A Novel Whole Spectrum-Based Non-Invasive Screening Device for Neonatal Hyperbilirubinemia

被引:17
作者
Halder, Animesh [1 ,2 ]
Banerjee, Mukut [4 ]
Singh, Soumendra [3 ]
Adhikari, Aniruddha [3 ]
Sarkar, Probir Kumar [3 ]
Bhattacharya, Arnab Madhab [4 ]
Chakrabarti, Prantar [5 ]
Bhattacharyya, Debasis [4 ]
Mallick, Asim Kumar [4 ]
Pal, Samir Kumar [1 ,3 ]
机构
[1] SN Bose Natl Ctr Basic Sci, Tech Res Ctr, Kolkata 700106, India
[2] Univ Calcutta, Dept Appl Opt & Photon, Kolkata 700106, India
[3] SN Bose Natl Ctr Basic Sci, Dept Chem Biol & Macromol Sci, Kolkata 700106, India
[4] Nil Ratan Sircar Med Coll & Hosp, Dept Pediat Med, Kolkata 700014, India
[5] Nil Ratan Sirkar Med Coll & Hosp, Dept Haematol, Kolkata 700014, India
关键词
Pediatrics; Nails; Probes; Blood; Biomedical measurement; Software; Neonatal jaundice; diffuse reflection; non-invasive optical method; whole spectrum-based diagnosis; LabVIEW; CALCULATING CORRELATION-COEFFICIENTS; STATISTICS NOTES; BILIRUBIN; AGREEMENT; DIAGNOSIS; NEWBORN; SERUM;
D O I
10.1109/JBHI.2019.2892946
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Objective: Careful screening of bilirubin level in newborns is mandatory as per American Academy of Pediatrics (2004), to reduce incidents of kernicterus and acute bilirubin encephalopathy. Although, invasive capillary collection of blood and subsequent biochemical test is considered a gold standard for jaundice detection in neonates, transcutaneous bilirubin measurement using various non-invasive instruments is also used sporadically across the globe. The major aim of this study was to develop a non-invasive spectrometry-based technique for measurement of neonatal bilirubin level as an alternative of total serum bilirubin (TSB) test without limitations of other available bilirubinometers. Methods: The instrument comprises of a light source and a spectroscopic detector. A light beam from source incident on the neonatal nail plate through optical fibers. The retro reflected light is acquired using the detector. An indigenously developed software is used to acquire and analyze the optical signal and to calculate the bilirubin value. The instrument was calibrated and validated in reference to TSB on 1033 subjects. Major results: The result (r 0.95 and P < 0.001) indicates a strong correlation between the bilirubin value obtained from our method and TSB. Time variant analysis of the subjects undergoing phototherapy provided a good correlation (r 0.98). The repeatability test result shows the mean coefficient of variation is less than 5.0. Conclusions: The indigenously developed non-invasive technique successfully detects the bilirubin level in newborns under various physiological conditions with high accuracy and precision.
引用
收藏
页码:2347 / 2353
页数:7
相关论文
共 32 条
[1]  
Abdullah L, 2011, CAN FAM PHYSICIAN, V57, P173
[2]   High-dose intravenous immunoglobulin therapy in neonatal immune haemolytic jaundice [J].
Alpay, F ;
Sarici, SÜ ;
Okutan, V ;
Erdem, G ;
Özcan, O ;
Gökçay, E .
ACTA PAEDIATRICA, 1999, 88 (02) :216-219
[3]   Universal bilirubin screening for severe neonatal hyperbilirubinemia [J].
Bhutani, V. K. ;
Vilms, R. J. ;
Hamerman-Johnson, L. .
JOURNAL OF PERINATOLOGY, 2010, 30 :S6-S15
[4]   Neonatal hyperbilirubinemia and Rhesus disease of the newborn: incidence and impairment estimates for 2010 at regional and global levels [J].
Bhutani, Vinod K. ;
Zipursky, Alvin ;
Blencowe, Hannah ;
Khanna, Rajesh ;
Sgro, Michael ;
Ebbesen, Finn ;
Bell, Jennifer ;
Mori, Rintaro ;
Slusher, Tina M. ;
Fahmy, Nahed ;
Paul, Vinod K. ;
Du, Lizhong ;
Okolo, Angela A. ;
de Almeida, Maria-Fernanda ;
Olusanya, Bolajoko O. ;
Kumar, Praveen ;
Cousens, Simon ;
Lawn, Joy E. .
PEDIATRIC RESEARCH, 2013, 74 :86-100
[5]   STATISTICS NOTES .1. CORRELATION, REGRESSION, AND REPEATED DATA [J].
BLAND, JM ;
ALTMAN, DG .
BRITISH MEDICAL JOURNAL, 1994, 308 (6933) :896-896
[6]   STATISTICS NOTES .12. CALCULATING CORRELATION-COEFFICIENTS WITH REPEATED OBSERVATIONS .1. CORRELATION WITHIN-SUBJECTS [J].
BLAND, JM ;
ALTMAN, DG .
BRITISH MEDICAL JOURNAL, 1995, 310 (6977) :446-446
[7]   CALCULATING CORRELATION-COEFFICIENTS WITH REPEATED OBSERVATIONS .2. CORRELATION BETWEEN SUBJECTS [J].
BLAND, JM ;
ALTMAN, DG .
BRITISH MEDICAL JOURNAL, 1995, 310 (6980) :633-633
[8]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[9]   Limitations and Opportunities of Transcutaneous Bilirubin Measurements [J].
Bosschaart, Nienke ;
Kok, Joke H. ;
Newsum, Astrid M. ;
Ouweneel, Dagmar M. ;
Mentink, Rosaline ;
van Leeuwen, Ton G. ;
Aalders, Maurice C. G. .
PEDIATRICS, 2012, 129 (04) :689-694
[10]   CLINICAL PHARMACOKINETICS OF CLOFIBRATE IN THE JAUNDICED NEONATE AT TERM [J].
BOURGET, P ;
BROISE, I ;
QUINQUISDESMARIS, V ;
GABILAN, JC .
ARCHIVES DE PEDIATRIE, 1995, 2 (08) :722-728