Quantitative analysis of misplaced pedicle screws in the thoracic spine: how much pullout strength is lost? Presented at the 2009 Joint Spine Section Meeting Laboratory investigation

被引:38
作者
Brasiliense, Leonardo B. C. [1 ]
Theodore, Nicholas [1 ]
Lazaro, Bruno C. R. [1 ]
Sayed, Zafar A. [1 ]
Deniz, Fatih Ersay [1 ]
Sonntag, Volker K. H. [1 ]
Crawford, Neil R. [1 ]
机构
[1] St Josephs Hosp, Barrow Neurol Inst, Div Neurol Surg, Phoenix, AZ 85013 USA
关键词
misplacement; pedicle screw; thoracic spine; pullout strength; cadaver; BIOMECHANICAL ANALYSIS; FIXATION; PLACEMENT; INSTRUMENTATION; ACCURACY; LUMBAR; AUGMENTATION; ARCHITECTURE; CORTEX;
D O I
10.3171/2009.11.SPINE09408
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. The object of this study was to investigate the effects of iatrogenic pedicle perforations from screw misplacement on the mean pullout strength of thoracic pedicle screws. Methods. Forty human thoracic vertebrae (T6-11) from human cadavers were studied. Before pedicle screws were inserted, the specimens were separated into 4 groups according to the type of screw used: 1) standard pedicle screw (no cortical perforation); 2) screw with medial cortical perforation; 3) screw with lateral cortical perforation: and 4) "airball" screw (a screw that completely missed the vertebral body). Consistency among the groups for bone mineral density, pedicle diameter, and screw insertion depth was evaluated. Finally. each screw was pulled out at a constant displacement rate of 10 mm/minute while ultimate strength was recorded. Results. Compared with well-placed pedicle screws, medially misplaced screws had 8% greater mean pullout strength (p = 0.482) and laterally misplaced screws had 21% less mean pullout strength (p = 0.059). The difference in mean pullout strength between screws with medial and lateral cortical perforations was significant (p = 0.013). Airball screws had only 66% of the mean pullout strength of well-placed screws (p = 0.009) and had 16% lower mean pullout strength than laterally misplaced screws (p = 0.395). Conclusions. This in vitro study showed a significant difference in mean pullout strength between medial and lateral misplaced pedicle screws. Moreover, airball screws were associated with a significant loss of pullout strength. (DOI: 10.3171/2009.11.SPINE09408)
引用
收藏
页码:503 / 508
页数:6
相关论文
共 30 条
[1]   Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine [J].
Amiot, LP ;
Lang, K ;
Putzier, M ;
Zippel, H ;
Labelle, H .
SPINE, 2000, 25 (05) :606-614
[2]   In vivo accuracy of thoracic pedicle screws [J].
Belmont, PJ ;
Klemme, WR ;
Dhawan, A ;
Polly, DW .
SPINE, 2001, 26 (21) :2340-2346
[3]   THE EFFECTS OF PEDICLE SCREW FIT - AN IN-VITRO STUDY [J].
BRANTLEY, AGU ;
MAYFIELD, JK ;
KOENEMAN, JB ;
CLARK, KR .
SPINE, 1994, 19 (15) :1752-1758
[4]   Primary pedicle screw augmentation in osteoporotic lumbar vertebrae - Biomechanical analysis of pedicle fixation strength [J].
Burval, Daniel J. ;
McLain, Robert F. ;
Milks, Ryan ;
Inceoglu, Serkan .
SPINE, 2007, 32 (10) :1077-1083
[5]   Pedicle instrumentation in the thoracic spine - A morphometric and cadaveric study for placement of screws [J].
Cinotti, G ;
Gumina, S ;
Ripani, M ;
Postacchini, F .
SPINE, 1999, 24 (02) :114-119
[6]   AN ANATOMIC, RADIOGRAPHIC, AND BIOMECHANICAL ASSESSMENT OF EXTRAPEDICULAR SCREW FIXATION IN THE THORACIC SPINE [J].
DVORAK, M ;
MACDONALD, S ;
GURR, KR ;
BAILEY, SI ;
HADDAD, RG .
SPINE, 1993, 18 (12) :1689-1694
[7]  
Edwards WT, 2001, SPINE, V26, P218
[8]   COMPLICATIONS ASSOCIATED WITH THE TECHNIQUE OF PEDICLE SCREW FIXATION - A SELECTED SURVEY OF ABS MEMBERS [J].
ESSES, SI ;
SACHS, BL ;
DREYZIN, V .
SPINE, 1993, 18 (15) :2231-2239
[9]  
GEORGE DC, 1991, SPINE, V16, P181, DOI 10.1097/00007632-199116020-00015
[10]   ACCURACY OF PEDICULAR SCREW PLACEMENT INVIVO [J].
GERTZBEIN, SD ;
ROBBINS, SE .
SPINE, 1990, 15 (01) :11-14