Innovative seismic resistant structure of shield building with base isolation and tuned-mass-damping for AP1000 nuclear power plants

被引:9
作者
Hou, Gangling [1 ]
Li, Meng [1 ]
Hai, Sun [1 ]
Song, Tianshu [1 ]
Wu, Lingshu [1 ]
Li, Yong [2 ]
Zheng, Gang [3 ]
Shen, Feng [3 ]
Chen, Yaodong [3 ]
机构
[1] Harbin Engn Univ, Coll Aerosp & Civil Engn, Harbin, Heilongjiang, Peoples R China
[2] Univ Alberta, Dept Civil & Environm Engn, Edmonton, AB, Canada
[3] State Power Investment Corp Cent Res Inst, Beijing, Peoples R China
关键词
Nuclear power plants; Base isolation; Passive Safety concept; Seismic response modification; Tuned mass damping; DAMPER;
D O I
10.1108/EC-10-2018-0483
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Purpose Seismic isolation, as an effective risk mitigation strategy of building/bridge structures, is incorporated into AP1000 nuclear power plants (NPPs) to alleviate the seismic damage that may occur to traditional structures of NPPs during their service. This is to promote the passive safety concept in the structural design of AP1000 NPPs against earthquakes. Design/methodology/approach In conjunction with seismic isolation, tuned-mass-damping (TMD) is integrated into the seismic resistance system of AP1000 NPPs to satisfy the multi-functional purposes. The proposed base-isolation-tuned-mass-damper (BIS-TMD) is studied by comparing the seismic performance of NPPs with four different design configurations (i.e. without BIS, BIS, BIS-TMD and TMD) with the design parameters of the TMD subsystem optimized. Findings Such a new seismic protection system (BIS-TMD) is proved to be promising because the advantages of BIS and TMD can be fully used. The benefits of the new structure include effective energy dissipation (i.e. wide vibration absorption band and a stable damping effect), which results in the high performance of NPPs subject to earthquakes with various intensity levels and spectra features. Originality/value Parametric studies are performed to demonstrate the seismic robustness (e.g. consistent performance against the changing mass of the water in the gravity liquid tank and mechanical properties) which further ensures that seismic safety requirements of NPPs can be satisfied through the use of BIS-TMD.
引用
收藏
页码:1238 / 1257
页数:20
相关论文
共 27 条
[1]   PROBABILISTIC SEISMIC ASSESSMENT OF BASE-ISOLATED NPPS SUBJECTED TO STRONG GROUND MOTIONS OF TOHOKU EARTHQUAKE [J].
Ali, Ahmer ;
Abu Hayah, Nadin ;
Kim, Dookie ;
Cho, Sung Gook .
NUCLEAR ENGINEERING AND TECHNOLOGY, 2014, 46 (05) :699-706
[2]  
American Society of Civil Engineers, 1999, SEISM AN SAF REL NUC, P4
[3]  
Architectural Society of Japan, 2006, DES SEISM IS STRUCT
[4]   Optimal design of base-isolators in multi-storey buildings [J].
Baratta, A ;
Corbi, I .
COMPUTERS & STRUCTURES, 2004, 82 (23-26) :2199-2209
[5]   Seismic analysis and evaluation of the base isolation system in AP1000 NI under SSE loading [J].
Chen, Jianyun ;
Zhao, Chunfeng ;
Xu, Qiang ;
Yuan, Chenyang .
NUCLEAR ENGINEERING AND DESIGN, 2014, 278 :117-133
[6]  
De Silva C.W., 2007, Vibration damping, control, and design
[7]  
Forni M, 2012, WORLD C EARTHAQUAKE, V63, P636
[8]  
Forni M., 2010, GUIDELINES PROPOSAL
[9]  
Forni M, 2010, ASME PRESSURE VESSELS AND PIPING CONFERENCE, VOL 8: SEISMIC ENGINEERING, P289
[10]   VIBRATION STUDIES AND TESTS OF LIQUID STORAGE TANKS [J].
HAROUN, MA .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1983, 11 (02) :179-206