Case report: percutaneous closure of residual leak following left atrial appendage occlusion

被引:3
作者
Suradi, Hussam S. [1 ]
Park, Jeffrey [1 ]
Poulin, Marie-France [1 ]
Kavinsky, Clifford J. [1 ]
机构
[1] Rush Univ, Div Cardiovasc Med, Med Ctr, 1717 W Congress Pkwy,Kellogg 317, Chicago, IL 60612 USA
关键词
Case report; Atrial fibrillation; Watchman; Stroke; Peri-device leak; DEVICE; OUTCOMES; IMPACT;
D O I
10.1093/ehjcr/ytaa139
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Transcatheter left atrial appendage occlusion (LAAO) using Watchman device has been demonstrated to be efficacious in decreasing stroke risk in patients with atrial fibrillation who are not suitable for long-term anticoagulation. Residual leaks are frequently encountered following LAAO procedures and their clinical implications and optimal management remain controversial. Case summary In this report, we describe a case of peri-Watchman device leak treated successfully with percutaneous device closure using an Amplatzer Vascular Plug II device. Discussion The clinical implications of peri-device leaks remain controversial with general consensus to continue anticoagulation along with serial imaging for larger leaks (>5 mm). As an alternative strategy, percutaneous closure of these leaks has been attempted in hope of avoiding anticoagulation and minimizing the risk of stroke and should be studied further.
引用
收藏
页码:1 / 4
页数:4
相关论文
共 7 条
  • [1] Percutaneous Closure of Peridevice Leak After Left Atrial Appendage Occlusion
    Alkhouli, Mohamad
    Alqahtani, Fahad
    Kazienko, Brian
    Olgers, Kassandra
    Sengupta, Partho P.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (11) : E83 - E85
  • [2] Left atrial appendage closure with the Amplatzer™ Cardiac Plug: Impact of shape and device sizing on follow-up leaks
    Freixa, Xavier
    Tzikas, Apostolos
    Sobrino, Ayax
    Chan, Jason
    Basmadjian, Arsene J.
    Ibrahim, Reda
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (02) : 1023 - 1027
  • [3] Catheter-Based Closure of Residual Leaks After Percutaneous Occlusion of the Left Atrial Appendage
    Hornung, Marius
    Gafoor, Sameer
    Id, Dani
    Vaskelyte, Laura
    Hofmann, Ilona
    Franke, Jennifer
    Sievert, Horst
    Bertog, Stefan C.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 87 (07) : 1324 - 1330
  • [4] 5-Year Outcomes After Left Atrial Appendage Closure From the PREVAIL and PROTECT AF Trials
    Reddy, Vivek Y.
    Doshi, Shephal K.
    Kar, Saibal
    Gibson, Douglas N.
    Price, Matthew J.
    Huber, Kenneth
    Horton, Rodney P.
    Buchbinder, Maurice
    Neuzil, Petr
    Gordon, Nicole T.
    Holmes, David R., Jr.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (24) : 2964 - 2975
  • [5] Left atrial appendage closure: outcomes and challenges
    Suradi, H. S.
    Hijazi, Z. M.
    [J]. NETHERLANDS HEART JOURNAL, 2017, 25 (02) : 143 - 151
  • [6] The Clinical Impact of Incomplete Left Atrial Appendage Closure With the Watchman Device in Patients With Atrial Fibrillation
    Viles-Gonzalez, Juan F.
    Kar, Saibal
    Douglas, Pamela
    Dukkipati, Srinivas
    Feldman, Ted
    Horton, Rodney
    Holmes, David
    Reddy, Vivek Y.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (10) : 923 - 929
  • [7] Incomplete occlusion of the left atrial appendage with the percutaneous left atrial appendage transcatheter occlusion device is not associated with increased risk of stroke
    Viles-Gonzalez, Juan F.
    Reddy, Vivek Y.
    Petru, Jan
    Mraz, Tomas
    Grossova, Zuzana
    Kralovec, Stepan
    Neuzil, Petr
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 33 (01) : 69 - 75