EVALUATION OF NATURAL WORKING FLUIDS FOR THE DEVELOPMENT OF HIGH TEMPERATURE HEAT PUMPS

被引:15
作者
Bamigbetan, Opeyemi [1 ]
Eikevik, Trygve [1 ]
Neksa, Petter [2 ]
Bantle, Michael [2 ]
机构
[1] Norwegian Univ Sci & Technol, Kolbjorn Hejes Vei 1D, N-7049 Trondheim, Norway
[2] SINTEF Energy Res, Kolbjorn Hejes Vei 1D, N-7465 Trondheim, Norway
来源
12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE | 2016年
关键词
Natural working fluids; High temperature; Heat pump; Mixtures; Refrigerant selection; RECOVERY; SYSTEM; PERFORMANCE;
D O I
10.18462/iir.gl.2016.1092
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
For a sustainable future in energy, the use of natural fluids in heat pump systems can provide an efficient solution to combat the ozone depletion and the global warming effects of synthetic working fluids. These natural fluids, though environmentally friendly, must be able to operate at high temperature in heat pumps in an efficient and cost effective way to be viable for the industry heat demand. High temperature heat pumps with heat source and heat sink temperatures ranging from 40 degrees C to 200 degrees C have unique challenges with natural working fluids. This paper evaluates the performance and use of natural working fluids for high temperature heat pumps. The analysis is based on simple thermodynamic cycles. A simulation tool coupled with a thermodynamic properties database is used to evaluate the operating limitations of the natural fluids. Natural fluids such as ammonia, hydrocarbon and hydrocarbon mixtures are considered. The hydrocarbon mixtures, benefitting from both adjusted thermodynamic properties and a higher evaporating temperature due to better fit to heat source temperature, shows greatest potential for the development of high temperature heat pumps. The mixtures R290+R600 and R600+R601 were able to expand the working limits of their pure fluids while improving COP by up to 13.5 %.
引用
收藏
页码:575 / 582
页数:8
相关论文
共 11 条
[1]  
Bergland M., 2015, INT C REFR
[2]  
Bertinat M.P., 1986, Int. J. Refrig, V9, P43
[3]   Performance analysis of different high-temperature heat pump systems for low-grade waste heat recovery [J].
Cao, Xing-Qi ;
Yang, Wei-Wei ;
Zhou, Fu ;
He, Ya-Ling .
APPLIED THERMAL ENGINEERING, 2014, 71 (01) :291-300
[4]   SELECTION OF WORKING FLUIDS FOR HIGH-TEMPERATURE HEAT-PUMPS [J].
GOKTUN, S .
ENERGY, 1995, 20 (07) :623-625
[5]   Design of a high temperature production heat pump system using geothermal water at moderate temperature [J].
Kim, Minsung ;
Baik, Young Jin ;
Park, Seong Ryong ;
Chang, Ki Chang ;
Ra, Ho Sang .
CURRENT APPLIED PHYSICS, 2010, 10 :S117-S122
[6]  
Klein S.A., 2015, ENG EQUATION SOLVER
[7]  
Stavset O, 2014, 11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014), P941
[8]  
SUESS J., 2000, INT COMPR ENG C
[9]   An analytical investigation of high-temperature heat pump system with screw compressor and screw expander for power recovery [J].
Tamura, I ;
Taniguchi, H ;
Sasaki, H ;
Yoshida, R ;
Sekiguchi, I ;
Yokogawa, M .
ENERGY CONVERSION AND MANAGEMENT, 1997, 38 (10-13) :1007-1013
[10]   Simulation of a heat pump system for total heat recovery from flue gas [J].
Wei, Maolin ;
Yuan, Weixing ;
Song, Zhijia ;
Fu, Lin ;
Zhang, Shigang .
APPLIED THERMAL ENGINEERING, 2015, 86 :326-332