Comparison of Internal Anterior Chamber Diameter Imaging Modalities: 35-MHz Ultrasound Biomicroscopy, Visante Optical Coherence Tomography, and Pentacam

被引:15
作者
Kim, Sang-Kyoon [1 ]
Kim, Hyo-Myung [1 ]
Song, Jong-Suk [1 ]
机构
[1] Korea Univ, Coll Med, Guro Hosp, Dept Ophthalmol, Seoul 152703, South Korea
关键词
PHAKIC INTRAOCULAR LENSES; ROTATING SCHEIMPFLUG CAMERA; HIGH-FREQUENCY ULTRASOUND; CORNEAL THICKNESS; SEGMENT; MYOPIA; DIOPTERS; DEPTH; EYES;
D O I
10.3928/1081597X-20100121-07
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the internal diameter of the anterior chamber among three different imaging modalities: 35-MHz ultrasound biomicroscopy (UBM), Visante optical coherence tomography (OCT), and Pentacam, and to compare the internal diameters with white-to-white (WTW) distance measured by Orbscan. METHODS: The internal horizontal anterior chamber diameter was measured in 20 normal eyes using 35-MHz UBM (Optikon), Visante OCT (Carl Zeiss Meditec), and Pentacam (Oculus Inc). The mean horizontal anterior chamber diameters were compared, and the correlations between each pair of two different methods were evaluated. Horizontal WTW distance was measured by Orbscan Ilz (Bausch & Lomb-Orbtek Inc) and then correlated with the measurements of internal anterior chamber diameter. RESULTS: The mean horizontal anterior chamber diameter was 10.99 +/- 0.47 mm with UBM, 11.70 +/- 0.47 mm with OCT, and 11.86 +/- 0.45 mm with Pentacam. Ultrasound biomicroscopy measurements were significantly different than those of OCT and Pentacam (P<.001 for both). However, no significant difference was found between OCT and Pentacam (P=.19). Regarding the correlations between each pair of two different methods, UBM and OCT showed significant correlation (r=0.848, P<.001), but there was no significant correlation between OCT and Pentacam (r=0.403, P=.078), even though the mean values were similar. In the Bland-Altman plots, the range of agreement was 0.51 mm between OCT and UBM, and 0.99 mm between Pentacam and OCT. CONCLUSIONS: Although the internal anterior chamber diameters measured by 35-MHz UBM were significantly smaller than those measured by Visante OCT and Pentacam, the measurements of UBM and Visante OCT showed significant correlation and good agreement with each other. Pentacam showed poor correlation with other measurements. [J Refract Surg. 2010;26:120-126.] doi:10.3928/1081597X-20100121-07
引用
收藏
页码:120 / 126
页数:7
相关论文
共 25 条
  • [21] Chronic subclinical inflammation in phakic eyes with intraocular lenses to correct myopia
    PerezSantonja, JJ
    Iradier, MT
    delCastillo, JMB
    Serrano, JM
    Zato, MA
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (02) : 183 - 187
  • [22] Anterior segment biometry with 2 imaging technologies:: Very-high-frequency ultrasound scanning versus optical coherence tomography
    Pinero, David P.
    Plaza, Ana Belen
    Alio, Jorge L.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (01) : 95 - 102
  • [23] Anterior chamber measurements using Pentacam rotating Scheimpflug camera
    Rabsilber, TM
    Khoramnia, R
    Auffarth, GU
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (03) : 456 - 459
  • [24] Real-time optical coherence tomography of the anterior segment at 1310 nm
    Radhakrishnan, S
    Rollins, AM
    Roth, JE
    Yazdanfar, S
    Westphal, V
    Bardenstein, DS
    Izatt, JA
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2001, 119 (08) : 1179 - 1185
  • [25] Advances in anterior segment imaging
    Wolffsohn, James S.
    Davies, Leon N.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2007, 18 (01) : 32 - 38