Clinical outcomes with a low add multifocal and an extended depth of focus intraocular lenses both implanted with mini-monovision

被引:12
|
作者
Sevik, Mehmet Orkun [1 ]
Turhan, Semra Akkaya [1 ]
Toker, Ebru [1 ]
机构
[1] Marmara Univ, Dept Ophthalmol, Sch Med, Istanbul, Turkey
关键词
BILATERAL IMPLANTATION; VISUAL OUTCOMES; CONTRAST SENSITIVITY; NORMAL VALUES; RANGE; VISION; PERFORMANCE; QUALITY; ACUITY;
D O I
10.1038/s41433-021-01600-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives To compare the visual acuity, contrast sensitivity (CS), spectacle needs, photic phenomena, and quality of life parameters of patients bilaterally implanted with a low add multifocal (MIOL) or an extended depth of focus (EDOF) intraocular lens (IOL), both with intended mini-monovision. Methods In this prospective, randomized, comparative study, patients were randomized to receive either Tecnis +2.75 D (ZKB00) (MIOL Group, n = 15) or Tecnis Symfony (ZXR00) (EDOF Group, n = 14) for bilateral implantation with mini-monovision (-0.50 D). Binocular logMAR uncorrected visual acuities (UVA), monocular defocus curves, CS with CSV 1000-E, and Pelli-Robson Test (PRT), spectacle needs and quality of life parameters with NEI RQL-42 questionnaire were evaluated at postoperative 1, 3, and 6 months. Results Results of MIOL and EDOF Groups at postoperative month 6 are as follows: distance (6 m) UVA -0.03 +/- 0.05 and -0.05 +/- 0.06 (p = 0.938), intermediate (60 cm) UVA, 0.04 +/- 0.08 and -0.03 +/- 0.07 (p = 0.046); near (40 cm) UVA, 0.22 +/- 0.08 and 0.15 +/- 0.07 (p = 0.046); near spectacle needs, 26.7% and 14.3% (p > 0.05), respectively. Better visual acuity was achieved in the EDOF Group between the defocus range of -0.50 and -1.75 D (p < 0.05). No significant difference was found regarding photic phenomena and CS evaluated with CSV 1000-E between the two IOL groups at 6 months after surgery (otherwise there are differences at 1 and 3 months in favor of EDOF). However, EDOF Group performed better in mesopic CS evaluated with PRT (p < 0.05). Conclusions When implanted with mini-monovision better binocular uncorrected visual performance at intermediate and near distances achieved with EDOF than low add MIOL.
引用
收藏
页码:1168 / 1177
页数:10
相关论文
共 50 条
  • [41] Six-Month Clinical Outcomes with Bilateral Mix-and-match Implantation of Extended Depth of Focus and Trifocal Intraocular Lenses
    Kim, Jae Yong
    An, Hye Rin
    Nam, Sanghyu
    Lee, Ko Eun
    Lee, Hun
    Tchah, Hungwon
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [42] Effect of crystalline lens decentration and tilt on visual performance in eyes implanted with bifocal or extended depth of focus intraocular lenses
    Zhang, Yu
    Zhang, Jiaqing
    Liang, Chen
    Xu, Yifan
    Wu, Jiaying
    Wu, Junming
    Zhang, Yifan
    Jin, Aixia
    Tan, Xuhua
    Luo, Lixia
    BMC OPHTHALMOLOGY, 2025, 25 (01)
  • [43] Clinical outcomes in eyes with diffractive continuous depth-of-focus intraocular lenses enhanced for near vision: comparison with trifocal intraocular lenses
    Nomura, Yuya
    Ota, Yuka
    Fujita, Yoshifumi
    Nishimura, Tomohisa
    Bissen-Miyajima, Hiroko
    Minami, Keiichiro
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [44] Clinical outcomes in eyes with diffractive continuous depth-of-focus intraocular lenses enhanced for near vision: comparison with trifocal intraocular lenses
    Yuya Nomura
    Yuka Ota
    Yoshifumi Fujita
    Tomohisa Nishimura
    Hiroko Bissen-Miyajima
    Keiichiro Minami
    BMC Ophthalmology, 23
  • [45] Visual outcomes and higher-order aberrations in eyes implanted with hybrid extended depth of focus intraocular lens
    Kenia, Vaishal P.
    Kenia, Raj V.
    Mudaliya, Laxmi
    Pirdankar, Onkar H.
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2023, 13 (03) : 341 - 345
  • [46] Visual Performance and Patient Satisfaction of Bilaterally Implanted Extended Depth of Focus Intraocular Lens: Outcomes of a Multicenter Registry
    Howes, Frank
    Rementeria-Capelo, Laureano A.
    Poyales, Francisco
    Borovik, Armand
    Khoramnia, Ramin
    Perez-Vives, Caridad
    Nuijts, Rudy M. M. A.
    JOURNAL OF REFRACTIVE SURGERY, 2025, 41 (02)
  • [47] Non-diffractive, toric, extended depth-of-focus intraocular lenses in eyes with low corneal astigmatism
    Pastor-Pascual, Francisco
    Orts-Vila, Paz
    Tana-Sanz, Pedro
    Tana-Sanz, Santiago
    Ruiz-Mesa, Ramon
    Tana-Rivero, Pedro
    EYE AND VISION, 2024, 11 (01)
  • [48] Non-diffractive, toric, extended depth-of-focus intraocular lenses in eyes with low corneal astigmatism
    Francisco Pastor-Pascual
    Paz Orts-Vila
    Pedro Tañá-Sanz
    Santiago Tañá-Sanz
    Ramón Ruiz-Mesa
    Pedro Tañá-Rivero
    Eye and Vision, 11
  • [49] Multifocal and Extended Depth of Focus Intraocular Lenses: A Comparison of Data from the United States Food and Drug Administration Premarket Approval Trials
    Schallhorn, Julie M.
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (02) : 98 - +
  • [50] Prospective Comparison of Clinical Outcomes After Bilateral Implantation of Diffractive Trifocal Extended Depth-of-Focus and Diffractive Trifocal Hydrophobic Intraocular Lenses
    Nagy, Zoltan Z.
    Dorman, Peter
    Szalczer, Szilard
    Kiss, Huba
    JOURNAL OF REFRACTIVE SURGERY, 2025, 41 (02)