Rapid method for qualitative detection of 2,4,6-trinitrotoluene in environmental water samples

被引:8
作者
Basova, Evgenia Yu. [1 ]
Goryacheva, Irina Yu. [1 ]
Mikhirev, Dmitry A. [1 ]
Rusanova, Tatiana Yu. [1 ]
Burmistrova, Natalia A. [1 ]
Kerkaert, Barbara [2 ]
Cucu, Tania [2 ]
De Saeger, Sarah [3 ]
De Meulenaer, Bruno [2 ]
机构
[1] Saratov NG Chernyshevskii State Univ, Inst Chem, Dept Common & Inorgan Chem, Saratov 410012, Russia
[2] Univ Ghent, Dept Food Safety & Food Qual, Fac Biosci, Res Grp Food Chem & Human Nutr, B-9000 Ghent, Belgium
[3] Univ Ghent, Lab Food Anal, Dept Bioanal, Fac Pharmaceut Sci, B-9000 Ghent, Belgium
关键词
SURFACE-PLASMON RESONANCE; TNT DETECTION; OCHRATOXIN-A; NONINSTRUMENTAL DETECTION; DISPLACEMENT IMMUNOASSAY; ENZYME-IMMUNOASSAY; TRACE DETECTION; IMMUNOSENSOR; EXPLOSIVES; BIOSENSOR;
D O I
10.1039/b9ay00144a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A gel-based immunoassay that can be used for the detection of 2,4,6-trinitrotoluene (TNT) in water samples was developed. Four polyclonal antibodies were generated in chickens using TNT derivatives. The assay was based on the immunoaffinity preconcentration and immuno-enzyme analysis of TNT in the gel. The results of the assay, assessed by color development, were evaluated visually and also by using a flatbed scanner and subsequent digital processing of the scanned gel. The most sensitive color mode, parameter S (saturation, HSB mode), was used for the immunoassay optimization and evaluation of the results. The immunoassays with the best parameters were optimized and characterized. A cut-off level of 5 mu g TNT L-1 was reached for water samples. It was shown that tap and environmental water samples could be analyzed directly, without sample preparation and dilution. The developed test is acceptable for use in an on-site field test to provide rapid (about 15 min for six samples), qualitative and reliable results for making environmental decisions such as identifying "hot spots", monitoring of military and terrorist activities, and selecting of site samples for laboratory analysis.
引用
收藏
页码:170 / 176
页数:7
相关论文
共 26 条
  • [1] Surface plasmon resonance-based trace detection of small molecules by competitive and signal enhancement immunoreaction
    Aizawa, Hidenobu
    Tozuka, Mitsuhiro
    Kurosawa, Shigeru
    Kobayashi, Koichi
    Reddy, Subrayal M.
    Higuchi, Masahiro
    [J]. ANALYTICA CHIMICA ACTA, 2007, 591 (02) : 191 - 194
  • [2] IMMUNOGLOBULINS FROM EGG-YOLK - ISOLATION AND PURIFICATION
    AKITA, EM
    NAKAI, S
    [J]. JOURNAL OF FOOD SCIENCE, 1992, 57 (03) : 629 - 634
  • [3] TNT detection using multiplexed liquid array displacement immunoassays
    Anderson, GP
    Moreira, SC
    Charles, PT
    Medintz, IL
    Goldman, ER
    Zeinali, M
    Taitt, CR
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (07) : 2279 - 2285
  • [4] Validation of an antibody-based biosensor for rapid quantification of 2,4,6-trinitrotoluene (TNT) contamination in ground water and river water
    Bromage, Erin S.
    Vadas, George G.
    Harvey, Ellen
    Unger, Michael A.
    Kaattari, Stephen L.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (20) : 7067 - 7072
  • [5] Development of an enzyme-linked immunosorbent assay for bisphenol A using chicken immunoglobulins
    De Meulenaer, B
    Baert, K
    Lanckriet, H
    Van Hoed, V
    Huyghebaert, A
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (19) : 5273 - 5282
  • [6] Analysis of aqueous 2,4,6-trinitrotoluene (TNT) using a fluorescent displacement immunoassay
    Goldman, ER
    Anderson, GP
    Lebedev, N
    Lingerfelt, BM
    Winter, PT
    Patterson, CH
    Mauro, JM
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (04) : 471 - 475
  • [7] Novel gel-based rapid test for non-instrumental detection of ochratoxin A in beer
    Goryacheva, I. Y.
    Basova, E. Y.
    Van Peteghem, C.
    Eremin, S. A.
    Pussemier, L.
    Motte, J. -C.
    De Saeger, S.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (02) : 723 - 727
  • [8] Approach for ochratoxin A fast screening in spices using clean-up tandem immunoassay columns with confirmation by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS)
    Goryacheva, I. Yu.
    De Saeger, S.
    Lobeau, M.
    Eremin, S. A.
    Barna-Vetro, I.
    Van Peteghem, C.
    [J]. ANALYTICA CHIMICA ACTA, 2006, 577 (01) : 38 - 45
  • [9] Gel-based immunoassay for non-instrumental detection of pyrene in water samples
    Goryacheva, Irina Yu.
    Beloglazova, Natalia V.
    Eremin, Sergei A.
    Mikhirev, Dmitry A.
    Niessner, Reinhard
    Knopp, Dietmar
    [J]. TALANTA, 2008, 75 (02) : 517 - 522
  • [10] Fabrication of a novel immunosensor using functionalized self-assembled monolayer for trace level detection of TNT by surface plasmon resonance
    Kawaguchi, Toshikazu
    Shankaran, Dhesingh Ravi
    Kim, S. J.
    Gobi, K. Vengatajalabathy
    Matsumoto, Kiyoshi
    Toko, Kiyoshi
    Miura, Norio
    [J]. TALANTA, 2007, 72 (02) : 554 - 560