therapy
    Radke, PW
    Kobella, S
    Kaiser, A
    Franke, A
    Schubert, D
    Grube, E
    Hanrath, P
    Hoffman, R
    EUROPEAN HEART JOURNAL, 2004, 25 (11) : 920 - 925