Comparison of Internal Anterior Chamber Diameter Imaging Modalities: 35-MHz Ultrasound Biomicroscopy, Visante Optical Coherence Tomography, and Pentacam

被引:15
作者
Kim, Sang-Kyoon [1 ]
Kim, Hyo-Myung [1 ]
Song, Jong-Suk [1 ]
机构
[1] Korea Univ, Coll Med, Guro Hosp, Dept Ophthalmol, Seoul 152703, South Korea
关键词
PHAKIC INTRAOCULAR LENSES; ROTATING SCHEIMPFLUG CAMERA; HIGH-FREQUENCY ULTRASOUND; CORNEAL THICKNESS; SEGMENT; MYOPIA; DIOPTERS; DEPTH; EYES;
D O I
10.3928/1081597X-20100121-07
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the internal diameter of the anterior chamber among three different imaging modalities: 35-MHz ultrasound biomicroscopy (UBM), Visante optical coherence tomography (OCT), and Pentacam, and to compare the internal diameters with white-to-white (WTW) distance measured by Orbscan. METHODS: The internal horizontal anterior chamber diameter was measured in 20 normal eyes using 35-MHz UBM (Optikon), Visante OCT (Carl Zeiss Meditec), and Pentacam (Oculus Inc). The mean horizontal anterior chamber diameters were compared, and the correlations between each pair of two different methods were evaluated. Horizontal WTW distance was measured by Orbscan Ilz (Bausch & Lomb-Orbtek Inc) and then correlated with the measurements of internal anterior chamber diameter. RESULTS: The mean horizontal anterior chamber diameter was 10.99 +/- 0.47 mm with UBM, 11.70 +/- 0.47 mm with OCT, and 11.86 +/- 0.45 mm with Pentacam. Ultrasound biomicroscopy measurements were significantly different than those of OCT and Pentacam (P<.001 for both). However, no significant difference was found between OCT and Pentacam (P=.19). Regarding the correlations between each pair of two different methods, UBM and OCT showed significant correlation (r=0.848, P<.001), but there was no significant correlation between OCT and Pentacam (r=0.403, P=.078), even though the mean values were similar. In the Bland-Altman plots, the range of agreement was 0.51 mm between OCT and UBM, and 0.99 mm between Pentacam and OCT. CONCLUSIONS: Although the internal anterior chamber diameters measured by 35-MHz UBM were significantly smaller than those measured by Visante OCT and Pentacam, the measurements of UBM and Visante OCT showed significant correlation and good agreement with each other. Pentacam showed poor correlation with other measurements. [J Refract Surg. 2010;26:120-126.] doi:10.3928/1081597X-20100121-07
引用
收藏
页码:120 / 126
页数:7
相关论文
共 25 条
  • [1] Phakic anterior chamber lenses for the correction of myopia -: A 7-year cumulative analysis in complications in 283 cases
    Alió, JL
    de la Hoz, F
    Pérez-Santonja, JJ
    Ruiz-Moreno, JM
    Quesada, JA
    [J]. OPHTHALMOLOGY, 1999, 106 (03) : 458 - 466
  • [2] Myopic angle-supported intraocular lenses -: Two-year follow-up
    Allemann, N
    Chamon, W
    Tanaka, HM
    Mori, ES
    Campos, M
    Schor, P
    Baïkoff, G
    [J]. OPHTHALMOLOGY, 2000, 107 (08) : 1549 - 1554
  • [3] Apple D J, 2001, Trans Am Ophthalmol Soc, V99, P95
  • [4] Measurement of the internal diameter and depth of the anterior chamber: IOLMaster versus anterior chamber optical coherence tomographer
    Baikoff, G
    Jodai, HJ
    Bourgeon, G
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) : 1722 - 1728
  • [5] Pigment dispersion and Artisan phakic intraocular lenses -: Crystalline lens rise as a safety criterion
    Baïkoff, G
    Bourgeon, G
    Jodai, HJ
    Fontaine, A
    Lellis, FV
    Trinquet, L
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (04) : 674 - 680
  • [6] Baikoff G, 1998, J REFRACT SURG, V14, P282
  • [7] BAIKOFF G, 2000, OPERATIVE TECHNIQUES, V3, P35
  • [8] Anterior segment OCT and phakic intraocular lenses:: A perspective
    Baikoff, Georges
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) : 1827 - 1835
  • [9] Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry
    Barkana, Y
    Gerber, Y
    Elbaz, U
    Schwartz, S
    Ken-Dror, G
    Avni, I
    Zadok, D
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) : 1729 - 1735
  • [10] Comparison of manual and automated methods to determine horizontal corneal diameter
    Baumeister, M
    Terzi, E
    Ekici, Y
    Kohnen, T
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (02) : 374 - 380