Liposome-coated metal stents:: An in vitro evaluation of controlled-release modality in the ureter

被引:24
作者
Antimisiaris, SG
Siablis, D
Liatsikos, E
Kalogeropoulou, C
Tsota, I
Tsotas, V
Karnabatidis, D
Fatouros, DG
Barbalias, GA [1 ]
机构
[1] Univ Patras, Univ Hosp, Sch Med, Dept Urol, Patras 26500, Greece
[2] Univ Patras, Sch Med, Dept Radiol, GR-26110 Patras, Greece
[3] Univ Patras, Sch Med, Dept Pharm, Pharmaceut Technol Lab, GR-26110 Patras, Greece
关键词
D O I
10.1089/end.2000.14.743
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: In vitro preparation of liposome-covered metal stents and loading of liposomal drug formulations that will slowly release the drug in the vicinity of the stent. Materials and Methods: Polytetrafluoroethylene-coated stents were used. Large multilamellar (MLV) liposomes (phosphatidylcholine:cholesterol 1:1 mol/mol), empty or entrapping the corticosteroid anti-inflammatory drug, dexamethasone, were prepared by the thin-film hydration method and applied to pieces of stent using a simple and mild evaporation technique. Initially, a freeze-drying method for applying liposomes to stents was also evaluated, but it failed to produce stents that efficiently retain liposomal lipid when incubated in an aqueous environment, The presence of liposomes on the stent surface was confirmed by scanning electron microscopy. Results: After analyzing the release of liposomal lipid (using a phospholipid assay) and liposomal drug (by a modified dexamethasone high-pressure liquid chromatography method) in an in vitro system developed to simulate in vivo conditions, it was found that 39.11 +/- 6.8% of the lipid and 50.84 +/- 5.48% of the drug was released from the stent pieces during 48 hours of incubation in the presence of artificial urine. The amount of dexamethasone released from stents during their application procedure was found to be negligible in an in vitro dry run. Conclusion: The use of stent-associated liposomal drug formulations as slow-release depots could be an efficient method of treating the untoward event of ureteral stent obstruction.
引用
收藏
页码:743 / 747
页数:5
相关论文
共 18 条
  • [1] Ureteroileal anastomotic strictures: An innovative approach with metallic stents
    Barbalias, GA
    Liatsikos, EN
    Karnabatidis, D
    Yarmenitis, S
    Siablis, D
    [J]. JOURNAL OF UROLOGY, 1998, 160 (04) : 1270 - 1273
  • [2] Metal stents: A new treatment of malignant ureteral obstruction
    Barbalias, GA
    Siablis, D
    Liatsikos, EN
    Karnabatidis, D
    Yarmenitis, S
    Bouropoulos, K
    Dimopoulos, J
    [J]. JOURNAL OF UROLOGY, 1997, 158 (01) : 54 - 58
  • [3] CLELAND M, 1981, BIOCHIM BIOPHYS ACTA, V597, P418
  • [4] NITINOL INTRAVASCULAR STENT - RESULTS OF PRECLINICAL EVALUATION
    CRAGG, AH
    DEJONG, SC
    BARNHART, WH
    LANDAS, SK
    SMITH, TP
    [J]. RADIOLOGY, 1993, 189 (03) : 775 - 778
  • [5] A liposomal hydrogel for the prevention of bacterial adhesion to catheters
    DiTizio, V
    Ferguson, GW
    Mittelman, MW
    Khoury, AE
    Bruce, AW
    DiCosmo, F
    [J]. BIOMATERIALS, 1998, 19 (20) : 1877 - 1884
  • [6] MALIGNANT URETERAL OBSTRUCTION - PRELIMINARY-RESULTS OF TREATMENT WITH METALLIC SELF-EXPANDABLE STENTS
    FLUECKIGER, F
    LAMMER, J
    KLEIN, GE
    HAUSEGGER, K
    LEDERER, A
    SZOLAR, D
    TAMUSSINO, K
    [J]. RADIOLOGY, 1993, 186 (01) : 169 - 173
  • [7] Engineering liposomes for drug delivery: Progress and problems
    Gregoriadis, G
    [J]. TRENDS IN BIOTECHNOLOGY, 1995, 13 (12) : 527 - 537
  • [8] GREGORIADIS G, 1988, LIPSOMES DRUG CARRIE
  • [9] DEHYDRATION-REHYDRATION VESICLES - A SIMPLE METHOD FOR HIGH-YIELD DRUG ENTRAPMENT IN LIPOSOMES
    KIRBY, C
    GREGORIADIS, G
    [J]. BIO-TECHNOLOGY, 1984, 2 (11): : 979 - 984
  • [10] BENIGN PROSTATIC HYPERTROPHY - TREATMENT WITH A METALLIC STENT
    MACHAN, L
    JAGER, HR
    ADAM, A
    GILL, K
    WILLIAMS, G
    ALLISON, DJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (04) : 779 - 781