Detection of T-Wave Beat-By-Beat Variations prior to Ventricular Arrhythmias Onset in ICD-Stored Intracardiac Electrograms: The Endocardial T-Wave Alternans Study (ETWAS)

被引:5
|
作者
Maury, Philippe [1 ]
Lin, Chao [2 ]
Pasquie, Jean-Luc [3 ]
Raczka, Frank [3 ]
Beck, Lionel [4 ]
Taieb, Jerome [5 ]
Mailhes, Corinne [2 ]
Tourneret, Jean-yves [2 ]
Rollin, Anne [1 ]
Duparc, Alexandre [1 ]
Mondoly, Pierre [1 ]
Winum, Pierre [4 ]
Rolland, Philippe [6 ]
Castanie, Francis [2 ]
Hallier, Benoit [6 ]
机构
[1] Univ Hosp Rangueil, F-31059 Toulouse 09, France
[2] Lab TeSA, Toulouse, France
[3] Univ Hosp Arnaud de Villeneuve, Montpellier, France
[4] Univ Hosp Carremeau, Nimes, France
[5] Gen Hosp Pays Aix, Aix En Provence, France
[6] EMEAC, Zaventem, Belgium
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2014年 / 37卷 / 11期
关键词
T-wave alternans; sudden death; implantable cardioverter defibrillator; intracardiac electrogram; ventricular tachycardia; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; SUDDEN CARDIAC DEATH; REPOLARIZATION ALTERNANS; GIBBS SAMPLER; HEART-RATE; FIBRILLATION; PREDICTOR; HUMANS; MODEL; TACHYARRHYTHMIAS;
D O I
10.1111/pace.12453
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe aim of the Endocardial T-Wave Alternans Study was to prospectively assess the presence of T-wave alternans (TWA) or beat-to-beat repolarization changes on implantable cardioverter-defibrillator (ICD)-stored electrograms (EGMs) immediately preceding the onset of spontaneous ventricular tachycardia (VT) or fibrillation (VF). MethodsThirty-seven VT/VF episodes were compared to 116 baseline reference EGMs from the same 57 patients. A Bayesian model was used to estimate the T-wave waveform in each cardiac beat and a set of 10 parameters was selected to segment each detected T wave. Beat-by-beat differences in each T-wave parameter were computed using the absolute value of the difference between each beat and the following one. Fisher criterion was used for determining the most discriminant T-wave parameters, then top-M ranked parameters yielding a normalized cumulative Fisher score > 95% were selected, and analysis was applied on these selected parameters. Simulated TWA EGMs were used to validate the algorithm. ResultsIn the simulation study, TWA was detectable even in the case of the smallest simulated alternans of 25 V. In 13 of the 37 episodes (35%) occurring in nine of 16 patients, significant larger beat-to-beat variations before arrhythmia onset were detected compared to their respective references (median one positive episode per patient). Parameters including the T-wave apex amplitude seem the more discriminant parameters. ConclusionsDetection of beat-by-beat repolarization variations in ICD-stored EGMs is feasible in a significant subset of cases and may be used for predicting the onset of ventricular arrhythmias.
引用
收藏
页码:1510 / 1519
页数:10
相关论文
共 50 条
  • [41] Beat-to-beat T-wave amplitude variability in the risk stratification of right ventricular outflow tract-premature ventricular complex patients
    Ichikawa, Tomohide
    Sobue, Yoshihiro
    Kasai, Atsunobu
    Kiyono, Ken
    Hayano, Junichiro
    Yamamoto, Mayumi
    Okuda, Kentarou
    Watanabe, Eiichi
    Ozaki, Yukio
    EUROPACE, 2016, 18 (01): : 138 - 145
  • [42] Rate-related variations in T-wave alternans affect in sensitivity and specificity for inducible ventricular tachycardia
    Narayan, SM
    Botteron, GW
    Smith, JM
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 483A - 483A
  • [43] Microvolt QRS Alternans Without Microvolt T-Wave Alternans in Human Cardiomyopathy: A Novel Risk Marker of Late Ventricular Arrhythmias
    Suszko, Adrian
    Nayyar, Sachin
    Labos, Christopher
    Nanthakumar, Kumaraswamy
    Pinter, Arnold
    Crystal, Eugene
    Chauhan, Vijay S.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2020, 9 (17):
  • [44] Mechanisms linking T-wave alternans to spontaneous initiation of ventricular arrhythmias in rabbit models of long QT syndrome
    Liu, Weiqing
    Kim, Tae Yun
    Huang, Xiaodong
    Liu, Michael B.
    Koren, Gideon
    Choi, Bum-Rak
    Qu, Zhilin
    JOURNAL OF PHYSIOLOGY-LONDON, 2018, 596 (08): : 1341 - 1355
  • [45] The Power of Exercise-Induced T-wave Alternans to Predict Ventricular Arrhythmias in Patients with Implanted Cardiac Defibrillator
    Burattini, Laura
    Man, Sumche
    Sweene, Cees A.
    JOURNAL OF HEALTHCARE ENGINEERING, 2013, 4 (02) : 167 - 183
  • [46] T-wave alternans and dispersion of the QT interval as risk stratification markers in patients susceptible to sustained ventricular arrhythmias
    Armoundas, AA
    Osaka, M
    Mela, T
    Rosenbaum, DS
    Ruskin, JN
    Garan, H
    Cohen, RJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (09): : 1127 - +
  • [47] T-wave alternans poorly prognostic in primary prophylactic ICD patients: a prospective EU-CERT-ICD study
    Pelli, A.
    Junttila, M. J.
    Kentta, T. V.
    Schlogl, S.
    Zabel, M.
    Malik, M.
    Reichlin, T.
    Willems, R.
    Vos, M. A.
    Harden, M.
    Friede, T.
    Sticherling, C.
    Huikuri, H.
    EUROPEAN HEART JOURNAL, 2022, 43 : 491 - 491
  • [48] Microvolt T-wave alternans as a predictor of ventricular tachyarrhythmias - A prospective study using atrial pacing
    Tanno, KR
    Ryu, S
    Watanabe, N
    Minoura, Y
    Kawamura, M
    Asano, T
    Kobayashi, Y
    Katagiri, T
    CIRCULATION, 2004, 109 (15) : 1854 - 1858
  • [49] Microvolt T-wave alternans as a predictor of ventricular tachyarrhythmias: A prospective study using atrial pacing
    Tanno, K
    Watanabe, N
    Ryu, S
    Minoura, Y
    Kawamura, M
    Asano, T
    Kobayashi, Y
    Katagiri, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 141A - 141A
  • [50] Dependency of Exercise-Induced T-Wave Alternans Predictive Power for the Occurrence of Ventricular Arrhythmias from Heart Rate
    Burattini, Laura
    Man, Sumche
    Fioretti, Sandro
    Di Nardo, Francesco
    Swenne, Cees A.
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2015, 20 (04) : 345 - 354